7 Appendix B FRUs and compatibility matrixes

For the compatibility between cards and the system software, see the release notes.

For the compatibility between cards and transceiver modules, see H3C S10500X Switch Series Cards and Transceiver Modules Compatibility Matrixes.

MPUs

You can install one MPU, or two MPUs for redundancy on the switch. When you install two MPUs, the two MPUs must be the same model.

Table 7-1 MPU specifications

MPU model

Specifications

Flash memory

NVRAM

SDRAM

Ports

Compatible device models

LSUM1SUPXD0

2 GB

1 MB

8 GB

·     1 × console port

·     1 × USB console port

·     4 × network management ports (two RJ-45 ports and two SFP ports)

·     1 × USB port

S10508X

S10508X-V

S10516X

LSUM1SUPXES0

4 GB

1 MB

8 GB

·     1 × console port

·     1 × USB console port

·     4 × network management ports (two RJ-45 ports and two SFP ports)

·     1 × USB port

·     2 × SMB coaxial clock output ports

·     2 × SMB coaxial clock input ports

·     2 × high-precision time synchronization ports (Both ports are used for input by default. When both the ports are used for input, only port 1 is valid.)

S10508X

S10508X-V

S10516X

LSUM1MPUS06XEC0

2 GB

1 MB

8 GB

·     1 × console port

·     1 × USB console port

·     4 × network management ports (two RJ-45 ports and two SFP ports)

·     1 × USB port

S10506X

LSUM1MPUS06XEB0

2 GB

1 MB

4 GB

·     1 × console port

·     1 × USB console port

·     4 × network management ports (two RJ-45 ports and two SFP ports)

·     1 × USB port

S10506X

LSUM1MPUS10XE0

2 GB

1 MB

8 GB

·     1 × console port

·     1 × USB console port

·     4 × network management ports (two RJ-45 ports and two SFP ports)

·     1 × USB port

S10510X

LSUM1MPUS10XEA0

4 GB

1 MB

4 GB

·     1 × console port

·     1 × USB console port

·     4 × network management ports (two RJ-45 ports and two SFP ports)

·     1 × USB port

S10510X

LSUM1MPUS10XEB0

4 GB

1 MB

8 GB

·     1 × console port

·     1 × USB console port

·     4 × network management ports (two RJ-45 ports and two SFP ports)

·     1 × USB port

·     8 × QSFP28 ports

S10510X

 

IMPORTANT

IMPORTANT:

·     Among the network management ports on an MPU, only port 0 is available during the startup of the switch.

·     To connect an SFP network management port on the MPUs, make sure the peer port operates at 1000 Mbps in full-duplex mode.

·     The 100GE ports on an LSUM1MPUS10XEB0 MPU can be used as IRF physical ports or network interfaces. When used as network interfaces, they can communicate only with interfaces on service modules.

·     Do not use USB extension cables to connect the USB ports on the MPUs.

 

Service modules

Restrictions and guidelines

Follow these restrictions and guidelines to use the service modules:

·     The fiber ports cannot automatically negotiate or be configured to operate in half-duplex mode. For information about the duplex mode of Ethernet interfaces, see Ethernet interface commands in H3C S10500X Interface Command Reference.

·     When you use the using hundredgige-from-fortygige interface command to convert 40-GE ports on the LSUM2CQGS12SG0 and LSUM1CQGS12XSG0 interface modules to 100-GE ports, only ports 1, 4, 7, and 10 are available.

·     When you use the using hundredgige-from-fortygige interface command to convert 40-GE ports on an LSUM1CQGS32SF0 interface module to 100-GE ports, only odd-numbered ports are available.

·     Slot 15 on an S10516X switch does not support the LSUM1CGS32XSH0 or LSUM1CGS20XSH0 interface module.

·     An S10510X switch does not support the LSUM1CGS32XSH0 or LSUM1CGS20XSH0 interface module when it uses the LSUM1MPUS10XEA0 or LSUM1MPUS10XEB0 MPUs.

