1 IPv6 NetStream

1.1  IPv6 NetStream配置命令

1.1.1  display ipv6 netstream cache

display ipv6 netstream cache命令用来查看IPv6 NetStream流表项信息。

【命令】

(独立运行模式)

display ipv6 netstream cache [ verbose ] [ type { ip | ipl2 | l2 | mpls [ label-position1 label-value1 [ label-position2 label-value2 [ label-position3 label-value3 ] ] ] } ] [ destination destination-ip | destination-port destination-port | interface interface-type interface-number | protocol protocol | source source-ip | source-port source-port ] * [ arrived-time start-date start-time end-date end-time ] [ slot slot-number ]

(IRF模式)

display ipv6 netstream cache [ verbose ] [ type { ip | ipl2 | l2 | mpls [ label-position1 label-value1 [ label-position2 label-value2 [ label-position3 label-value3 ] ] ] } ] [ destination destination-ip | destination-port destination-port | interface interface-type interface-number | protocol protocol | source source-ip | source-port source-port ] * [ arrived-time start-date start-time end-date end-time ] [ chassis chassis-number slot slot-number ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

【参数】

verbose:显示IPv6 NetStream流表项的详细信息。如果未指定本参数,将显示概要信息。

type:显示的流表项类型。如果未指定本参数,则显示所有类型的流表项。

ip:显示IP流表项。

ipl2:显示二三层混合流表项。

l2:显示二层流表项。

mpls:显示MPLS流表项。

label-position1 label-value1:显示标签为指定值的MPLS流表项。label-position1表示标签位置,取值范围为1~10,其中1表示最外层标签,10表示最内层标签,以此类推。label-value1表示标签值,取值范围为0~1048575。

label-position2 label-value2:显示标签为指定值的MPLS流表项。label-position2表示标签位置,取值范围为1~10中除了已被指定过的标签位置,其中1表示最外层标签,10表示最内层标签,以此类推。label-value2表示标签值,取值范围为0~1048575。

label-position3 label-value3:显示标签为指定值的MPLS流表项。label-position3表示标签位置,取值范围为1~10中除了已被指定过的标签位置,其中1表示最外层标签,10表示最内层标签,以此类推。label-value3表示标签值,取值范围为0~1048575。

destination destination-ipv6:显示指定目的IPv6地址的所有IPv6 Netstream流表项信息,destination-ipv6用于指定IPv6地址。该参数不支持显示二层流表项。

destination-port destination-port:显示指定目的端口的所有IPv6 Netstream流表项信息,destination-port用于指定目的端口,取值范围为0~65535。该参数不支持显示二层流表项。

interface interface-type interface-number:显示指定接口的所有IPv6 Netstream流表项信息,interface-type interface-number表示接口的类型和编号。

protocol protocol:显示指定协议的所有IPv6 Netstream流表项信息,protocol用于指定协议号或者常见协议的名称,协议号的取值范围为0~255,常见协议的名称包括GRE、OSPF、TCP、UDP等。该参数不支持显示二层流表项。

source source-ipv6:显示指定源IPv6地址的所有IPv6 Netstream流表项信息,source-ipv6用于指定IPv6地址。该参数不支持显示二层流表项。

source-port source-port:显示指定源端口的所有IPv6 Netstream流表项信息,source-port用于指定源端口,取值范围为0~65535。该参数不支持显示二层流表项。

arrived-time:显示指定时间内到达的所有IPv6 Netstream流表项信息。不指定该参数时,表示对流的到达时间没有限制。

start-date:指定开始日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日),MM的取值范围为1~12,DD的取值范围与月份有关,YYYY的取值范围为2000~2035。

start-time:指定开始时间,格式为HH:MM:SS(小时:分钟:秒),HH取值范围为0~23,MM和SS取值范围为0~59。如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒。比如将start-time配置为0表示零点。

end-date:指定结束日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日),MM的取值范围为1~12,DD的取值范围与月份有关,YYYY的取值范围为2000~2035。

end-time:指定结束时间,格式为HH:MM:SS(小时:分钟:秒),HH取值范围为0~23,MM和SS取值范围为0~59。如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒。比如将end-time配置为0表示零点。

slot slot-number:指定单板。slot-number为单板所在的槽位号。如果不指定本参数,则表示指定所有单板。(独立运行模式)

chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定所有单板。(IRF模式)

【举例】

# 查看IPv6 NetStream流表项的详细信息。

<Sysname> display ipv6 netstream cache verbose

IPv6 NetStream cache information:

  Active flow timeout             : 60 min

  Inactive flow timeout           : 10 sec

  Max number of entries           : 1000

  IPv6 active flow entries        : 1

  MPLS active flow entries        : 0

  IPL2 active flow entries        : 0

  IPv6 flow entries counted       : 10

  MPLS flow entries counted       : 20

  IPL2 flow entries counted       : 20

  Last statistics resetting time  : 01/01/2000 at 00:01:02

 

IPv6 packet size distribution (1103746 packets in total):

1-32   64   96  128  160  192  224  256 288  320  352  384  416  448  480

.249 .694 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000

 

512  544  576 1024 1536 2048 2560 3072 3584 4096 4608 >4608

.000 .000 .027 .000 .027 .000 .000 .000 .000 .000 .000 .000

 

Protocol          Total Packets    Flows  Packets Active(sec) Idle(sec)

                  Flows /sec       /sec   /flow   /flow       /flow

--------------------------------------------------------------------------

TCP-Telnet      2656855     372        4       86        49        27

TCP-FTP         5900082      86        9        9        11        33

TCP-FTPD        3200453    1006        5      193        45        33

TCP-WWW       546778274   11170      887       12         8        32

TCP-other      49148540    3752       79       47        30        32

UDP-DNS       117240379     570      190        3         7        34

UDP-other      45502422    2272       73       30         8        37

ICMP           14837957     125       24        5        12        34

IP-other          77406       5        0       47        52        27

 

Type DstIP(Port)         SrcIP(Port)      Pro TC  FlowLbl If(Direct)   Pkts

     DstMAC(VLAN)        SrcMAC(VLAN)

