15-IPv6 NetStream命令
本章节下载: 15-IPv6 NetStream命令 (288.35 KB)
目 录
1.1.1 display ipv6 netstream cache
1.1.2 display ipv6 netstream export
1.1.3 display ipv6 netstream template
1.1.7 ipv6 netstream ipsec raw-packet
1.1.9 ipv6 netstream aggregation
1.1.10 ipv6 netstream export host
1.1.11 ipv6 netstream export rate
1.1.12 ipv6 netstream export source
1.1.13 ipv6 netstream export v9-template refresh-rate packet
1.1.14 ipv6 netstream export v9-template refresh-rate time
1.1.15 ipv6 netstream export version 9
1.1.16 ipv6 netstream max-entry
1.1.17 ipv6 netstream timeout active
1.1.18 ipv6 netstream timeout inactive
1.1.19 reset ipv6 netstream statistics
ICG2000D/3000S/3000F/3000F-DP/5000G/5000T路由器使用集中式命令行,ICG 6000路由器使用分布式命令行。
display ipv6 netstream cache命令用来查看IPv6 NetStream流表项信息。
【命令】
集中式设备-独立运行模式:
display ipv6 netstream cache [ verbose ] [ type { ip | ipl2 | l2 | mpls [ label-position1 label-value1 [ label-position2 label-value2 [ label-position3 label-value3 ] ] ] } ] [ destination destination-ip | destination-port destination-port | interface interface-type interface-number | protocol protocol | source source-ip | source-port source-port ] * [ arrived-time start-date start-time end-date end-time ]
分布式设备-独立运行模式/集中式设备-IRF模式:
display ipv6 netstream cache [ verbose ] [ type { ip | ipl2 | l2 | mpls [ label-position1 label-value1 [ label-position2 label-value2 [ label-position3 label-value3 ] ] ] } ] [ destination destination-ip | destination-port destination-port | interface interface-type interface-number | protocol protocol | source source-ip | source-port source-port ] * [ arrived-time start-date start-time end-date end-time ] [ slot slot-number ]
分布式设备-IRF模式:
display ipv6 netstream cache [ verbose ] [ type { ip | ipl2 | l2 | mpls [ label-position1 label-value1 [ label-position2 label-value2 [ label-position3 label-value3 ] ] ] } ] [ destination destination-ip | destination-port destination-port | interface interface-type interface-number | protocol protocol | source source-ip | source-port source-port ] * [ arrived-time start-date start-time end-date end-time ] [ chassis chassis-number slot slot-number ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
verbose:显示IPv6 Netstream流表项的详细信息。如果未指定本参数,将显示概要信息。
type:显示的流表项类型。如果未指定本参数,则显示所有类型的流表项。
ip:显示IP流表项。
ipl2:显示二三层混合流表项。
l2:显示二层流表项。
mpls:显示MPLS流表项。
label-position1 label-value1:显示标签为指定值的MPLS流表项。label-position1表示标签位置,取值范围为1~6,其中1表示最外层标签,6表示最内层标签,以此类推。label-value1表示标签值,取值范围为0~1048575。
label-position2 label-value2:显示标签为指定值的MPLS流表项。label-position2表示标签位置,取值范围为1~6,其中1表示最外层标签,6表示最内层标签,以此类推。label-value2表示标签值,取值范围为0~1048575。
label-position3 label-value3:显示标签为指定值的MPLS流表项。label-position3表示标签位置,取值范围为1~6,其中1表示最外层标签,6表示最内层标签,以此类推。label-value3表示标签值,取值范围为0~1048575。
destination destination-ipv6:显示指定目的Ipv6地址的所有IPv6 Netstream流表项信息,destination-ipv6用于指定Ipv6地址。该参数不支持显示二层流表项。
destination-port destination-port:显示指定目的端口的所有IPv6 Netstream流表项信息,destination-port用于指定目的端口,取值范围为0~65535。该参数不支持显示二层流表项。
interface interface-type interface-number:显示指定接口的所有IPv6 Netstream流表项信息,interface-type interface-number表示接口的类型和编号。
protocol protocol:显示指定协议的所有IPv6 Netstream流表项信息,protocol用于指定协议号或者常见协议的名称,协议号的取值范围为0~255,常见协议的名称包括GRE、OSPF、TCP、UDP等。该参数不支持显示二层流表项。
source source-ipv6:显示指定源Ipv6地址的所有IPv6 Netstream流表项信息,source-ipv6用于指定Ipv6地址。该参数不支持显示二层流表项。
source-port source-port:显示指定源端口的所有IPv6 Netstream流表项信息,source-port用于指定源端口,取值范围为0~65535。该参数不支持显示二层流表项。
arrived-time:显示指定时间内到达的所有IPv6 Netstream流表项信息。不指定该参数时,表示对流的到达时间没有限制。
start-date:指定开始日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日),MM的取值范围为1~12,DD的取值范围与月份有关,YYYY的取值范围为2000~2035。