·     An S10506X switch does not support the LSUM1CGS32XSH0 or LSUM1CGS20XSH0 interface module in slot 4 or 5 when it uses the LSUM1MPUS06XEB0 MPUs.

·     You can use SA interface modules on the switch only when one of the following conditions exists:

¡     The switch uses the LSUM1MPUS06XEB0, LSUM1MPUS06XEC0, LSUM1MPUS10XE0, LSUM1MPUS10XEA0, or LSUM1MPUS10XEB0 MPUs.

¡     The switch uses the LSUM1SUPXD0 or LSUM1SUPXES0 MPUs together with the LSUM1FAB08XEB0 switching fabric modules.

Ethernet interface modules

Table 7-2 Ethernet interface module specifications

Model

Port quantity

Port type

Compatible transceiver modules and network cables

LSUM1YGS24CSSH0

28

·     4 × 100GBASE-R-QSFP28 fiber ports

·     24 × 25GBASE-R-SFP28 fiber ports

·     QSFP28 transceiver module

·     QSFP28 DAC cable

·     QSFP28 AOC cable

·     QSFP+ transceiver module

·     QSFP+ DAC cable

·     QSFP+ AOC cable

·     SFP28 transceiver module

·     SFP28 DAC cable

·     SFP28 AOC cable

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

LSUM1CGS20XSH0

20

20 × 100GBASE-R-QSFP28 fiber ports

·     QSFP28 transceiver module

·     QSFP28 DAC cable

·     QSFP28 to SFP28 DAC cable

·     QSFP+ transceiver module

·     QSFP+ DAC cable

·     QSFP28 AOC cable

·     QSFP+ to SFP+ DAC cable

LSUM1CGS8QSSH0

16

·     8 × 100GBASE-R-QSFP28 fiber ports

·     8 × 40GBASE-R-QSFP+ fiber ports

·     QSFP28 transceiver module

·     QSFP28 DAC cable

·     QSFP28 AOC cable

·     QSFP28 to SFP28 DAC cable

·     QSFP+ transceiver module

·     QSFP+ DAC cable

·     QSFP+ AOC cable

·     QSFP+ to SFP+ DAC cable

LSUM1CGS8SH0

8

8 × 100GBASE-R-QSFP28 fiber ports

·     QSFP28 transceiver module

·     QSFP28 DAC cable

·     QSFP28 AOC cable

·     QSFP28 to SFP28 DAC cable

·     QSFP+ transceiver module

·     QSFP+ DAC cable

·     QSFP+ AOC cable

·     QSFP+ to SFP+ DAC cable

LSUM1CGS32XSH0

32

32 × 100GBASE-R-QSFP28 fiber ports

·     QSFP28 transceiver module

·     QSFP28 DAC cable

·     QSFP28 AOC cable

·     QSFP28 to SFP28 DAC cable

·     QSFP+ transceiver module

·     QSFP+ DAC cable

·     QSFP+ AOC cable

LSUM2CQGS12SG0

12

12 × 40G QSFP+ fiber ports or 4 × 100G QSFP28 fiber ports

·     QSFP28 transceiver module

·     QSFP+ transceiver module

·     QSFP+ DAC cable

·     QSFP+ to SFP+ DAC cable

LSUM1CQGS12XSG0

12

12 × 40G QSFP+ fiber ports or 4 × 100G QSFP28 fiber ports

·     QSFP28 transceiver module

·     QSFP+ transceiver module

·     QSFP+ DAC cable

·     QSFP+ to SFP+ DAC cable

LSUM1CQGS32SF0

32

32 × 40GBASE-R-QSFP+ fiber ports or 16 × 100GBASE-R-QSFP28 fiber ports

·     QSFP28 transceiver module

·     QSFP+ transceiver module

·     QSFP+ DAC cable

LSUM1CGS2FE0

2

2 × 100GBASE-R-QSFP28 fiber ports

QSFP28 transceiver module

LSUM2TGS32QSSG0

36

·     4 × 40GBASE-R-QSFP+ fiber ports

·     32 × 10GBASE-R-SFP+ fiber ports

·     QSFP+ transceiver module

·     QSFP+ DAC cable

·     QSFP+ to SFP+ DAC cable

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     FE/GE SFP transceiver module

