05-Layer 2 - LAN Switching

HomeSupportRoutersCR16000-F SeriesDiagnose & MaintainAlarms ReferencesH3C CR16000-F Routers Alarm Reference-R8530Pxx-6W10005-Layer 2 - LAN Switching
07-IEEE8021-CFM-MIB
Title Size Download
07-IEEE8021-CFM-MIB 44.71 KB

IEEE8021-CFM-MIB

About this MIB

Connectivity Fault Management (CFM) is the name of the feature defined in IEEE 802.1ag for end-to-end Operations, Administration and Maintenance (OAM) for Ethernet. In the Comware platform, the feature is called Connectivity Fault Detection (CFD).

CFD is an end-to-end per-VLAN link layer OAM mechanism. CFD is used for link connectivity detection, fault verification, and fault location.

This MIB defines how to implement CFD. Use this MIB to configure CFD on managed devices.

MIB file name

ieee8021-cfm.mib

Notifications

dot1agCfmFaultAlarm

Basic information

OID

Event

Type

Severity

Recovery notification

Default status

1.3.111.2.802.1.1.8.0.1

A MEP error occurs.

Informational

Warning

N/A (N/A)

ON

 

Notification triggers

This notification is sent when the MEP continuously fails.

Possible causes might include the following:

The CFD entities at the two ends have inconsistent MDs or MAs.

The CFD entities at the two ends have inconsistent CCM intervals.

The MEP ID in CCMs is not in the MEP ID on the local end.

No CCM is received upon expiration of the specified timer.

System impact

Continuity check cannot be performed. Service traffic switchover or interruption might occur.

Status control

This notification cannot be disabled.

Object

OID (object name)

Description

Index

Type

Value range

1.3.111.2.802.1.1.8.1.5.2.1.1 (dot1agCfmMdIndex)

MD index.

dot1agCfmMdIndex

Integer32

1.. 4294967295

1.3.111.2.802.1.1.8.1.6.1.1.1 (dot1agCfmMaIndex)

MA index.

dot1agCfmMaIndex

Integer32

1.. 4294967295

1.3.111.2.802.1.1.8.1.7.1.1.1 (dot1agCfmMepIdentifier)

MEP ID and ultimate index in the MEP list

dot1agCfmMdIndex

dot1agCfmMaIndex

dot1agCfmMepIdentifier

Integer32

1.. 8191

1.3.111.2.802.1.1.8.1.7.1.1.13 (dot1agCfmMepHighestPrDefect)

Detected faulty MEP.

dot1agCfmMdIndex

dot1agCfmMaIndex

dot1agCfmMepIdentifier

Dot1agCfmHighestDefectPri

none (0), defRemoteCCM (3), defErrorCCM (4), defXconCCM (5)

 

Recommended action

To resolve this issue:

1.Identify whether the CFD configuration is correct.

2.Identify whether the port and link states are normal.

3.If the issue persists, collect alarm information and configuration data, and then contact H3C Support for help.

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Intelligent Storage
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
  • Technical Blogs
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网