     TopLblType(IP/MASK) Lbl-Exp-S-List

--------------------------------------------------------------------------

IP   2001::1(1024)      2002::1(21)        6   0   0x6000  XGE3/1/1(I)  42996

     TCPFlag:      27       TTL:          64

     DstMask:      24       SrcMask:      24       NextHop:      0.0.0.0

     DstAS:         0       SrcAS:         0       BGPNextHop:   0.0.0.0

     InVRF:      mvpn

     Bgp-community1:         0

     Bgp-community2:         0

     Bgp-community3:         0

     Bgp-community4:         0

     SamplerMode:Random     SamplerInt:  256

     Active:  120.600       Bytes/Pkt:   152

     First packet arrived: 10/28/2013, 14:10:03

     Last packet arrived:  10/28/2013, 14:21:03

     SRv6 policy NID:      2150629379

表1-1 display ipv6 netstream cache命令显示信息描述表

字段

描述

IPv6 NetStream cache information

IPv6 NetStream流表项信息

Active flow  timeout

活跃流的老化时间,单位为分钟

Inactive flow timeout

不活跃流的老化时间,单位为秒

Max number of entries

IPv6 NetStream流缓存区中允许的最大流数

IPv6 active flow entries

IPv6 NetStream流缓存区中活跃的IPv6流数

MPLS active flow entries

IPv6 NetStream流缓存区中活跃的MPLS流数

IPL2 active flow entries

IPv6 NetStream流缓存区中活跃的二层和三层流数

IPv6 flow entries counted

已经被统计的IPv6流数

MPLS flow entries counted

已经被统计的MPLS流数

IPL2 flow entries counted

已经被统计的二层和三层流数

Last statistics resetting time

上次清除统计的时间

该字段只在执行了reset ipv6 netstream statistics命令后才会显示为时间,否则显示为Never

IPv6 packet size distribution (1103746 packets in total):

IPv6报文按大小分布情况,括号中为IPv6报文总数。分布值按各项占报文总数的比率显示,只显示3位小数,如“.027”表示占IPv6报文总数的0.027

1-32   64   96  128  160  192  224  256  288 

320  352  384  416  448  480 512  544  576

1024 1536 2048 2560 3072 3584 4096 4608 >4608

IPv6报文尺寸区间(报文长度不包括二层链路层的头)。长度不超过576字节时,以32字节为单位递增,例如:“1-32”是长度为1~32个字节的报文数目,“64”是长度为33~64字节的报文数。长度超过1024字节时,以512字节为单位递增,例如“1536”是长度为1025~1536字节的报文数。长度为577~1024间的报文记录存放在1024项中。

Protocol     Total Flows     Packets/Sec

Flow/Sec   Packets/flow

Active(sec)/ flow   Idle(sec)/flow

按协议分类的报文统计信息:协议类型、总流数、每秒的报文数、每秒的流数、平均每条流的报文数、平均每条流的活跃时间、平均每条流的非活跃时间

Type DstIP(Port)        SrcIP(Port)        Pro TC  FlowLbl    If(Direct)   Pkts

当前流缓存区中活跃流的IP层信息: 流的类型、目的IPv6地址(目的端口号)、源IPv6地址(源端口号)、协议号、流量分类、流标签、接口名(方向)、包数

其中流的类型有四种:IP流(IP)、二三层混合流(IPL2)、不带IP选项的MPLS流(MPLS)、带IP选项的MPLS流(IP&MPLS)

需要注意的是,对于ICMPv6报文只有Type和Code字段,因此用目的端口号的高8位为Type字段、低8位为Code字段,源端口号为0

对于SRv6 TE Policy组网中,统计到SRv6 TE Policy报文的如下字段为内层原始报文的信息:DstIP(Port)、SrcIP(Port)、Pro、TC和FlowLbl

DstMAC(VLAN)          SrcMAC(VLAN)

当前流缓存区中活跃流的二层信息:目的MAC地址(目的VLAN ID)、源MAC地址(源VLAN ID)

TopLblType(IP/MASK)      Lbl-Exp-S-List

当前流缓存区中活跃流的MPLS信息,其中:

·     TopLblType:表示栈顶标签的类型

·     IP/Mask:表示栈顶标签对应的IP地址及掩码长度

·     Lbl:表示标签值,为1~20比特的字符串

·     EXP:表示报文优先级,用来实现QoS,1~3比特的字符串

·     S:栈底标识。取值为1时表示为栈底,取值为0时表示非栈底

·     List:标签列表,标签列表中至多列出三层标签,mpls-position指定标签位置

TcpFlag:    TTL:

DstMask:   SrcMask:

DstAS:       SrcAS:

NextHop:

BGPNextHop:

OutVRF:     InVRF:

Bgp-community1:

Bgp-community2:

Bgp-community3:

Bgp-community4:

SamplerMode:                  SamplerInt:

Active:       Bytes/Pkt:

First packet arrived:

Last packet arrived:

SRv6 policy NID:

当前流缓存区中活跃流的其它信息:

·     TcpFlag:TCP标记

·     TTL:生存时间

·     DstMask:目的掩码

·     SrcMask:源掩码

·     DstAS:目的自治系统

·     SrcAS:源自治系统

·     NextHop:路由下一跳

·     BGPNexthop:BGP下一跳

·     OutVRF:出方向报文转发使用的VPN

·     InVRF:入方向报文转发使用的VPN

·     Bgp-community:BGP团体属性值

·     SamplerMode:NetStream采样模式,目前支持三种:

¡     N/A:表示不采样,统计所有报文

¡     Fixed:表示固定采样

¡     Random:表示随机采样

·     SamplerInt:采样间隔

·     Active:流活跃时间

·     Bytes/Pkt:平均每个包的字节数

·     First packet arrived:该流首个报文到达时间

·     Last packet arrived:该流最后一个报文到达时间

·     SRv6 policy NID:SRv6 TE Policy的NHLFE表项索引值

对于SRv6 TE Policy组网中,通过SRv6 TE Policy报文的NetStream采样功能统计到SRv6 TE Policy L3VPN业务报文的TCPFlag、Bytes/Pkt为内层原始报文的信息,TTL、DstMask、SrcMask、DstAS、SrcAS、NextHop、BGPNextHop为外层报文的信息

对于SRv6 TE Policy组网中,通过SRv6 TE Policy报文的NetStream采样功能统计到SRv6 TE Policy L2VPN业务报文,除了TTL之外的其他字段均不支持

对于SRv6 TE Policy组网中,通过接口下的NetStream采样功能统计到SRv6 TE Policy报文的TCPFlag、Bytes/Pkt为内层原始报文的信息,DstMask、SrcMask、TTL、DstAS、SrcAS、NextHop为外层报文的信息;BGPNextHop字段不支持,显示为::

 