start-time:指定开始时间,格式为HH:MM:SS(小时:分钟:秒),HH取值范围为0~23,MM和SS取值范围为0~59。如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒。比如将start-time配置为0表示零点。
end-date:指定结束日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日),MM的取值范围为1~12,DD的取值范围与月份有关,YYYY的取值范围为2000~2035。
end-time:指定结束时间,格式为HH:MM:SS(小时:分钟:秒),HH取值范围为0~23,MM和SS取值范围为0~59。如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒。比如将end-time配置为0表示零点。
slot slot-number:显示指定单板上的信息。slot-number表示单板所在的槽位号。如果未指定本参数,将显示所有单板上的信息。(分布式设备-独立运行模式)
slot slot-number:显示指定成员设备上的信息。 slot-number表示设备在IRF中的成员编号。如果未指定本参数,将显示所有成员设备上的信息。(集中式设备-IRF模式)
chassis chassis-number slot slot-number:显示指定成员设备上指定单板上的信息。chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号。如果未指定本参数,将显示所有单板上的信息。(分布式设备-IRF模式)
【举例】
# 查看指定协议号为17的IPv6 Netstream流表项。
<Sysname> display ipv6 netstream cache protocol 17
Type DstIP(Port) SrcIP(Port) Pro ToS VNI APPID If(Direct) Pkts
DstMAC(VLAN) SrcMAC(VLAN)
TopLblType(IP/Mask) Lbl-Exp-S-List
--------------------------------------------------------------------------
IP 2010::1(1024) 2020::1(21) 17 128 10 0xe GE1/0/1(I) 42996
# 查看2017年7月28日14:19:03到2017年7月28日14:23:03到达的IPv6 Netstream流表项信息。
<Sysname> display ipv6 netstream cache arrived-time 7/28/2017 14:19:03 7/28/2017 14:23:03
Type DstIP(Port) SrcIP(Port) Pro ToS VNI If(Direct) Pkts
DstMAC(VLAN) SrcMAC(VLAN)
TopLblType(IP/Mask) Lbl-Exp-S-List
--------------------------------------------------------------------------
IP 2001::1(1024) 2002::1(21) 6 128 10 GE1/0/1(I) 42996
First packet arrived: 7/28/2017, 14:20:03
Last packet arrived: 7/28/2017, 14:21:03
MPLS LDP(3.3.3.3/24) 1:18-6-0 GE1/0/2(O) 291
2:24-6-0
3:30-6-1
First packet arrived: 7/28/2017, 14:20:01
Last packet arrived: 7/28/2017, 14:21:03
IP& 2003::1(2048) 2008::1(0) 1 0 N/A GE1/0/2(O) 10
L2 0012-3f86-e95d(0) 0012-3f86-e116(1008)
First packet arrived: 7/28/2017, 14:20:04
Last packet arrived: 7/28/2017, 14:21:03
IP& 2010::1(1024) 2002::1(21) 17 64 N/A GE1/0/3(I) 1848
MPLS LDP(4.4.4.4/24) 1:55-6-0
2:16-6-1
First packet arrived: 7/28/2017, 14:20:03
Last packet arrived: 7/28/2017, 14:23:03
# 查看IPv6 NetStream流表项的详细信息。(集中式设备-独立运行模式)
<Sysname> display ipv6 netstream cache verbose
IPv6 NetStream cache information:
Active flow timeout : 60 min
Inactive flow timeout : 10 sec
Max number of entries : 1000
IPv6 active flow entries : 1
MPLS active flow entries : 2
IPL2 active flow entries : 1
IPv6 flow entries counted : 10
MPLS flow entries counted : 20
IPL2 flow entries counted : 20
Last statistics resetting time : 01/01/2000 at 00:01:02
IPv6 packet size distribution (1103746 packets in total):
1-32 64 96 128 160 192 224 256 288 320 352 384 416 448 480
.249 .694 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000
512 544 576 1024 1536 2048 2560 3072 3584 4096 4608 >4608
.000 .000 .027 .000 .027 .000 .000 .000 .000 .000 .000 .000
Protocol Total Packets Flows Packets Active(sec) Idle(sec)
Flows /sec /sec /flow /flow /flow
--------------------------------------------------------------------------
TCP-Telnet 2656855 372 4 86 49 27
TCP-FTP 5900082 86 9 9 11 33
TCP-FTPD 3200453 1006 5 193 45 33
TCP-WWW 546778274 11170 887 12 8 32
TCP-other 49148540 3752 79 47 30 32
UDP-DNS 117240379 570 190 3 7 34
UDP-other 45502422 2272 73 30 8 37
ICMP 14837957 125 24 5 12 34
IP-other 77406 5 0 47 52 27
Type DstIP(Port) SrcIP(Port) Pro TC FlowLbl APPID If(Direct) Pkts
DstMAC(VLAN) SrcMAC(VLAN)
TopLblType(IP/MASK) Lbl-Exp-S-List
--------------------------------------------------------------------------
IP 2001::1(1024) 2002::1(21) 6 0 0x6000 0x0 GE1/0/1(I) 42996
MPLS LDP(3.3.3.3/24) 1:18-6-0 GE1/0/2(O) 291
2:24-6-0
3:30-6-1
