03-Device Management

HomeSupportReference GuidesMIB CompanionH3C S5590-EI S5130S-G FS5500-EI FS5500V2-EI S6530X Switch Series MIB Reference-6W10103-Device Management
09-POWER-ETHERNET-MIB
Title Size Download
09-POWER-ETHERNET-MIB 65.06 KB

POWER-ETHERNET-MIB

About this MIB

Use this MIB to query for and manage Power Source Equipment (PSE) working.

MIB file name

rfc3621-power-ethernet.mib

Root object

iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).powerEthernetMIB(105)

Tabular objects

pethPsePortTable

About this table

Use this table to obtain and control the power characteristics of power Ethernet ports on a PSE.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Supported

Not supported

Supported

 

Columns

The table indexes are pethPsePortGroupIndex and pethPsePortIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

pethPsePortGroupIndex (1.3.6.1.2.1.105.1.1.1.1)

not-accessible

Integer32

Integer32 (1..2147483647)

PSE port group index.

As per the MIB.

pethPsePortIndex (1.3.6.1.2.1.105.1.1.1.2)

not-accessible

Integer32

Integer32 (1..2147483647)

PSE port index.

As per the MIB.

pethPsePortAdminEnable (1.3.6.1.2.1.105.1.1.1.3)

read-write

TruthValue

true(1),
false(2)

Whether the port can provide the PSE functions.

As per the MIB.

pethPsePortPowerPairsControlAbility (1.3.6.1.2.1.105.1.1.1.4)

read-only

TruthValue

true(1),
false(2)

Capability of controlling the power pairs functionality to switch pins for sourcing power.

As per the MIB.

pethPsePortPowerPairs (1.3.6.1.2.1.105.1.1.1.5)

read-write

INTEGER

signal(1),
spare(2)

Pairs in use.

As per the MIB.

If the value of pethPsePortPowerPairsControl is true, this object is writable. A value of signal(1) means that the signal pairs (1, 2, 3, 6) only are in use. A value of spare(2) means that the spare pairs (4, 5, 7, 8) only are in use.

pethPsePortDetectionStatus (1.3.6.1.2.1.105.1.1.1.6)

read-only

INTEGER

disabled(1),
searching(2),
deliveringPower(3),
fault(4),
test(5),
otherFault(6)

Operational status of the port PD detection.

As per the MIB.

pethPsePortPowerPriority (1.3.6.1.2.1.105.1.1.1.7)

read-write

INTEGER

critical(1),
high(2),
low(3)

PSE port power priority.

As per the MIB.

pethPsePortMPSAbsentCounter (1.3.6.1.2.1.105.1.1.1.8)

read-only

Counter32

Standard MIB values

This counter is incremented when the PSE state diagram transitions directly from the POWER_ON state to the IDLE state due to tmpdo_timer_done being asserted.

As per the MIB.

pethPsePortType (1.3.6.1.2.1.105.1.1.1.9)

read-write

SnmpAdminString

OCTET STRING (0..255)

Type of powered device connected to the port.

As per the MIB.

A zero-length octet string is not supported.

pethPsePortPowerClassifications (1.3.6.1.2.1.105.1.1.1.10)

read-only

INTEGER

class0(1),
class1(2),
class2(3),
class3(4),
class4(5)

Class of the powered device by its power consumption.

As per the MIB.

This object takes effect only when the PD is being powered.

pethPsePortInvalidSignatureCounter (1.3.6.1.2.1.105.1.1.1.11)

read-only

Counter32

Standard MIB values

This counter is incremented when the PSE state diagram enters the SIGNATURE_INVALID state.

As per the MIB.

pethPsePortPowerDeniedCounter (1.3.6.1.2.1.105.1.1.1.12)

read-only

Counter32

Standard MIB values

This counter is incremented when the PSE state diagram enters the POWER_DENIED state.

As per the MIB.

pethPsePortOverLoadCounter (1.3.6.1.2.1.105.1.1.1.13)

read-only

Counter32

Standard MIB values

This counter is incremented when the PSE state diagram enters the ERROR_DELAY_OVER state.

As per the MIB.

pethPsePortShortCounter (1.3.6.1.2.1.105.1.1.1.14)

read-only

Counter32

Standard MIB values

This counter is incremented when the PSE state diagram enters the ERROR_DELAY_SHORT state.

As per the MIB.

 

pethMainPseTable

About this table

Use this table to obtain and control attributes of the main power source on a PSE device.