1.1.2  display ipv6 netstream cache archive

display ipv6 netstream cache archive命令用来查看保存到本地的IPv6 Netstream流表项信息。

【命令】

(独立运行模式)

display ipv6 netstream cache archive [ verbose ] [ type { ip | ipl2 | l2 | mpls [ label-position1 label-value1 [ label-position2 label-value2 [ label-position3 label-value3 ] ] ] } ] [ destination destination-ip | destination-port destination-port | interface interface-type interface-number | protocol protocol | source source-ip | source-port source-port ] * [ arrived-time start-date start-time end-date end-time ] [ slot slot-number ]

(IRF模式)

display ipv6 netstream cache archive [ verbose ] [ type { ip | ipl2 | l2 | mpls [ label-position1 label-value1 [ label-position2 label-value2 [ label-position3 label-value3 ] ] ] } ] [ destination destination-ip | destination-port destination-port | interface interface-type interface-number | protocol protocol | source source-ip | source-port source-port ] * [ arrived-time start-date start-time end-date end-time ] [ chassis chassis-number slot slot-number ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

【参数】

verbose:显示保存到本地的IPv6 Netstream流表项的详细信息。如果未指定本参数,将显示概要信息。

type:显示的流表项类型。如果未指定本参数,则显示所有类型的流表项。

ip:显示IP流表项。

ipl2:显示二三层混合流表项。

l2:显示二层流表项。

mpls:显示MPLS流表项。

label-position1 label-value1:显示标签为指定值的MPLS流表项。label-position1表示标签位置,取值范围为1~10,其中1表示最外层标签,10表示最内层标签,以此类推。label-value1表示标签值,取值范围为0~1048575。

label-position2 label-value2:显示标签为指定值的MPLS流表项。label-position2表示标签位置,取值范围为1~10,其中1表示最外层标签,10表示最内层标签,以此类推。label-value2表示标签值,取值范围为0~1048575。

label-position3 label-value3:显示标签为指定值的MPLS流表项。label-position3表示标签位置,取值范围为1~10,其中1表示最外层标签,10表示最内层标签,以此类推。label-value3表示标签值,取值范围为0~1048575。

destination destination-ipv6:显示指定目的IPv6地址的保存到本地的IPv6 Netstream流表项信息,destination-ipv6用于指定IPv6地址。该参数不支持显示二层流表项。

interface interface-type interface-number:显示指定接口的保存到本地的IPv6 Netstream流表项信息,interface-type interface-number表示接口的类型和编号。

source source-ipv6:显示指定源IPv6地址的保存到本地的IPv6 Netstream流表项信息,source-ipv6用于指定IPv6地址。该参数不支持显示二层流表项。

protocol protocol:显示指定协议的保存到本地的IPv6 Netstream流表项信息,protocol用于指定协议号或者常见协议的名称,协议号的取值范围为0~255,常见协议的名称包括GRE、OSPF、TCP、UDP等。该参数不支持显示二层流表项。

destination-port destination-port:显示指定目的端口的保存到本地的IPv6 Netstream流表项信息,destination-port用于指定目的端口,取值范围为0~65535。该参数不支持显示二层流表项。

source-port source-port:显示指定源端口的保存到本地的IPv6 Netstream流表项信息,source-port用于指定源端口,取值范围为0~65535。该参数不支持显示二层流表项。

arrived-time:显示指定报文到达时间范围内的保存到本地的IPv6 Netstream流表项信息。

start-date:指定时间的开始日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日),MM的取值范围为1~12,DD的取值范围与月份有关,YYYY的取值范围为2000~2035。

start-time:指定时间的开始时间,格式为HH:MM:SS(小时:分钟:秒),HH取值范围为0~23,MM和SS取值范围为0~59。如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒。比如将start-time配置为0表示零点。不指定该参数时,表示对流的到达时间没有限制。

end-date:指定时间的结束日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日),MM的取值范围为1~12,DD的取值范围与月份有关,YYYY的取值范围为2000~2035。

end-time:指定时间的结束时间,格式为HH:MM:SS(小时:分钟:秒),HH取值范围为0~23,MM和SS取值范围为0~59。如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒。比如将end-time配置为0表示零点。

slot slot-number:指定单板。slot-number为单板所在的槽位号。如果不指定本参数,则表示指定所有单板。(独立运行模式)

chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定所有单板。(IRF模式)

【举例】

# 查看2017年7月28日14:10:03到2017年7月28日14:23:03的保存到本地的IPv6 Netstream流表项信息。

<Sysname> display ipv6 netstream cache archive arrived-time 7/28/2017 14:10:03 7/28/2017 14:23:03

Type DstIP(Port)         SrcIP(Port)      Pro TC  FlowLbl  APPID  If(Direct)   Pkts

     DstMAC(VLAN)           SrcMAC(VLAN)

     TopLblType(IP/Mask)    Lbl-Exp-S-List

--------------------------------------------------------------------------

IP   2001::1(1024)       2002::1(21)      6   0   0x6000   0x0    XGE3/1/1(I)  42996

     First packet arrived: 7/28/2017, 14:20:03

     Last packet arrived:  7/28/2017, 14:21:03

1.1.3  display ipv6 netstream export

display ipv6 netstream export命令用来查看IPv6 NetStream统计输出报文的相关信息。

【命令】

(独立运行模式)

display ipv6 netstream export [ slot slot-number ]

(IRF模式)

display ipv6 netstream export [ chassis chassis-number slot slot-number ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

【参数】

slot slot-number:指定单板。slot-number为单板所在的槽位号。如果不指定本参数,则表示指定所有单板。(独立运行模式)

chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定所有单板。(IRF模式)

【使用指导】

不同的聚合方式使用不同的模板,使用该命令显示当前配置的所有聚合方式的统计输出报文的信息。

【举例】

# 查看IPv6 NetStream统计输出信息。

<Sysname> display ipv6 netstream export

as aggregation export information:

  Flow source interface                             : Ten-GigabitEthernet3/1/1

  Flow destination VPN instance                     : VPN1

  Flow destination IPv6 address (UDP)               : 40::1 (30000)

  Version  9 exported flow number                   : 16

  Version  9 exported UDP datagram number (failed)  : 2 (0)

  Version 10 exported flow number                   : 0

  Version 10 exported UDP datagram number (failed)   : 0 (0)

 

IPv6 export information:

  Flow source interface                             : Ten-GigabitEthernet3/1/1

  Flow destination VPN instance                     : VPN1

  Flow destination IPv6 address (UDP)               : 40::1 (30000)

  Version  9 exported flow number                   : 16

  Version  9 exported UDP datagram number (failed)  : 16 (0)