IP& 2010::1(1024) 2020::1(67) 17 0 0x12345 0x0 GE1/0/3(I) 1848
MPLS LDP(4.4.4.4/24) 1:55-6-0
2:16-6-1
2:0-0-0
# 查看IPv6 NetStream流表项的详细信息。(分布式设备-独立运行模式)
<Sysname> display ipv6 netstream cache slot 1 verbose
IPv6 NetStream cache information:
Active flow timeout : 60 min
Inactive flow timeout : 10 sec
Max number of entries : 1000
IPv6 active flow entries : 1
MPLS active flow entries : 2
IPL2 active flow entries : 1
IPv6 flow entries counted : 10
MPLS flow entries counted : 20
IPL2 flow entries counted : 20
Last statistics resetting time : 01/01/2000 at 00:01:02
IPv6 packet size distribution (1103746 packets in total):
1-32 64 96 128 160 192 224 256 288 320 352 384 416 448 480
.249 .694 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000 .000
512 544 576 1024 1536 2048 2560 3072 3584 4096 4608 >4608
.000 .000 .027 .000 .027 .000 .000 .000 .000 .000 .000 .000
Protocol Total Packets Flows Packets Active(sec) Idle(sec)
Flows /sec /sec /flow /flow /flow
--------------------------------------------------------------------------
TCP-Telnet 2656855 372 4 86 49 27
TCP-FTP 5900082 86 9 9 11 33
TCP-FTPD 3200453 1006 5 193 45 33
TCP-WWW 546778274 11170 887 12 8 32
TCP-other 49148540 3752 79 47 30 32
UDP-DNS 117240379 570 190 3 7 34
UDP-other 45502422 2272 73 30 8 37
ICMP 14837957 125 24 5 12 34
IP-other 77406 5 0 47 52 27
Type DstIP(Port) SrcIP(Port) Pro TC FlowLbl APPID If(Direct) Pkts
DstMAC(VLAN) SrcMAC(VLAN)
TopLblType(IP/MASK)Lbl-Exp-S-List
--------------------------------------------------------------------------
IP 2001::1(1024) 2002::1(21) 6 0 0x0 0x0 ET1/1(I) 42996
TcpFlag: 0x1b
DstMask: 24 SrcMask: 24
DstAS: 0 SrcAS: 0
NextHop: 2001::2
BGPNextHop: 0:0:0:0:0:0:0:0
InVRF: mvpn
SamplerMode:Random SamplerInt: 0
Active: 120 Bytes/Pkt: 152
MPLS LDP(3.3.3.3/24) 1:18-6-0 GE1/0/2(O) 291
2:24-6-0
3:30-6-1
SamplerMode:Random SamplerInt: 0
Active: 660 Bytes/Pkt: 100
IP 2003::1(2048) 2008::1(0) 1 0 0x0 0x0 GE1/0/2(O) 10
IP& 2010::1(1024) 2020::1(67) 17 255 0x12345 0x0 GE1/0/3(I) 1848
MPLS LDP(4.4.4.4/24) 1:55-6-0
2:16-6-1
3:0-0-0
TcpFlag: 0
DstMask: 24 SrcMask: 24
DstAS: 0 SrcAS: 0
NextHop: 2020::2
BGPNextHop: 0:0:0:0:0:0:0:0
InVRF: vpn1
SamplerMode:Random SamplerInt: 0
Active: 382 Bytes/Pkt: 1426
表1-1 display ipv6 netstream cache命令显示信息描述表
字段 |
描述 |
IPv6 NetStream cache information |
IPv6 NetStream流缓存区信息 |
Active flow timeout |
活跃流的老化时间,单位为分钟 |
Inactive flow timeout |
不活跃流的老化时间,单位为秒 |
Max number of entries |
IPv6 NetStream流缓存区中允许的最大流数 |
IPv6 active flow entries |
IPv6 NetStream流缓存区中活跃的IPv6流数 |
MPLS active flow entries |
IPv6 NetStream流缓存区中活跃的MPLS流数 |
IPL2 active flow entries |
IPv6 NetStream流缓存区中活跃的二层和三层流数 |
IPv6 flow entries counted |
已经被统计的IPv6流数 |
MPLS flow entries counted |
已经被统计的MPLS流数 |
IPL2 flow entries counted |
已经被统计的二层和三层流数 |
Last statistics resetting time |
上次清除统计的时间 该字段只在执行了reset ipv6 netstream statistics命令后才会显示为时间,否则显示为Never |
IPv6 packet size distribution (1103746packets in total): |
IPv6报文按大小分布情况,括号中为IPv6报文总数。分布值按各项占报文总数的比率显示,只显示3位小数,如“.027”表示占IPv6报文总数的0.027 |
1-32 64 96 128 160 192 224 256 288 320 352 384 416 448 480 512 544 576 1024 1536 2048 2560 3072 3584 4096 4608 >4608 |
IPv6报文尺寸区间(报文长度不包括二层链路层的头)。长度不超过576字节时,以32字节为单位递增,例如:“1-32”是长度为1~32个字节的报文数目,“64”是长度为33~64字节的报文数。长度超过1024字节时,以512字节为单位递增,例如“1536”是长度为1025~1536字节的报文数。长度为577~1024间的报文记录存放在1024项中。 |
Protocol Total Flows Packets/Sec Flow/Sec Packets/flow Active(sec)/ flow Idle(sec)/flow |
按协议分类的报文统计信息:协议类型、总流数、每秒的报文数、每秒的流数、平均每条流的报文数、平均每条流的活跃时间、平均每条流的非活跃时间 |
Type DstIP(Port) SrcIP(Port) Pro TC FlowLbl APPID If(Direct) Pkts |