LSUM2QGS24RSG0

24

24 × 40G QSFP+ fiber ports

·     QSFP+ transceiver module

·     QSFP+ DAC cable

·     QSFP+ to SFP+ DAC cable

LSUM2QGS12SG0

12

12 × 40GBASE-R-QSFP+ fiber ports

·     QSFP+ transceiver module

·     QSFP+ DAC cable

·     QSFP+ to SFP+ DAC cable

LSUM1QGS6EC0

6

6 × 40GBASE-R-QSFP+ fiber ports

QSFP+ transceiver module

LSUM1YGS48XSH0

48

48 × 25GBASE-R-SFP28 fiber ports

·     SFP28 transceiver module

·     10-GE SFP+ transceiver module

·     GE SFP transceiver module

·     SFP28 DAC cable

·     10-GE SFP+ DAC cable

·     SFP28 AOC cable

LSUM2GT24PTSSE0

48

·     4 × 10GBASE-R SFP+/LC fiber ports

·     20 × 1000BASE-X-SFP/LC fiber ports

·     24 × 10/100/1000BASE-T-RJ-45 copper ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     FE/GE SFP transceiver module

·     Category 5 twisted pair cable

LSUM2GT24TSSE0

28

·     4 × 10GBASE-R SFP+/LC fiber ports

·     24 × 10/100/1000BASE-T-RJ-45 copper ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     FE/GE SFP transceiver module

·     Category 5 twisted pair cable

LSUM1TGS48SH0

48

48 × 10GBASE-R-SFP+ fiber ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     GE SFP transceiver module

LSUM2TGS48SH0

48

48 × 10GBASE-R-SFP+ fiber ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     GE SFP transceiver module

LSUM1TGS48RSH0

48

48 × 10GBASE-R-SFP+ fiber ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     GE SFP transceiver module

LSUM1TGS48XSG0

48

48 × 10GBASE-R-SFP+ fiber ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     FE/GE SFP transceiver module

LSUM2TGS48SG0

48

48 × 10GBASE-R-SFP+ fiber ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     FE/GE SFP transceiver module

LSUM1GP40TS8FD0

48

·     8 × 10GBASE-R-SFP+ fiber ports

·     40 × 1000BASE-X-SFP fiber ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     FE/GE SFP transceiver module

LSUM2GP40TS8FD0

48

·     8 × 10GBASE-R-SFP+ fiber ports

·     40 × 1000BASE-X-SFP fiber ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     FE/GE SFP transceiver module

LSUM2GP44TSSE0

48

·     4 × 10GBASE-R SFP+/LC fiber ports

·     44 × 1000BASE-X-SFP/LC fiber ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     FE/GE SFP transceiver module

LSUM2GP24TSSE0

28

·     4 × 10GBASE-R SFP+/LC fiber ports

·     24 × 1000BASE-X-SFP/LC fiber ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     FE/GE SFP transceiver module

LSUM2GP24TSSA0

28

·     4 × 10GBASE-R/ SFP+/LC fiber ports

·     24 × 1000BASE-X-SFP/LC fiber ports

·     10-GE SFP+ transceiver module

·     FE/GE SFP transceiver module

LSUM1TGS24FD0

24

24 × 10GBASE-R-SFP+ fiber ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     FE/GE SFP transceiver module