  Version 10 exported flow number                   : 0

  Version 10 exported UDP datagram number (failed)  : 0 (0)

表1-2 display ipv6 netstream export命令显示信息描述表

字段

描述

type export information

对应类型的IPv6 NetStream统计输出信息,type表示IPv6 NetStream统计类型

Flow source interface

输出信息的源接口

Flow destination VPN instance

输出信息的目的地址所在的VPN

Flow destination IP address (UDP)

输出信息的目的IPv4地址(UDP端口号)

Flow destination IPv6 address (UDP)

输出信息的目的IPv6地址(UDP端口号)

Version 9 exported flow number

使用版本9格式发送的流信息数

Version 9 exported UDP datagram number (failed)

使用版本9格式发送的UDP报文数(发送失败的报文数)

MPLS export information

版本9的MPLS流统计输出信息

Version 10 exported flow number

使用版本10格式发送的流信息数

Version 10 exported UDP datagram number (failed)

使用版本10格式发送的UDP报文数(发送失败的报文数)

【相关命令】

·     ipv6 netstream export host (system view)

·     ipv6 netstream export host (aggregation view)

1.1.4  display ipv6 netstream template

display ipv6 netstream template命令用来查看IPv6 NetStream模板的配置和状态信息。

【命令】

(独立运行模式)

display ipv6 netstream template [ slot slot-number ]

(IRF模式)

display ipv6 netstream template [ chassis chassis-number slot slot-number ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

【参数】

slot slot-number:指定单板。slot-number为单板所在的槽位号。如果不指定本参数,则表示指定主用主控板。(独立运行模式)

chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定Master设备主用主控板。(IRF模式)

【使用指导】

不同的聚合方式使用不同的模板,使用该命令显示当前配置的所有聚合方式的模板信息。

【举例】

# 查看IPv6 NetStream模板信息(以版本10为例)。

<Sysname> display ipv6 netstream template

 Flow template refresh frequency                : 20

 Flow template refresh interval                 : 30 min

 Active flow templates                          : 2

 Created flow templates                         : 4

 

L3 outbound template:

 Template ID                : 3282

 Packets                    : 0

 Last template export time  : Never

 Field count                : 29

 Field type                   Field length (bytes)

------------------------------------------------------------------------------

 Out packets                  8

 Out bytes                    8

 First forwarded              4

 Last forwarded               4

 Input interface index        4

 Output interface index       4

 Source IPv6 address          16

 Destination IPv6 address     16

 Next hop IPv6 address        16

 PAD                          1

 IPv6 flow label              3

 Source AS                    4

 Destination AS               4

 L4 source port               2

 L4 destination port          2

 IP protocol version          1

 TCP flags                    1

 Protocol                     1

 Source ToS                   1

 Source address mask          1

 Destination address mask     1

 Direction                    1

 Forwarding status            1

Out VPN ID                   2

 Sampling algorithm           1

 PAD                          1

 Sampling interval            4

 App ID                       4

 VPN instance name            65535

 Bgp-community1               4

 Bgp-community2               4

 Bgp-community3               4

 Bgp-community4               4

 Serial number                65535

 

L3 inbound template:

 Template ID                : 3281

 Packets                    : 0

 Last template export time  : Never

 Field count                : 29

 Field type                   Field length (bytes)

------------------------------------------------------------------------------

 In packets                   8

 In bytes                     8

 First forwarded              4

 Last forwarded               4

 Input interface index        4

 Output interface index       4

 Source IPv6 address          16

 Destination IPv6 address     16

 Next hop IPv6 address        16

 PAD                          1

 IPv6 flow label              3

 Source AS                    4

 Destination AS               4

 L4 source port               2

 L4 destination port          2

 IP protocol version          1

 TCP flags                    1

 Protocol                     1

 Source ToS                   1

 Source address mask          1

 Destination address mask     1

 Direction                    1

 Forwarding status            1

 In VPN ID                    2

 Sampling algorithm           1

 PAD                          1

 Sampling interval            4

 App ID                       4

 VPN instance name            65535

 Bgp-community1               4

 Bgp-community2               4

 Bgp-community3               4

 Bgp-community4               4

 Serial number                65535

表1-3 display ipv6 netstream template命令显示信息描述表

字段

描述

Flow template refresh frequency

模板的包刷新率

Flow template refresh interval

模板的时间刷新率,单位为分钟

Active flow templates

当前激活的模板数

Created flow templates

创建的模板总数

MPLS outbound template

MPLS出方向模板信息(仅在通过ip netstream mpls命令开启了MPLS报文统计功能的情况下才显示该模块信息)

MPLS inbound template

MPLS入方向模板信息(仅在通过ip netstream mpls命令开启了MPLS报文统计功能的情况下才显示该模块信息)

L3 outbound template

L3出方向模板信息

L3 inbound template

L3入方向模板信息

Template ID

模板ID

Packets

使用该模板的发送报文数

Last template export time

该模板最近的一次输出时间

Field count

模板的域总数

Field type

域类型

Field length (bytes)

域长度,单位为字节

Out packets

输出的数据包个数

In packets

输入的数据包个数

Out bytes

输出的数据个数,单位为字节

In bytes

输入的数据个数,单位为字节

First forwarded

记录转发第一个报文时的系统时间,时间精确到毫秒

Last forwarded

记录转发最后一个报文时的系统时间,时间精确到毫秒

Source IPv6 address

源IPv6地址

Destination IPv6 address

目的IPv6地址

Next hop IPv6 address

下一跳IPv6地址

BGP next hop IPv6 address

BGP下一跳IPv6地址,若流量没有按照BGP的路由表进行转发,则系统无法统计出BGP下一跳IPv6地址,该字段不显示

Input interface index

输入接口的索引

Output interface index

输出接口的索引

Source IPv6 address

源IPv6地址

Destination IPv6 address

目的IPv6地址

Next hop IPv6 address

下一跳IPv6地址

PAD

空白占位符

IPv6 flow label

流量标签

Source AS

源AS号

Destination AS

目的AS号

L4 source port

源端口号

L4 destination port

目的端口号

IP protocol version

IP协议版本号

TCP flags

TCP Flag

Input interface index

输入接口的索引

Output interface index

输出接口的索引

MPLS top label type

MPLS栈顶标签类型

MPLS top label IPv6 address

MPLS栈顶标签IPv6地址

MPLS top label IPv6 prefix

MPLS栈顶标签IPv6地址前缀长度

Protocol

四层协议类型

Source ToS

源服务类型

Source address mask

源地址掩码

Destination address mask

目的地址掩码

Direction

方向字段

Forwarding status

转发状态

Out VPN ID

出方向vpn索引

In VPN ID

入方向vpn索引

Sampling algorithm

采样算法

Sampling interval

采样率

App ID

应用类型

Bgp-community

BGP团体属性值(仅版本10支持)