当前流缓存区中活跃流的IP层信息: 流的类型、目的IPv6地址(目的端口号)、源IPv6地址(源端口号)、协议号、流量分类、流标签、应用协议ID、接口名(方向)、包数 其中流的类型有四种:IP流(IP)、二三层混合流(IPL2)、不带IP选项的MPLS流(MPLS)、带IP选项的MPLS流(IP&MPLS) 需要注意的是,对于ICMPv6报文只有Type和Code字段,因此用目的端口号的高8位为Type字段、低8位为Code字段,源端口号为0 |
DstMAC(VLAN) SrcMAC(VLAN) |
当前流缓存区中活跃流的二层信息:目的MAC地址、目的VLAN ID、源MAC地址、源VLAN ID |
TopLblType(IP/MASK) Lbl-Exp-S-List |
当前流缓存区中活跃流的MPLS信息:栈顶标签的类型(栈顶标签对应的IP地址及掩码长度)、标签列表 标签主要的三部分: · 20比特的Label字段表示标签值 · 3比特的EXP字段用来实现QoS · 1比特S字段置1表示已达栈底 |
TcpFlag: DstMask: SrcMask: DstAS: SrcAS: NextHop: BGPNextHop: OutVRF: InVRF: SamplerMode: SamplerInt: Active: Bytes/Pkt: First packet arrived: Last packet arrived: |
当前流缓存区中活跃流的其它信息:TCP标记、目的掩码、源掩码、目的自治系统、源自治系统、路由下一跳、BGP下一跳、出方向报文转发使用的VPN 、入方向报文转发使用的VPN、采样模式、采样间隔、流活跃时间、平均每个包的字节数、该流首个报文到达时间、该流最后一个报文到达时间 NetStream采样模式,目前支持三种: · N/A:表示不采样,统计所有报文 · Fixed:表示固定采样 · Random:表示随机采样 |
display ipv6 netstream export命令用来查看IPv6 NetStream统计输出报文的各种信息。
【命令】
display ipv6 netstream export
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【举例】
# 查看IPv6 NetStream统计输出信息。
<Sysname> display ipv6 netstream export
as aggregation export information:
Flow source interface : GigabitEthernet1/0/1
Flow destination VPN instance : VPN1
Flow destination IP address (UDP) : 40::1 (30000)
Version 9 exported flows number : 16
Version 9 exported UDP datagrams number (failed) : 2 (0)
IPv6 export information:
Flow source interface : GigabitEthernet1/0/1
Flow destination VPN instance : VPN1
Flow destination IP address (UDP) : 40::1 (30000)
Version 9 exported flows number : 16
Version 9 exported UDP datagrams number (failed): 16 (0)
MPLS export information:
Flow source interface : GigabitEthernet1/0/1
Flow destination VPN instance : VPN1
Flow destination IP address (UDP) : 40::1 (30000)
Version 9 exported flows number : 20
Version 9 exported UDP datagrams number (failed) : 2 (0)
表1-2 display ipv6 netstream export命令显示信息描述表
字段 |
描述 |
IPv6 export information |
IPv6 NetStream统计输出信息 |
Flow source interface |
输出信息的源接口 |
Flow destination VPN instance |
输出信息的目的地址所在的VPN |
Flow destination IP address (UDP) |
输出信息的目的IP地址(UDP端口号) |
Version 9 exported flow number |
使用版本9格式发送的流信息数 |
Version 9 exported UDP datagrams number (failed) |
使用版本9格式发送的UDP报文数(发送失败的报文数) |
MPLS export information |
版本9的MPLS流统计输出信息 |
as aggregation export information |
开启自治系统聚合的版本9统计输出信息 |
display ipv6 netstream template命令用来查看IPv6 NetStream模板的配置和状态信息。
【命令】
集中式设备-独立运行模式:
display ipv6 netstream template
分布式设备-独立运行模式/集中式设备-IRF模式:
display ipv6 netstream template [ slot slot-number ]
分布式设备-IRF模式:
display ipv6 netstream template [ chassis chassis-number slot slot-number ]
【视图】
任意视图
【缺省用户角色】
network-admin
network-operator
【参数】
slot slot-number:显示指定单板上的信息。slot-number表示单板所在的槽位号。如果未指定本参数,将显示主用主控板上的信息。(分布式设备-独立运行模式)
slot slot-number:显示指定成员设备上的信息。slot-number表示设备在IRF中的成员编号。如果未指定本参数,将显示主设备上的信息。(集中式设备-IRF模式)
chassis chassis-number slot slot-number:显示指定成员设备上指定单板上的信息。chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号。如果未指定本参数,将显示全局主用主控板上的信息(分布式设备-IRF模式)
【举例】
# 查看IPv6 NetStream模板信息。
<Sysname> display ipv6 netstream template
Flow template refresh frequency : 20
Flow template refresh interval : 30 min
Active flow templates : 4
Created flow templates : 4
L3 outbound template:
Template ID : 3305
Field count : 27
Field type Field length (bytes)
---------------------------------------------------------------------------
Out packets 8
Out bytes 8
First forwarded 4
Last forwarded 4
Input Interface Index 4
Output Interface Index 4
Source IPv6 address 16
Destination IPv6 address 16
Next hop IPv6 address 16
PAD 1
IPv6 flow label 3
Source AS 4
Destination AS 4
L4 source port 2
L4 destination port 2
IP protocol version 1
TCP flags 1
Protocol 1