LSUM1TGS16FD0

16

16 × 10GBASE-R-SFP+ fiber ports

·     10-GE SFP+ transceiver module

·     10-GE SFP+ DAC cable

·     FE/GE SFP transceiver module

LSUM1TGS24EC0

24

24 × 10GBASE-R-SFP+ fiber ports

·     10-GE SFP+ transceiver module

·     FE/GE SFP transceiver module

LSUM1GP48FD0

48

48 × 1000BASE-X-SFP fiber ports

FE/GE SFP transceiver module

LSUM2GP48SA0

48

48 × 1000BASE-X-SFP/LC fiber ports

FE/GE SFP transceiver module

LSUM1TGT24FD0

24

10GBASE-T-RJ-45 copper port

Category 6A/7 twisted pair cable

LSUM1GT48FD0

48

48 × 10/100/1000BASE-T-RJ-45 copper ports

Category 5 twisted pair cable

LSUM2GT48SE0

48

48 × 10/100/1000BASE-T-RJ-45 copper ports

Category 5 twisted pair cable

LSUM2GT48SA0

48

48 × 10/100/1000BASE-T-RJ-45 copper ports

Category 5 twisted pair cable

 

OAA modules

Table 7-3 OAA module specifications

Model

Description

Ports

Compatible transceiver modules

LSUM1WCMX20RT

Access controller module

·     1 × console port

·     1 × 100/1000BASE-T out-of-band management Ethernet port

Category 5 twisted pair cable

LSUM1WCMX40RT

Access controller module

·     1 × console port

·     1 × 100/1000BASE-T out-of-band management Ethernet port

Category 5 twisted pair cable

LSUM1FWDEC0

Firewall module

·     1 × console port

·     1 × USB port (reserved)

·     1 × GE copper port

·     1 × hard disk slot

Category 5 twisted pair cable

LSUM1NSDEC0

NetStream module

·     1 × console port

·     1 × USB port (reserved)

·     1 × GE copper port

·     1 × hard disk slot

Category 5 twisted pair cable

LSUM1ACGDEC0

Application control gateway module

·     1 × console port

·     1 × USB port (reserved)

·     1 × 10/100/1000BASE-T copper port

·     1 × hard disk slot

Category 5 twisted pair cable

LSUM1EPSB0

EPS endpoint security module

·     3 × USB 2.0 ports (used only by technical personnel for debugging)

·     1 × VGA connector

·     1 × 10/100/1000BASE-T management Ethernet port

·     1 × console port (used only by technical personnel for debugging)

Category 5 twisted-pair cable

LSUM1SDNB0

SDN automation module

·     3 × USB 2.0 ports (used only by technical personnel for debugging)

·     1 × VGA connector

·     1 × 10/100/1000BASE-T management Ethernet port

·     1 × console port (used only by technical personnel for debugging)

Category 5 twisted-pair cable

LSUM1WBCZ720XRT

Multiservice access controller module

·     3 × USB 2.0 ports (only for debugging use)

·     1 × VGA connector

·     1 × 1000BASE-T management Ethernet port

·     1 × console port

Category 5 twisted-pair cable

 

Switching fabric modules

CAUTION

CAUTION:

·     The console port on a switching fabric module is only for maintenance by H3C Support. Do not use the port if you have not been trained for that.

·     You must install switching fabric modules of the same model on the switch.

 

IMPORTANT

IMPORTANT:

Follow these restrictions and guidelines when you install switching fabric modules:

·     On an S10506X switch, populate switching fabric module slots 9 and 10 prior to slot 7. Populate slot 7 only when the switch requires three switching fabric modules.

·     On an S10508X or S10508X-V switch, populate switching fabric module slots 10 and 12 prior to other switching fabric module slots. Populate slot 11 only when the switch requires five switching fabric modules.

·     On an S10510X switch, populate switching fabric module slots 13 and 14 prior to slot 11. Populate slot 11 only when the switch requires three switching fabric modules.

·     Do not install both an LSUM1FAB10XE0 switching fabric module and an LSUM1MPUS10XEB0 MPU on an S10510X switch.

·     On an S10516X switch, populate switching fabric module slots 18 and 20 prior to other switching fabric module slots. Populate slot 19 only when the switch requires five switching fabric modules.