未配置ip netstream template rfc7011时,该字段显示为Bgp-community1、Bgp-community2、Bgp-community3、Bgp-community4,字段取值长度固定为4字节;配置ip netstream template rfc7011后,该字段显示为Bgp-community,为可变长字段,最大可取65535字节

VPN instance name

VPN实例名称,公网实例显示为N/A

SRv6 policy color

SRv6 TE Policy的Color属性

SRv6 policy endpoint

SRv6 TE Policy目的节点的IPv6地址

SRv6 policy name

SRv6 TE Policy名称

Serial number

设备序列号

MPLS label n

MPLS标签位置,n取值范围为1~10,其中1表示栈顶标签,10表示第10层标签

 

1.1.5  enable

enable命令用来开启聚合视图对应的聚合功能。

undo enable命令用来关闭聚合视图对应的聚合功能。

【命令】

enable

undo enable

【缺省情况】

当前聚合视图对应的聚合功能处于关闭状态。

【视图】

IPv6 NetStream聚合视图

【缺省用户角色】

network-admin

【举例】

# 开启IPv6 NetStream的自治系统聚合功能。

<Sysname> system-view

[Sysname] ipv6 netstream aggregation as

[Sysname-ns6-aggregation-as] enable

【相关命令】

·     ipv6 netstream aggregation

1.1.6  ipv6 netstream (interface view)

ipv6 netstream命令用来在接口视图下开启IPv6 NetStream功能。

undo ipv6 netstream命令用来在接口视图下关闭IPv6 NetStream功能。

【命令】

ipv6 netstream { inbound | outbound }

undo ipv6 netstream { inbound | outbound }

【视图】

二层以太网接口视图

三层以太网接口视图

【缺省情况】

IPv6 NetStream功能处于关闭状态。

【缺省用户角色】

network-admin

【参数】

inbound:对入方向的流量进行IPv6 NetStream统计。

outbound:对出方向的流量进行IPv6 NetStream统计。

【举例】

# 在接口Ten-GigabitEthernet3/1/1的入方向上开启IPv6 NetStream功能。

<Sysname> system-view

[Sysname] interface ten-gigabitethernet 3/1/1

[Sysname-Ten-GigabitEthernet3/1/1] ipv6 netstream inbound

1.1.7  ipv6 netstream (system view)

ipv6 netstream命令用来在系统视图下开启IPv6 NetStream功能。

undo ipv6 netstream命令用来在系统视图下关闭IPv6 NetStream功能。

【命令】

ipv6 netstream

undo ipv6 netstream

【视图】

系统视图

【缺省情况】

IPv6 NetStream功能处于关闭状态。

【缺省用户角色】

network-admin

【使用指导】

本命令只能控制IPv6 NetStream流镜像中NetStream功能的开启和关闭,接口下的IPv6 NetStream功能和SRv6 TE Policy报文的IPv6 NetStream功能是否开启不受此命令的控制。

【举例】

# 在系统视图下开启IPv6 NetStream功能。

<Sysname> system-view

[Sysname] ipv6 netstream

1.1.8  ipv6 netstream aggregation

ipv6 netstream aggregation命令用来进入IPv6 NetStream聚合视图。

undo ipv6 netstream aggregation命令用来删除流聚合方式相应的配置。

【命令】

ipv6 netstream aggregation { as | bgp-nexthop | destination-prefix | prefix | protocol-port | source-prefix }

undo ipv6 netstream aggregation { as | bgp-nexthop | destination-prefix | prefix | protocol-port | source-prefix }

【缺省情况】

未配置IPv6 NetStream流聚合方式。

【视图】

系统视图

【缺省用户角色】

network-admin

【参数】

as:自治系统聚合,根据IPv6 NetStream流的源自治系统号、目的自治系统号、输入接口索引和输出接口索引4个关键项对流分类。

bgp-nexthop:边界网关-下一跳聚合,根据IPv6 NetStream流的BGP下一跳IPv6地址、输出接口索引2个关键项对流分类。

destination-prefix:目的前缀聚合,根据IPv6 NetStream流的目的自治系统号、目的掩码长度、目的前缀和输出接口索引4个关键项对流分类。

prefix:源和目的前缀聚合,根据IPv6 NetStream流的源自治系统号、目的自治系统号、源掩码长度、目的掩码长度、源前缀、目的前缀、输入接口索引和输出接口索引8个关键项对流分类。

protocol-port:协议-端口聚合,根据IPv6 NetStream流的协议号、源端口和目的端口3个关键项对流分类。

source-prefix:源前缀聚合,根据IPv6 NetStream流的源自治系统号、源掩码长度、源前缀和输入接口索引4个关键项对流分类。

【使用指导】

在聚合视图下,可以开启或关闭聚合功能,以及设置IPv6 NetStream统计输出报文源接口、目的IPv6地址以及目的端口号。

如果一条流同时满足多个聚合方式,则该流会被统计到多个聚合流中。

【举例】

# 进入IPv6 NetStream自治系统聚合视图。

<Sysname> system-view

[Sysname] ipv6 netstream aggregation as

[Sysname-ns6-aggregation-as]

【相关命令】

·     enable

·     ipv6 netstream export host

·     ipv6 netstream export source

1.1.9  ipv6 netstream cache archive enable

ipv6 netstream cache archive enable命令用来开启IPv6 NetStream流表项信息存档功能。

undo ipv6 netstream cache archive enable命令用来关闭IPv6 NetStream流表项信息存档功能。

【命令】

ipv6 netstream cache archive enable

undo ipv6 netstream cache archive enable

【缺省情况】

IPv6 NetStream流表项信息存档功能处于关闭状态。

【视图】

系统视图

【缺省用户角色】

network-admin

【使用指导】

开启本功能后,IPv6 Netstream将统计到的流表项信息保存到本地。

本功能适用于少量NetStream流表项且无日志服务器的场景,对于大量NetStream流表项的场景,开启本功能后会影响设备性能,不建议启用。

【举例】

# 开启IPv6 NetStream流表项信息存档功能。

<Sysname> system-view

[Sysname] ipv6 netstream cache archive enable

【相关命令】

·     display ipv6 netstream cache archive

1.1.10  ipv6 netstream export host (aggregation view)

ipv6 netstream export host命令用来配置IPv6 NetStream统计输出报文的目的地址和目的UDP端口号。

undo ipv6 netstream export host命令用来删除指定的目的地址或配置的所有目的地址。

【命令】

ipv6 netstream export host { ipv4-address | ipv6-address } udp-port [ vpn-instance vpn-instance-name ]

undo ipv6 netstream export host [ { ipv4-address | ipv6-address } ] [ vpn-instance vpn-instance-name ] ]