Source ToS 1
Source address mask 1
Destination address mask 1
Direction 1
Forwarding status 1
Out VPN ID 2
Sampling algorithm 1
PAD 1
Sampling interval 4
VPN instance name 65535
L3 inbound template:
Template ID : 3306
Field count : 27
Field type Field length (bytes)
---------------------------------------------------------------------------
In packets 8
In bytes 8
First forwarded 4
Last forwarded 4
Input Interface Index 4
Output Interface Index 4
Source IPv6 address 16
Destination IPv6 address 16
Next hop IPv6 address 16
PAD 1
IPv6 flow label 3
Source AS 4
Destination AS 4
L4 source port 2
L4 destination port 2
IP protocol version 1
TCP flags 1
Protocol 1
Source ToS 1
Source address mask 1
Destination address mask 1
Direction 1
Forwarding status 1
In VPN ID 2
Sampling algorithm 1
PAD 1
Sampling interval 4
VPN instance name 65535
AS outbound template:
Template ID : 3293
Field count : 14
Field type Field length (bytes)
---------------------------------------------------------------------------
Flows 4
Out packets 8
Out bytes 8
First forwarded 4
Last forwarded 4
Source AS 4
Destination AS 4
Input Interface Index 4
Output Interface Index 4
IP protocol version 1
Direction 1
Sampling algorithm 1
PAD 1
Sampling interval 4
AS inbound template:
Template ID : 3292
Field count : 14
Field type Field length (bytes)
---------------------------------------------------------------------------
Flows 4
In packets 8
In bytes 8
First forwarded 4
Last forwarded 4
Source AS 4
Destination AS 4
Input Interface Index 4
Output Interface Index 4
IP protocol version 1
Direction 1
Sampling algorithm 1
PAD 1
Sampling interval 4
表1-3 display ipv6 netstream template命令显示信息描述表
字段 |
描述 |
Flow template refresh frequency |
模板的包刷新率 |
Flow template refresh interval |
模板的时间刷新率,单位为分钟 |
Active flow templates |
当前激活的模板数 |
Created flow templates |
创建的模板总数 |
L3 outbound template |
L3出方向模板信息 |
L3 inbound template |
L3入方向模板信息 |
AS outbound template |
AS出方向模板信息 |
AS inbound template |
AS入方向模板信息 |
Template ID |
模板ID |
Packets |
使用该模板的发送报文数 |
Last template export time |
该模板最近的一次输出时间 |
Field count |
模板的域总数 |
Field type |
域类型 |
Field length (bytes) |
域长度,单位为字节 |
Flows |
聚合流数量 |
Out packets |
输出的数据包个数 |
In packets |
输入的数据包个数 |
Out bytes |
输出的数据个数,单位为字节 |
In bytes |
输入的数据个数,单位为字节 |
First forwarded |
记录转发第一个报文时的系统时间,时间精确到毫秒 |
Last forwarded |
记录转发最后一个报文时的系统时间,时间精确到毫秒 |
Source AS |
源AS号 |
Destination AS |
目的AS号 |
Input interface index |
输入接口的索引 |
Output interface index |
输出接口的索引 |
Direction |
方向字段 |
Sampling algorithm |
采样算法 |
PAD |
空白占位符 |
Sampling interval |
采样率 |
L4 source port |
源端口号 |
L4 destination port |
目的端口号 |
IP protocol version |
IP协议版本号 |
TCP flags |
TCP Flag |
Protocol |
四层协议类型 |
VPN instance name |
VPN实例名称,N/A表示公网实例 |
Out VNP ID |
出方向vpn索引 |
In VNP ID |
入方向vpn索引 |
Forwarding status |
转发状态 |
IP protocol version |
IP协议版本号 |
Source address mask |
源地址掩码 |
Destination address mask |
目的地址掩码 |
Source IPv6 address |
源IP地址 |
Destination IPv6 address |
目的IP地址 |
Next hop IPv6 address |
下一跳地址 |
enable命令用来开启当前聚合视图对应的聚合功能。
undo enable命令用来关闭当前聚合视图对应的聚合功能。
【命令】
enable
undo enable
【缺省情况】
当前聚合视图对应的聚合功能处于关闭状态。
【视图】
IPv6 NetStream聚合视图
【缺省用户角色】
network-admin
【举例】
# 开启IPv6 NetStream的自治系统聚合功能。
<Sysname> system-view
[Sysname] ipv6 netstream aggregation as
[Sysname-ns6-aggregation-as] enable
【相关命令】
· ipv6 netstream aggregation
ipv6 netstream命令用来开启IPv6 NetStream功能。
undo ipv6 netstream命令用来关闭NetStream功能。
【命令】
ipv6 netstream { inbound | outbound }
undo ipv6 netstream { inbound | outbound }
【缺省情况】
IPv6 NetStream功能处于关闭状态。
【视图】
接口视图
【缺省用户角色】
network-admin
【参数】
inbound:对入方向的流量进行IPv6 NetStream统计。