This table is not supported on non-default MDCs.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Supported

Not supported

Supported

 

Columns

The table index is pethMainPseGroupIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

pethMainPseGroupIndex (1.3.6.1.2.1.105.1.3.1.1.1)

not-accessible

Integer32

Integer32 (1..2147483647)

Index of the group to which a power Ethernet PSE is connected.

As per the MIB.

pethMainPsePower (1.3.6.1.2.1.105.1.3.1.1.2)

read-only

Gauge32

Gauge32 (1..65535)

Nominal power of the PSE, in watts.

As per the MIB.

pethMainPseOperStatus (1.3.6.1.2.1.105.1.3.1.1.3)

read-only

INTEGER

on(1),
off(2),
faulty(3)

Operational status of the main PSE.

As per the MIB.

pethMainPseConsumptionPower (1.3.6.1.2.1.105.1.3.1.1.4)

read-only

Gauge32

Standard MIB values

PSE power usage in watts.

As per the MIB.

pethMainPseUsageThreshold (1.3.6.1.2.1.105.1.3.1.1.5)

read-write

Integer32

Integer32 (1..99)

PSE power usage threshold.

As per the MIB.

 

pethNotificationControlTable

About this table

Use this table to control and obtain PSE notifications.

This table is not supported on non-default MDCs.

Support for operations

Create

Edit/Modify

Delete

Read

Not supported

Supported

Not supported

Supported

 

Columns

The table index is pethNotificationControlGroupIndex.

Object (OID)

Access

Syntax

Value range

Description

Implementation

pethNotificationControlGroupIndex (1.3.6.1.2.1.105.1.4.1.1.1)

not-accessible

Integer32

Standard MIB values

Index of the notification control group.

As per the MIB.

pethNotificationControlEnable (1.3.6.1.2.1.105.1.4.1.1.2)

read-write

INTEGER

true(1),
false(2)

Whether or not to enable notifications.

As per the MIB.

 

Notifications

This section contains the POWER-ETHERNET-MIB notifications.

pethPsePortOnOffNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.2.1.105.0.1

PSE port status change

Informational

N/A

N/A

ON

 

Description

This notification indicates if a PSE port is delivering or not power to the PD. It is generated when a PSE port changes its status except in the searching mode. A minimum of 500 milliseconds must elapse between notifications sent by the same object instance.

Status control

ON

MIB: Set pethNotificationControlEnable to true(1).

OFF

MIB: Set pethNotificationControlEnable to false(2).

Objects

OID (object name)

Description

Index

Type

Value range

1.3.6.1.2.1.105.1.1.1.6 (pethPsePortDetectionStatus)

PD detection status of a PSE port

N

INTEGER

disabled(1)

searching(2)

deliveringPower(3)

fault(4)

test(5)

otherFault(6)

This table does not contain indexes. For information about the index or indexes of a MIB object instance in an SNMP variable binding, see the section for that MIB object.

 

Recommended action

No action is required.

pethMainPowerUsageOnNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.2.1.105.0.2

PSE power usage threshold reached

Error

Minor

1.3.6.1.2.1.105.0.3(pethMainPowerUsageOffNotification)

ON

 

Description

This notification is generated when the PSE power usage reaches the threshold. A minimum of 500 milliseconds must elapse between notifications sent by the same object instance.

Status control

ON

MIB: Set pethNotificationControlEnable to true(1).

OFF

MIB: Set pethNotificationControlEnable to false(2).

Objects

OID (object name)

Description

Index

Type

Value range

1.3.6.1.2.1.105.1.3.1.1.4 (pethMainPseConsumptionPower)

PSE power usage

N

Gauge32

0..4294967295

 

This table does not contain indexes. For information about the index or indexes of a MIB object instance in an SNMP variable binding, see the section for that MIB object.

Recommended action

No action is required.

pethMainPowerUsageOffNotification

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.6.1.2.1.105.0.3

PSE power usage dropped below the threshold

Recovery

N/A

N/A

ON

 

Description

This notification is generated when the PSE power usage falls below the threshold. A minimum of 500 milliseconds must elapse between notifications sent by the same object instance.

Status control

ON

MIB: Set pethNotificationControlEnable to true(1).

OFF

MIB: Set pethNotificationControlEnable to false(2).

Objects

OID (object name)

Description

Index

Type

Value range

1.3.6.1.2.1.105.1.3.1.1.4 (pethMainPseConsumptionPower)

PSE power consumption

N

Gauge32

0..4294967295

 

This table does not contain indexes. For information about the index or indexes of a MIB object instance in an SNMP variable binding, see the section for that MIB object.

Recommended action

No action is required.

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网