【缺省情况】

未配置IPv6 NetStream统计输出报文的目的地址和目的UDP端口号。

【视图】

IPv6 NetStream聚合视图

【缺省用户角色】

network-admin

【参数】

ipv4-address:IPv6 NetStream统计输出报文的IPv4目的地址。

ipv6-address:IPv6 NetStream统计输出报文的IPv6目的地址。

udp-port:IPv6 NetStream统计输出报文的目的UDP端口号,取值范围为0~65535。

vpn-instance vpn-instance-name:指定IPv6 NetStream统计输出报文的目的地址所属的VPN。vpn-instance-name表示MPLS L3VPN的VPN实例名称,为1~31个字符的字符串,区分大小写。如果未指定本参数,则表示IPv6 NetStream统计输出报文的目的地址位于公网中。

【使用指导】

若没有使能某类聚合功能,则无法通过display ipv6 netstream export命令查看它的相关信息(包括目的地址的目的UDP端口号)。

若聚合视图下未通过本命令配置目的地址和目的UDP端口号,则使用系统视图下的配置;若聚合视图下通过本命令配置了目的地址和目的UDP端口号,则优先使用聚合视图下的配置。

不同聚合视图下可以配置相同的目的地址和目的UDP端口号。同一个聚合视图下最多可以配置4组目的地址,设备会同时向多个已配置的目的地址发送NetStream报文,实现目的主机的备份。当多次执行本命令时:

·     如果指定的VPN参数不同,则不管IP地址和UDP端口号是否相同,均会配置成功,表示配置了不同组的目的地址。

·     如果指定的VPN参数相同或均未指定VPN参数,但IP地址不同,则均会配置成功,表示配置了不同组的目的地址。如果IP地址相同,但UDP端口号不同,则后配置的UDP端口号生效。

聚合流统计输出报文会发给聚合类型对应的聚合视图下配置的所有目的地址。

【举例】

# 配置自治系统聚合流的输出报文的目的IPv6地址为40::1,UDP端口号为5000。

<Sysname> system-view

[Sysname] ipv6 netstream aggregation as

[Sysname-ns-aggregation-as] ipv6 netstream export host 40::1 5000

【相关命令】

·     ipv6 netstream aggregation

·     ipv6 netstream export source

·     ipv6 netstream export host (system view)

·     display ipv6 netstream export

1.1.11  ipv6 netstream export host (system view)

ipv6 netstream export host命令用来配置IPv6 NetStream统计输出报文的目的地址和目的UDP端口号。

undo ipv6 netstream export host命令用来删除指定的目的地址或配置的所有目的地址。

【命令】

(独立运行模式)

ipv6 netstream export host { ipv4-address | ipv6-address } udp-port [ vpn-instance vpn-instance-name ] [ slot slot-number ]

undo ipv6 netstream export host [ {ipv4-address | ipv6-address } [ vpn-instance vpn-instance-name ] ] [ slot slot-number ]

(IRF模式)

ipv6 netstream export host { ipv4-address | ipv6-address } udp-port [ vpn-instance vpn-instance-name ] [ chassis chassis-number slot slot-number ]

undo ipv6 netstream export host [ { ipv4-address | ipv6-address } [ vpn-instance vpn-instance-name ] ] [ chassis chassis-number slot slot-number ]

【缺省情况】

未配置IPv6 NetStream统计输出报文的目的地址和目的UDP端口号。

【视图】

系统视图

【缺省用户角色】

network-admin

【参数】

ipv4-address:IPv6 NetStream统计输出报文的IPv4目的地址。

ipv6-address:IPv6 NetStream统计输出报文的IPv6目的地址。

udp-port:IPv6 NetStream统计输出报文的目的UDP端口号,取值范围为0~65535。

vpn-instance vpn-instance-name:指定IPv6 NetStream统计输出报文的目的地址所属的VPN。vpn-instance-name表示MPLS L3VPN的VPN实例名称,为1~31个字符的字符串,区分大小写。如果未指定本参数,则表示IPv6 NetStream统计输出报文的目的地址位于公网中。

slot slot-number:指定单板。slot-number为单板所在的槽位号。如果不指定本参数,则表示指定所有单板。(独立运行模式)

chassis chassis-number slot slot-number:指定单板。chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号。如果不指定本参数,则表示指定所有单板。(IRF模式)

【使用指导】

若聚合视图下未配置目的地址和目的UDP端口号,则使用系统视图下的配置;若聚合视图下配置了目的地址和目的UDP端口号,则优先使用聚合视图下的配置。

多次执行本命令(无论指定的IP地址和UDP端口号是否一样),带slot参数的配置和不带slot参数的配置都可以同时存在。对于同一单板,设备会优先采用带slot参数的配置。对于没有单独配置的单板,设备会采用不带slot参数的配置。

系统视图下最多配置4组目的地址,设备会同时向多个已配置的目的地址发送NetStream报文,实现目的主机的备份。当多次执行本命令时:

·     如果指定的VPN参数不同,则不管IP地址和UDP端口号是否相同,均会配置成功,表示配置了不同组的目的地址。

·     如果指定的VPN参数相同或均未指定VPN参数,而IP地址不同,则均会配置成功,表示配置了不同组的目的地址。如果IP地址相同,但UDP端口号不同,则后配置的UDP端口号生效。

相同slot最多指定四组目的地址。

【举例】

# 配置全局IPv6 NetStream统计输出报文的目的IPv6地址为40::1,UDP端口号为5000。

<Sysname> system-view

[Sysname] ipv6 netstream export host 40::1 5000

【相关命令】

·     ipv6 netstream aggregation

·     ipv6 netstream export source

·     ipv6 netstream export host (aggregation view)