outbound:对出方向的流量进行IPv6 NetStream统计。
【举例】
# 在GigabitEthernet1/0/1接口的入方向上开启IPv6 NetStream功能。
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] ipv6 netstream inbound
ipv6 netstream filter命令用来配置IPv6 NetStream过滤功能,根据指定ACL规则对报文进行过滤。
undo ipv6 netstream filter命令用来恢复缺省情况。
【命令】
ipv6 netstream { inbound | outbound } filter acl ipv6-acl-number
undo ipv6 netstream { inbound | outbound } filter
【缺省情况】
IPv6 NetStream过滤功能处于关闭状态,此时统计所有IPv6报文。
【视图】
接口视图
【缺省用户角色】
network-admin
【参数】
inbound:入方向过滤,即对从当前接口收到的报文进行过滤统计。
outbound:出方向过滤,即对从当前接口发出的报文进行过滤统计。
acl ipv6-acl-number:指定IPv6基本或高级ACL的编号,取值范围为2000~2999和 3000~3999。。
【举例】
# 在接口GigabitEthernet1/0/1上配置根据规则号为2003的ACL规则进行出方向过滤。
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] ipv6 netstream outbound
[Sysname-GigabitEthernet1/0/1] ipv6 netstream outbound filter acl 2003
ipv6 netstream ipsec raw-packet命令用来开启IPv6 NetStream统计接口出方向的IPsec加密前的报文功能,并关闭IPv6 NetStream统计接口出方向的IPsec加密后的报文功能。
undo ipv6 netstream raw-packet命令用来恢复缺省情况。
【命令】
ipv6 netstream ipsec raw-packet
undo ipv6 netstream ipsec raw-packet
【缺省情况】
IPv6 NetStream统计接口出方向的IPSec加密前的报文功能处于关闭状态,IPv6 NetStream统计接口出方向的IPSec加密后的报文功能处于开启状态。
【视图】
接口视图
【缺省用户角色】
network-admin
【使用指导】
只有在接口的出方向上开启IPv6 NetStream功能后,IPv6 NetStream统计接口出方向的IPsec加密的报文功能才可以生效。
【举例】
# 在接口GigabitEthernet1/0/1上开启IPv6 NetStream统计接口出方向的IPsec加密前的报文功能,并关闭IPv6 NetStream统计接口出方向的IPsec加密后的报文功能。
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] ipv6 netstream outbound
[Sysname-GigabitEthernet1/0/1] ipv6 netstream ipsec raw-packet
ipv6 netstream sampler命令用来开启IPv6 NetStream采样功能。
undo ipv6 netstream sampler命令用来关闭IPv6 NetStream采样功能。
【命令】
ipv6 netstream [ inbound | outbound ] sampler sampler-name
undo ipv6 netstream [ inbound | outbound ] sampler
【缺省情况】
IPv6 NetStream采样功能处于关闭状态。
【视图】
接口视图
【缺省用户角色】
network-admin
【参数】
inbound:对入方向的报文进行采样。
outbound:对出方向的报文进行采样。
sampler sampler-name:采样器名称,为1~31个字符的字符串,不区分大小写。
【举例】
# 在接口GigabitEthernet1/0/1上开启IPv6 NetStream采样功能,使用名为abc的采样器对入方向的报文进行采样,Netstream根据采样结果进行报文统计。
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] ipv6 netstream inbound
[Sysname-GigabitEthernet1/0/1] ipv6 netstream inbound sampler abc
ipv6 netstream aggregation命令用来设置IPv6 NetStream流聚合方式,并进入相应的IPv6 NetStream聚合视图。如果指定的IPv6 NetStream流聚合方式已经存在,则直接进入相应的IPv6 NetStream聚合视图。
undo ipv6 netstream aggregation命令用来关闭IPv6 NetStream流聚合方式,并删除流聚合方式相应的配置。
【命令】
ipv6 netstream aggregation { as | bgp-nexthop | destination-prefix | prefix | protocol-port | source-prefix }
undo ipv6 netstream aggregation { as | bgp-nexthop | destination-prefix | prefix | protocol-port | source-prefix }
【缺省情况】
未配置IPv6 NetStream流聚合方式。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
as:自治系统聚合,根据IPv6 NetStream流的源自治系统号、目的自治系统号、输入接口索引和输出接口索引4个关键项对流分类。
bgp-nexthop:边界网关-下一跳聚合,根据IPv6 NetStream流的BGP下一跳IPv6地址、输出接口索引2个关键项对流分类。
destination-prefix:目的前缀聚合,根据IPv6 NetStream流的目的自治系统号、目的掩码长度、目的前缀和输出接口索引4个关键项对流分类。
prefix:源和目的前缀聚合,根据IPv6 NetStream流的源自治系统号、目的自治系统号、源掩码长度、目的掩码长度,源前缀、目的前缀、输入接口索引和输出接口索引8个关键项对流分类。
protocol-port:协议-端口聚合,根据IPv6 NetStream流的协议号、源端口和目的端口3个关键项对流分类。
source-prefix:源前缀聚合,根据IPv6 NetStream流的源自治系统号、源掩码长度、源前缀和输入接口索引4个关键项对流分类。
【使用指导】
在聚合视图下,可以开启或关闭聚合功能,以及设置IPv6 NetStream统计输出报文源接口、目的IPv6地址以及目的端口号。
如果一条流同时满足多个聚合方式,则该流会被统计到多个聚合流中。
【举例】
# 进入IPv6 NetStream自治系统聚合视图。
<Sysname> system-view
[Sysname] ipv6 netstream aggregation as
[Sysname-ns-aggregation-as]
【相关命令】
· enable
ipv6 netstream export host命令用来配置IPv6 NetStream统计输出报文的目的地址和目的UDP端口号。
undo ipv6 netstream export host命令用来删除已有配置。
【命令】
ipv6 netstream export host { ipv4-address | ipv6-address } udp-port [ vpn-instance vpn-instance-name ]