 

Table 7-4 Compatibility between switching fabric modules and switch models

Switch model

Compatible switching fabric modules

Quantity

S10506X

·     LSUM1FAB06XEC0

·     LSUM1FAB06XEB0

0 to 3

S10508X

·     LSUM1FAB08XE0

·     LSUM1FAB08XEB0

2 to 5

S10508X-V

·     LSUM1FAB08XE0

·     LSUM1FAB08XEB0

2 to 5

S10510X

·     LSUM1FAB10XE0

·     LSUM1FAB10XEA0

0 to 3

S10516X

LSUM1FAB16XD0

2 to 5

 

All the switching fabric modules in Table 7-4 except the LSUM1FAB16XD0 each provide an RJ-45 console port.

Power system

Power modules

CAUTION

CAUTION:

Do not install power modules of different models on the same switch.

 

The LSUM1AC1200 and LSUM2AC2500 AC power modules and the LSUM1DC2400 DC power module are available for the switch.

Table 7-5 Power module specifications

Item

LSUM1AC1200

LSUM1AC2500

LSUM1DC2400

Rated input voltage range

100 VAC to 240 VAC @ 50/60 Hz

100 VAC to 240 VAC @ 50/60 Hz

–48 VDC to –60 VDC

Rated output voltage

12 VDC

12 VDC

12 VDC

Maximum input current

16 A

16 A

60 A

Maximum output current

100 A

·     208 A (220 VAC)

·     100 A (110 VAC)

200 A

Maximum output power

1200 W

·     1200 W (110 VAC)

·     2500 W (220 VAC)

2400 W

Temperature requirements

·     Operating temperature: –10°C to +50°C (14°F to 122°F)

·     Storage temperature: –40°C to +70°C (–40°F to +185°F)

·     Operating temperature: –10°C to +50°C (14°F to 122°F)

·     Storage temperature: –40°C to +70°C (–40°F to +185°F)

·     Operating temperature: –10°C to +50°C (14°F to 122°F)

·     Storage temperature: –40°C to +70°C (–40°F to +185°F)

Applicable switch models

·     S10506X

·     S10508X

·     S10508X-V

·     S10510X

All S10500X models

All S10500X models

Quantity

·     S10506X: 1 to 4

·     S10508X/S10508X-V/S10510X: 1 to 6

·     S10506X: 1 to 4

·     S10508X/S10508X-V/S10510X: 1 to 6

·     S10516X: 1 to 16

·     S10506X: 1 to 4

·     S10508X/S10508X-V/S10510X: 1 to 6

·     S10516X: 1 to 16

 

Make sure the total maximum output power of the ordered power modules is greater than the system power consumption. As a best practice, reserve 20% of the maximum output power.

 

 

NOTE:

When the temperature of a power module exceeds the acceptable temperature range, the power module is automatically powered off. When the temperature returns to the acceptable temperature range, the power module is automatically powered on.

 

Power cords

DC power cords

DC power cords are used for connecting DC power modules of the switch to the external DC power source.

Table 7-6 DC power cords available for S10500X switches

Chassis model

DC power cord quantity

Cord code and length

Remarks

S10506X

1 to 4 pairs

·     0404A0E1, 3 m (9.84 ft)

·     0404A0E2, 15 m (49.21 ft)

 

S10508X

1 to 6 pairs

·     0404A0E1, 3 m (9.84 ft)

·     0404A0E2, 15 m (49.21 ft)

Used for connecting the LSUM1DC2400 power module to a DC power source

S10508X-V

1 to 6 pairs

·     0404A0E1, 3 m (9.84 ft)

·     0404A0E2, 15 m (49.21 ft)

S10510X

1 to 6 pairs

·     0404A0E1, 3 m (9.84 ft)

·     0404A0E2, 15 m (49.21 ft)

S10508X-V

1 to 16 pairs

·     0404A0E1, 3 m (9.84 ft)

·     0404A0E2, 15 m (49.21 ft)

 

AC power cords

An AC power cord is used to connect an AC power module of the switch to the external AC power supply system.

To select an AC power cord for an AC power module, consider the following items:

·     Power capacity of the power module.