·     display ipv6 netstream export

1.1.12  ipv6 netstream export rate

ipv6 netstream export rate命令用来配置输出速率限制。

undo ipv6 netstream export rate命令用来恢复缺省情况。

【命令】

ipv6 netstream export rate rate

undo ipv6 netstream export rate

【缺省情况】

IPv6 NetStream统计输出报文的输出速率不受限制。

【视图】

系统视图

【缺省用户角色】

network-admin

【参数】

rate:IPv6 NetStream统计输出报文的输出速率限制,取值范围为1~1000,单位为每秒最多允许输出的报文个数。

【使用指导】

配置输出速率限制,即限制每秒钟输出的报文数。

当设备每秒生成的IPv6 NetStream报文数量超过限制,设备会将这些报文保存到缓冲区稍候发送。如果设备生成IPv6 NetStream报文速率过快,会导致缓冲区被占满。此时,为避免IPv6 NetStream报文丢失,该命令将暂时失效,设备会尽力发送IPv6 NetStream报文,直到缓冲区能正常工作为止。

【举例】

# 设置每秒最多允许10个报文被输出。

<Sysname> system-view

[Sysname] ipv6 netstream export rate 10

1.1.13  ipv6 netstream export source

ipv6 netstream export source命令用来配置IPv6 NetStream统计输出报文的源接口。

undo ipv6 netstream export source命令用来恢复缺省情况。

【命令】

ipv6 netstream export source interface interface-type interface-number

undo ipv6 netstream export source

【缺省情况】

采用统计输出报文的出接口IPv6地址作为源接口的IPv6地址。

【视图】

系统视图

IPv6 NetStream聚合视图

【缺省用户角色】

network-admin

【参数】

interface-type interface-number:IPv6 NetStream统计输出报文的源接口,由接口类型和接口编号组成。

【使用指导】

通过本命令配置源接口后,会将IPv6 NetStream统计输出报文的源IPv6地址设置为该接口的IPv6地址。

不同聚合视图下可以配置不同的源接口。

聚合视图下若未配置源接口,则使用系统视图下的配置。

建议使用以太网管理接口作为源接口,与服务器相连,并向服务器输出统计信息。

【举例】

# 将全局IPv6 NetStream统计输出报文源接口设置为Ten-GigabitEthernet3/1/1。

<Sysname> system-view

[Sysname] ipv6 netstream export source interface ten-gigabitethernet 3/1/1

# 将IPv6 NetStream自治系统聚合统计输出报文源接口设置为Ten-GigabitEthernet3/1/2。

<Sysname> system-view

[Sysname] ipv6 netstream aggregation as

[Sysname-ns6-aggregation-as] ipv6 netstream export source interface ten-gigabitethernet 3/1/2

【相关命令】

·     ipv6 netstream aggregation

1.1.14  ipv6 netstream export template refresh-rate

ipv6 netstream export template refresh-rate命令用来配置IPv6 NetStream统计输出报文版本9或版本10模板的刷新率。

undo ipv6 netstream export template refresh-rate命令用来恢复缺省情况。

【命令】

ipv6 netstream export template refresh-rate { packet packets | time minutes }

undo ipv6 netstream export template refresh-rate { packet | time }

【缺省情况】

每隔20个包设备刷新一次版本9或版本10模板。

每隔30分钟设备刷新一次版本9或版本10模板。

【视图】

系统视图

【缺省用户角色】

network-admin

【参数】

packet packets:IPv6 NetStream统计输出报文版本9或版本10模板的包刷新率,取值范围为1~600,单位为包数,即每隔多少个包刷新一次模板,并通知IPv6 NetStream服务器最新的模版格式。

time minutes:IPv6 NetStream统计输出报文版本9或版本10模板的时间刷新率,取值范围为1~3600,单位为分钟,即每隔多少分钟刷新一次模板,并通知IPv6 NetStream服务器最新的模板格式。

【使用指导】

版本9和版本10是基于模板方式的、可支持自定义格式,所以设备上需要定期刷新模板,并通知IPv6 NetStream服务器最新的版本9或版本10模版格式。用户可以根据实际情况,配置版本9或版本10模板的包刷新率和时间刷新率,及时更新模板。

可以同时配置包刷新率和时间刷新率,只要满足任意一个刷新条件,设备就会将符合条件的模板发送给IPv6 NetStream服务器。

【举例】

# 将IPv6 NetStream统计输出报文版本9或版本10模板的包刷新率设为100。

<Sysname> system-view

[Sysname] ipv6 netstream export template refresh-rate packet 100

1.1.15  ipv6 netstream export version

ipv6 netstream export version 9命令用来配置IPv6 NetStream版本9的自治系统选项、BGP下一跳选项和设备序列号选项。

ipv6 netstream export version 10命令用来配置IPv6 NetStream版本10的自治系统选项、BGP下一跳选项和设备序列号选项。

undo ipv6 netstream export version命令用来恢复缺省情况。

【命令】

ipv6 netstream export version { 9 | 10 } { origin-as | peer-as } [ bgp-nexthop ] [ serial-number ]

undo ipv6 netstream export version

【缺省情况】

IPv6 NetStream统计输出报文使用版本9,记录邻接自治系统(peer-as)信息,不记录BGP下一跳信息和设备序列号选项。

【视图】

系统视图

【缺省用户角色】

network-admin

【参数】

origin-as:流信息中记录的自治系统号为起始自治系统号。

peer-as:流信息中记录的自治系统号为邻接自治系统号。

bgp-nexthop:流信息中记录BGP下一跳。

serial-number:流信息中记录设备序列号。

【使用指导】

同一时间,IPv6 Netstream只能使用一个版本输出报文,所以,多次执行本命令,最后一次执行的命令生效。

IPv6 NetStream流信息中会记录流的源IPv6地址及其对应的自治系统号;目的IPv6地址及其对应的自治系统号。设备会根据用户实际配置的自治系统参数来确定记录的自治系统号。版本9和版本10还可以配置是否记录BGP下一跳信息和设备序列号信息。

【举例】

# 将IPv6 NetStream统计采用起始自治系统号作为给定IPv6地址的自治系统号,同时记录BGP下一跳信息和设备序列号信息。

<Sysname> system-view

[Sysname] ipv6 netstream export version 9 origin-as bgp-nexthop serial-number

1.1.16  ipv6 netstream max-entry

ipv6 netstream max-entry命令用来配置IPv6 NetStream流缓存区中流表项的最大数目,或者达到流表项的最大数目时的处理方式。

undo ipv6 netstream max-entry命令用来恢复缺省情况。

【命令】

ipv6 netstream max-entry { max-entries | aging | disable-caching }

undo ipv6 netstream max-entry

【缺省情况】

IPv6 NetStream流缓存区中流表项的最大数目为2048000,达到流表项的最大数目时,强制老化部分流表项。

【视图】

系统视图

【缺省用户角色】

network-admin

【参数】

max-entries:IPv6 NetStream流缓存区中流表项的最大数目。取值范围为1024~2048000。

aging:达到流表项的最大数目时,强制老化部分流表项。

disable-caching:达到流表项的最大数目时,禁止新建流表项。

【使用指导】

max-entries参数值在各单板上单独生效,而不是各单板的总和。

多次执行ipv6 netstream max-entry max-entries命令,最后一次执行的命令生效。多次执行ipv6 netstream max-entry { aging | disable-caching }命令,最后一次执行的命令生效。