undo ipv6 netstream export host [ ipv4-address | ipv6-address [ vpn-instance vpn-instance-name ] ]
【缺省情况】
未配置目的地址和目的UDP端口号。
【视图】
系统视图
IPv6 NetStream聚合视图
【缺省用户角色】
network-admin
【参数】
Ipv4-address:IPv6 NetStream统计输出报文的IPv4目的地址。
Ipv6-address:IPv6 NetStream统计输出报文的IPv6目的地址。
udp-port:IPv6 NetStream统计输出报文的目的UDP端口号,取值范围为0~65535。
vpn-instance vpn-instance-name:指定IPv6 NetStream统计输出报文的目的地址所属的VPN。vpn-instance-name表示MPLS L3VPN的VPN实例名称,为1~31个字符的字符串,区分大小写。如果未指定本参数,则表示IPv6 NetStream统计输出报文的目的地址位于公网中。
【使用指导】
若没有使能某类聚合功能,则无法通过display ipv6 netstream export命令查看它的相关信息(包括目的地址的目的UDP端口号)。
执行undo ipv6 netstream export host命令时未指定地址,表示取消指定本视图下配置的所有地址。
不同聚合视图下可以配置相同的目的地址和目的UDP端口号。
若聚合视图下未配置目的地址和目的UDP端口号,则使用系统视图下的配置;若聚合视图下配置了目的地址和目的UDP端口号,则使用聚合视图下的配置。
一个视图下最多可配置4组IPv4目的地址,包括不同VPN实例。在同一视图下,若先后配置了IPv4地址相同、UDP端口号不同的目的地址,则后配置的目的地址生效。在用户配置了不同的VPN实例名称时,允许配置相同的IP地址和UDP端口号。
一个视图下最多可配置4组IPv6目的地址,包括不同VPN实例。在同一视图下,若先后配置了IPv6地址相同、UDP端口号不同的目的地址,则后配置的目的地址生效。在用户配置了不同的VPN实例名称时,允许配置相同的IPv6地址和UDP端口号。
普通流统计输出报文会发给系统视图下配置的所有目的地址。聚合流统计输出报文会发给聚合类型对应的聚合视图下配置的所有目的地址。为了减少对网络带宽的占用,可以只在聚合视图下配置ipv6 netstream export host命令,此时设备只会输出聚合流信息。
【举例】
# 配置全局IPv6 NetStream统计输出报文的目的IPv6地址为40::1,UDP端口号为5000。
<Sysname> system-view
[Sysname] ipv6 netstream export host 40::1 5000
# 配置IPv6 NetStream自治系统聚合统计输出报文的目的IPv6地址为40::1,UDP端口号为6000。
<Sysname> system-view
[Sysname] ipv6 netstream aggregation as
[Sysname-ns6-aggregation-as] ipv6 netstream export host 40::1 6000
【相关命令】
· ipv6 netstream aggregation
· ipv6 netstream export source
ipv6 netstream export rate命令用来配置输出速率限制,即限制每秒钟输出的报文数。
undo ipv6 netstream export rate命令用来恢复缺省情况。
【命令】
ipv6 netstream export rate rate
undo ipv6 netstream export rate
【缺省情况】
IPv6 NetStream统计输出报文的输出速率不受限制。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
rate:IPv6 NetStream统计输出报文的输出速率限制,取值范围为1~1000,单位为每秒最多允许输出的报文个数。
【举例】
# 设置每秒最多允许10个报文被输出。
<Sysname> system-view
[Sysname] ipv6 netstream export rate 10
ipv6 netstream export source命令用来配置IPv6 NetStream统计输出报文的源接口。
undo ipv6 netstream export source命令用来恢复缺省情况。
【命令】
ipv6 netstream export source interface interface-type interface-number
undo ipv6 netstream export source
【缺省情况】
采用统计输出报文的出接口作为源接口。
【视图】
系统视图
IPv6 NetStream聚合视图
【参数】
interface-type interface-number:IPv6 NetStream统计输出报文的源接口,由接口类型和接口编号组成。
【使用指导】
通过本命令配置源接口后,会将IPv6 NetStream统计输出报文的源IPv6地址设置为该接口的IPv6地址。
不同聚合视图下可以配置不同的源接口。
聚合视图下若未配置源接口,则使用系统视图下的配置。
建议使用以太网管理接口作为源接口,与服务器相连,并向服务器输出统计信息。
【举例】
# 将全局IPv6 NetStream统计输出报文源接口设置为GigabitEthernet1/0/1。
<Sysname> system-view
[Sysname] ipv6 netstream export source interface gigabitethernet 1/0/1
# 将IPv6 NetStream自治系统聚合统计输出报文源接口设置为GigabitEthernet1/0/2。
<Sysname> system-view
[Sysname] ipv6 netstream aggregation as
[Sysname-ns6-aggregation-as] ipv6 netstream export source interface gigabitethernet 1/0/2
【相关命令】
· ipv6 netstream aggregation
ipv6 netstream export v9-template refresh-rate packet命令用来配置IPv6 NetStream统计输出报文版本9模板的包刷新率。
undo ipv6 netstream export v9-template refresh-rate packet命令用来恢复缺省情况。
【命令】
ipv6 netstream export v9-template refresh-rate packet packets
undo ipv6 netstream export v9-template refresh-rate packet
【缺省情况】
每隔20个包设备发送一次版本9模板。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
packets:IPv6 NetStream统计输出报文版本9模板的包刷新率,取值范围为1~600,单位为上报报文的个数,即每隔多少个包发送一次模板,通知IPv6 NetStream服务器最新的版本9模版格式。
【使用指导】
版本9是基于模板方式的、可支持自定义格式,所以设备上需要定期刷新模板,并通知IPv6 NetStream服务器最新的版本9模版格式。用户可以根据实际情况,配置版本9模板的包刷新率,及时更新模板。
可以同时配置包刷新率和时间刷新率,只要满足任意一个刷新条件,设备就会将符合条件的模板发送给IPv6 NetStream服务器。
【举例】
# 将IPv6 NetStream统计输出报文版本9模板的包刷新率设为100。
<Sysname> system-view
[Sysname] ipv6 netstream export v9-template refresh-rate packet 100
【相关命令】
· ipv6 netstream export v9-template refresh-rate time