·     Current-carrying capacity of the power cord.

·     Region-and country-specific plug type.

The AC power modules available for the switch require a 16A AC power cord. Table 7-7 describes the region-and country-specific plug types for 16A AC power cords.

Table 7-7 16A AC power cords used in different countries or regions

1

Plug type

Code (Length)

Countries or regions where the type of power cords conforms to local safety regulations and can be used legally

Other countries or regions using this type of power cords

Countries or regions seldom using this type of power cords

I type

04043396 (3 m, or 9.8 ft)

Mainland China

N/A

N/A

Plug outline

Power cord outline

Connector outline

040433961WX_VD

2

Plug type

Code (Length)

Countries or regions where the type of power cords conforms to local safety regulations and can be used legally

Other countries or regions using this type of power cords

Countries or regions seldom using this type of power cords

C20 type

0404A0C2 (3 m, or 9.8 ft)

Mainland China

N/A

N/A

Plug outline

Power cord outline

Connector outline

3

Plug type

Code (Length)

Countries or regions where the type of power cords conforms to local safety regulations and can be used legally

Other countries or regions using this type of power cords

Countries or regions seldom using this type of power cords

B type

0404A063 (3 m, or 9.8 ft)

Canada and U.S.A

Mexico, Argentina, Brazil, Columbia, Venezuela, Thailand, Peru, Philippine, and A6 countries or regions

N/A

Plug outline

Power cord outline

Connector outline

4

Plug type

Code (Length)

Countries or regions where the type of power cords conforms to local safety regulations and can be used legally

Other countries or regions using this type of power cords

Countries or regions seldom using this type of power cords

F type

0404A061 (3 m, or 9.8 ft)

Holland, Denmark, Sweden, Finland, Norway, Germany, France, Austria, Belgium, and Italy

Indonesia, Turkey, Russia, and CIS

N/A

Plug outline

Power cord outline

Connector outline

0404A0611WX_V00

0404A061WX_V00

040433961WX_VD

5

Plug type

Code (Length)

Countries or regions where the type of power cords conforms to local safety regulations and can be used legally

Other countries or regions using this type of power cords

Countries or regions seldom using this type of power cords

B type

0404A062 (3 m, or 9.8 ft)

Japan

N/A

N/A

Plug outline

Power cord outline

Connector outline

0404A062WX_V00

040433961WX_VD

6

Plug type

Code (Length)

Countries or regions where the type of power cords conforms to local safety regulations and can be used legally

Other countries or regions using this type of power cords

Countries or regions seldom using this type of power cords

I type

0404A01A (3 m, or 9.8 ft)

Australia

N/A

N/A

Plug outline

Power cord outline

Connector outline

0404A01AWX_V00

0404A01A1WX_V00

040433961WX_VD

 

 

NOTE:

The connector outline figures shown in the table are C19 straight connectors.

 

Fan trays

The S10506X, S10508X, S10508X-V, and S10510X switches come with a fan tray installed in the FAN0 slot. You can install a fan tray in the FAN1 slot as required. The S10516X switch comes with a fan tray installed in each fan tray slot.

If a fan tray fails, purchase a fan tray compatible with the switch to replace the failed one.

Table 7-8 Fan tray specifications

Fan tray

Number of fans

Fan diameter

Maximum air flow rate

S10506X master fan tray

6

120 mm (4.72 in)

680 CFM

S10506X standby fan tray

2

120 mm (4.72 in)

200 CFM

S10508X master fan tray

8

120 mm (4.72 in)

920 CFM

S10508X standby fan tray

2

120 mm (4.72 in)

200 CFM

S10508X-V fan tray

12

120 mm (4.72 in)

840 CFM

S10510X master fan tray

10

120 mm (4.72 in)

980 CFM

S10510X standby fan tray

2

120 mm (4.72 in)

260 CFM

S10516X fan tray

2

80 mm (3.15 in)

350 CFM

 

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become a Partner
  • Partner Resources
  • Partner Business Management
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网