【举例】

# 设置IPv6 NetStream流缓存区中流表项的最大数目为5000。

<Sysname> system-view

[Sysname] ipv6 netstream max-entry 5000

# 设置IPv6 NetStream在达到流表项的最大数目时,禁止新建流表项。

<Sysname> system-view

[Sysname] ipv6 netstream max-entry disable-caching

# 设置IPv6 NetStream在达到流表项的最大数目时,强制老化部分流表项。

<Sysname> system-view

[Sysname] ipv6 netstream max-entry aging

1.1.17  ipv6 netstream outbound srv6-policy

ipv6 netstream outbound srv6-policy命令用来开启SRv6 TE Policy报文的IPv6 NetStream功能。

undo ipv6 netstream outbound srv6-policy命令用来关闭SRv6 TE Policy报文的IPv6 NetStream功能。

【命令】

ipv6 netstream outbound srv6-policy end-point ipv6 ipv6-address color color-value

undo ipv6 netstream outbound srv6-policy end-point ipv6 ipv6-address color color-value

【视图】

系统视图

【缺省情况】

SRv6 TE Policy报文的IPv6 NetStream功能处于关闭状态。

【缺省用户角色】

network-admin

【参数】

end-point ipv6 ipv6-address:SRv6 TE Policy目的节点的IPv6地址。

color color-value:SRv6 TE Policy的Color属性,取值范围为0~4294967295。

【使用指导】

在SRv6 TE Policy头节点上开启本功能后,将会对头节点上引流到指定SRv6 TE Policy的报文的进行IPv6 NetStream统计。有关SRv6 TE Policy的详细介绍,请参见“Segment Routing配置指导”中的“SRv6 TE Policy”。

SRv6 TE Policy报文的IPv6 NetStream统计功能开启和关闭状态,不受全局IPv6 NetStream功能是否开启的影响,只由本命令控制。

 

【举例】

# 配置对SRv6 TE Policy头节点上引流到目的节点的IPv6地址为1000::1、Color属性为10的SRv6 TE Policy报文进行IPv6 NetStream统计。

<Sysname> system-view

[Sysname] ipv6 netstream outbound srv6-policy end-point ipv6 1000::1 color 10

1.1.18  ipv6 netstream srv6 inner-packet

ipv6 netstream srv6 inner-packet命令用来开启IPv6 NetStream的SRv6封装的内层报文统计功能。

undo ipv6 netstream srv6 inner-packet命令用来关闭IPv6 NetStream的SRv6封装的内层报文统计功能。

【命令】

ipv6 netstream srv6 inner-packet

undo ipv6 netstream srv6 inner-packet

【缺省情况】

IPv6 NetStream的SRv6封装的内层报文统计功能处于开启状态。

【视图】

系统视图

【缺省用户角色】

network-admin

【使用指导】

缺省情况下,本功能处于开启状态,IPv6 NetStream会统计SRv6封装的内层数据报文的五元组(源IPv6地址、目的IPv6地址、协议号、源端口号和目的端口号)信息。

关闭本功能后,IPv6 NetStream会统计SRv6封装的外层数据报文的五元组(源IPv6地址、目的IPv6地址、协议号、源端口号和目的端口号)信息。

【举例】

# 开启IPv6 NetStream的SRv6封装的内层报文统计功能。

<Sysname> system-view

[Sysname] ipv6 netstream srv6 inner-packet

1.1.19  ipv6 netstream timeout active

ipv6 netstream timeout active命令用来配置流的活跃老化时间。

undo ipv6 netstream timeout active命令用来恢复缺省情况。

【命令】

ipv6 netstream timeout active minutes

undo ipv6 netstream timeout active

【缺省情况】

流的活跃老化时间为30分钟。

【视图】

系统视图

【缺省用户角色】

network-admin

【参数】

minutes:流的活跃老化时间,取值范围为1~60,单位为分钟。

【使用指导】

从采集到的第一个报文开始,该流在指定的时间内能被采集到,则该流属于活跃的流,指定的时间称为流的活跃老化时间。

【举例】

# 将流的活跃老化时间设置为60分钟。

<Sysname> system-view

[Sysname] ipv6 netstream timeout active 60

【相关命令】

·     ipv6 netstream timeout inactive

1.1.20  ipv6 netstream timeout inactive

ipv6 netstream timeout inactive命令用来配置流的不活跃老化时间。

undo ipv6 netstream timeout inactive命令用来恢复缺省情况。

【命令】

ipv6 netstream timeout inactive seconds

undo ipv6 netstream timeout inactive

【缺省情况】

流的不活跃老化时间为30秒。

【视图】

系统视图

【缺省用户角色】

network-admin

【参数】

seconds:流的不活跃老化时间,取值范围为10~600,单位为秒。

【使用指导】

从采集到的最后一个报文开始,该流在指定的时间内没有被采集到,则该流属于不活跃的流,指定的时间称为流的不活跃老化时间。

【举例】

# 将流的不活跃老化时间设置为60秒。

<Sysname> system-view

[Sysname] ipv6 netstream timeout inactive 60

【相关命令】

·     ipv6 netstream timeout active

1.1.21  reset ipv6 netstream statistics

reset ipv6 netstream statistics命令用来将流缓存区中所有流强制老化,输出报文信息,并清空IPv6 NetStream缓冲区的状态信息。

【命令】

reset ipv6 netstream statistics

【视图】

用户视图

【缺省用户角色】

network-admin

【使用指导】

在执行清除缓冲区中老化流的动作时,命令行会给出提示,告知用户这个动作可能要持续几分钟,在这段时间内不能统计。

【举例】

# 将流缓存区中所有流老化,并清空IPv6 NetStream缓冲区的状态信息和输出报文信息。

<Sysname> reset ipv6 netstream statistics

This process may take a few minutes.

NetStream statistic function is disabled during this process.