ipv6 netstream export v9-template refresh-rate time命令用来配置IPv6 NetStream统计输出报文版本9模板的时间刷新率。
undo ipv6 netstream export v9-template refresh-rate time命令用来恢复缺省情况。
【命令】
ipv6 netstream export v9-template refresh-rate time minutes
undo ipv6 netstream export v9-template refresh-rate time
【缺省情况】
每隔30分钟设备发送一次版本9模板。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
minutes:IPv6 NetStream统计输出报文版本9模板的时间刷新率,取值范围为1~3600,单位为分钟,即每隔多少分钟更新一次模板,通知NetStream服务器最新的V9模版格式。
【使用指导】
V9版本是基于模板方式的、可支持自定义格式,所以设备上需要定期刷新模板,并通知NetStream服务器最新的V9模版格式。用户可以根据实际情况,配置版本9模板的时间刷新率,及时更新模板。
可以同时配置包刷新率和时间刷新率,只要满足任意一个刷新条件,设备就会将符合条件的模板发送给IPv6 NetStream服务器。
【举例】
# 将IPv6 NetStream统计输出报文版本9模板的时间刷新率设为60分钟。
<Sysname> system-view
[Sysname] ipv6 netstream export v9-template refresh-rate time 60
【相关命令】
· ipv6 netstream export v9-template refresh-rate packet
ipv6 netstream export version 9命令用来配置IPv6 NetStream版本9的自治系统选项和BGP下一跳选项。
undo ipv6 netstream export version命令用来恢复缺省情况。
【命令】
ipv6 netstream export version 9 { origin-as | peer-as } [ bgp-nexthop ]
undo ipv6 netstream export version
【缺省情况】
IPv6普通流信息、IPv6聚合统计流信息和带IPv6选项信息的MPLS流信息都通过版本9的NetStream统计输出报文发送。流统计信息中记录邻接自治系统号(peer-as),流信息中不记录BGP下一跳地址。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
origin-as:流信息中记录的自治系统号为起始自治系统号。
peer-as:流信息中记录的自治系统号为邻接自治系统号。
bgp-nexthop:流信息中记录BGP下一跳。
【使用指导】
IPv6 NetStream流信息中会记录流的源IPv6地址及其对应的自治系统号;目的IPv6地址及其对应的自治系统号。设备会根据用户实际配置的自治系统参数来确定记录的自治系统号。
在使用ipv6 netstream export version 9配置输出版本信息时,如果未配置任何选项,则流统计信息中记录邻接自治系统号(peer-as),流信息中不记录BGP下一跳地址。
【举例】
# 将IPv6 NetStream统计采用起始自治系统号作为给定IPv6地址的自治系统号。
<Sysname> system-view
[Sysname] ipv6 netstream export version 9 origin-as
ipv6 netstream max-entry命令用来配置IPv6 NetStream流缓存区中流表项的最大数目,或者达到流表项的最大数目时的处理方式。
undo ipv6 netstream max-entry命令用来恢复缺省情况。
【命令】
ipv6 netstream max-entry max-entries
undo ipv6 netstream max-entry
【缺省情况】
IPv6 NetStream流缓存区中流表项的最大数目为10000。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
max-entries:IPv6 NetStream流缓存区中流表项的最大数目,取值范围为1000~100000。
【使用指导】
max-entries参数值在各单板上单独生效,而不是各单板的总和。(分布式设备-独立运行模式/分布式设备-IRF模式)
max-entries参数值在各成员设备上单独生效,而不是各成员设备的总和。(集中式设备-IRF模式)
多次执行本命令,最后一次执行的命令生效。
【举例】
# 设置IPv6 NetStream流缓存区中流表项的最大数目为5000。
<Sysname> system-view
[Sysname] ipv6 netstream max-entry 5000
ipv6 netstream timeout active命令用来配置流的活跃老化时间。
undo ipv6 netstream timeout active命令用来恢复缺省情况。
【命令】
ipv6 netstream timeout active minutes
undo ipv6 netstream timeout active
【缺省情况】
流的活跃老化时间为30分钟。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
minutes:流的活跃老化时间,取值范围为1~60,单位为分钟。
【使用指导】
从采集到的第一个报文开始,该流在指定的时间内能被采集到,则该流属于活跃的流,指定的时间称为流的活跃老化时间。
【举例】
# 将流的活跃老化时间设置为60分钟。
<Sysname> system-view
[Sysname] ipv6 netstream timeout active 60
【相关命令】
· ipv6 netstream timeout inactive
ipv6 netstream timeout inactive命令用来配置流的不活跃老化时间。
undo ipv6 netstream timeout inactive命令用来恢复缺省情况。
【命令】
ipv6 netstream timeout inactive seconds
undo ipv6 netstream timeout inactive
【缺省情况】
流的不活跃老化时间为30秒。
【视图】
系统视图
【缺省用户角色】
network-admin
【参数】
seconds:流的不活跃老化时间,取值范围为10~600,单位为秒。
【使用指导】
从采集到的最后一个报文开始,该流在指定的时间内没有被采集到,则该流属于不活跃的流,指定的时间称为流的不活跃老化时间。
【举例】
# 将流的不活跃老化时间设置为60秒。
<Sysname> system-view
[Sysname] ipv6 netstream timeout inactive 60
【相关命令】
· ipv6 netstream timeout active
reset ipv6 netstream statistics命令用来将流缓存区中所有流强制老化,输出报文信息,并清空IPv6 NetStream缓冲区的状态信息。
【命令】
reset ipv6 netstream statistics
【视图】
用户视图
【缺省用户角色】
network-admin
【使用指导】
在执行清除缓冲区中老化流的动作时,命令行会给出提示,告知用户这个动作可能要持续几分钟,在这段时间内不能统计。
【举例】
# 将流缓存区中所有流老化,并清空IPv6 NetStream缓冲区的状态信息和输出报文信息。
<Sysname> reset ipv6 netstream statistics
This process may take a few minutes.
NetStream statistic function is disabled during this process.
不同款型规格的资料略有差异, 详细信息请向具体销售和400咨询。H3C保留在没有任何通知或提示的情况下对资料内容进行修改的权利!