Title | Size | Download |
---|---|---|
07-Appendix B FRUs and Compatibility Matrixes | 152.76 KB |
7 Appendix B FRUs and compatibility matrixes
For the compatibility between cards and the system software, see the release notes.
For the compatibility between cards and transceiver modules, see H3C S10500X Switch Series Cards and Transceiver Modules Compatibility Matrixes.
MPUs
MPU model |
Specifications |
||||
Flash memory |
NVRAM |
SDRAM |
Ports |
Compatible device models |
|
LSUM1SUPXD0 |
2 GB |
1 MB |
8 GB |
· 1 × console port · 1 × USB console port · 4 × network management ports (two RJ-45 ports and two SFP ports) · 1 × USB port |
S10508X S10508X-V S10516X |
LSUM1SUPXES0 |
4 GB |
1 MB |
8 GB |
· 1 × console port · 1 × USB console port · 4 × network management ports (two RJ-45 ports and two SFP ports) · 1 × USB port · 2 × SMB coaxial clock output ports · 2 × SMB coaxial clock input ports · 2 × high-precision time synchronization ports (Both ports are used for input by default. When both the ports are used for input, only port 1 is valid.) |
S10508X S10508X-V S10516X |
LSUM1MPUS06XEC0 |
2 GB |
1 MB |
8 GB |
· 1 × console port · 1 × USB console port · 4 × network management ports (two RJ-45 ports and two SFP ports) · 1 × USB port |
S10506X |
LSUM1MPUS06XEB0 |
2 GB |
1 MB |
4 GB |
· 1 × console port · 1 × USB console port · 4 × network management ports (two RJ-45 ports and two SFP ports) · 1 × USB port |
S10506X |
LSUM1MPUS10XE0 |
2 GB |
1 MB |
8 GB |
· 1 × console port · 1 × USB console port · 4 × network management ports (two RJ-45 ports and two SFP ports) · 1 × USB port |
S10510X |
LSUM1MPUS10XEA0 |
4 GB |
1 MB |
4 GB |
· 1 × console port · 1 × USB console port · 4 × network management ports (two RJ-45 ports and two SFP ports) · 1 × USB port |
S10510X |
LSUM1MPUS10XEB0 |
4 GB |
1 MB |
8 GB |
· 1 × console port · 1 × USB console port · 4 × network management ports (two RJ-45 ports and two SFP ports) · 1 × USB port · 8 × QSFP28 ports |
S10510X |
IMPORTANT: · Among the network management ports on an MPU, only port 0 is available during the startup of the switch. · To connect an SFP network management port on the MPUs, make sure the peer port operates at 1000 Mbps in full-duplex mode. · The 100GE ports on an LSUM1MPUS10XEB0 MPU can be used as IRF physical ports or network interfaces. When used as network interfaces, they can communicate only with interfaces on service modules. · Do not use USB extension cables to connect the USB ports on the MPUs. |
Service modules
Restrictions and guidelines
Follow these restrictions and guidelines to use the service modules:
· The fiber ports cannot automatically negotiate or be configured to operate in half-duplex mode. For information about the duplex mode of Ethernet interfaces, see Ethernet interface commands in H3C S10500X Interface Command Reference.
· When you use the using hundredgige-from-fortygige interface command to convert 40-GE ports on the LSUM2CQGS12SG0 and LSUM1CQGS12XSG0 interface modules to 100-GE ports, only ports 1, 4, 7, and 10 are available.
· When you use the using hundredgige-from-fortygige interface command to convert 40-GE ports on an LSUM1CQGS32SF0 interface module to 100-GE ports, only odd-numbered ports are available.
· Slot 15 on an S10516X switch does not support the LSUM1CGS32XSH0 or LSUM1CGS20XSH0 interface module.
· An S10510X switch does not support the LSUM1CGS32XSH0 or LSUM1CGS20XSH0 interface module when it uses the LSUM1MPUS10XEA0 or LSUM1MPUS10XEB0 MPUs.
· An S10506X switch does not support the LSUM1CGS32XSH0 or LSUM1CGS20XSH0 interface module in slot 4 or 5 when it uses the LSUM1MPUS06XEB0 MPUs.
· You can use SA interface modules on the switch only when one of the following conditions exists:
¡ The switch uses the LSUM1MPUS06XEB0, LSUM1MPUS06XEC0, LSUM1MPUS10XE0, LSUM1MPUS10XEA0, or LSUM1MPUS10XEB0 MPUs.
¡ The switch uses the LSUM1SUPXD0 or LSUM1SUPXES0 MPUs together with the LSUM1FAB08XEB0 switching fabric modules.
Ethernet interface modules
Table 7-2 Ethernet interface module specifications
Model |
Port quantity |
Port type |
Compatible transceiver modules and network cables |
LSUM1YGS24CSSH0 |
28 |
· 4 × 100GBASE-R-QSFP28 fiber ports · 24 × 25GBASE-R-SFP28 fiber ports |
· QSFP28 transceiver module · QSFP28 DAC cable · QSFP28 AOC cable · QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ AOC cable · SFP28 transceiver module · SFP28 DAC cable · SFP28 AOC cable · 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable |
LSUM1CGS20XSH0 |
20 |
20 × 100GBASE-R-QSFP28 fiber ports |
· QSFP28 transceiver module · QSFP28 DAC cable · QSFP28 to SFP28 DAC cable · QSFP+ transceiver module · QSFP+ DAC cable · QSFP28 AOC cable · QSFP+ to SFP+ DAC cable |
LSUM1CGS8QSSH0 |
16 |
· 8 × 100GBASE-R-QSFP28 fiber ports · 8 × 40GBASE-R-QSFP+ fiber ports |
· QSFP28 transceiver module · QSFP28 DAC cable · QSFP28 AOC cable · QSFP28 to SFP28 DAC cable · QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ AOC cable · QSFP+ to SFP+ DAC cable |
LSUM1CGS8SH0 |
8 |
8 × 100GBASE-R-QSFP28 fiber ports |
· QSFP28 transceiver module · QSFP28 DAC cable · QSFP28 AOC cable · QSFP28 to SFP28 DAC cable · QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ AOC cable · QSFP+ to SFP+ DAC cable |
LSUM1CGS32XSH0 |
32 |
32 × 100GBASE-R-QSFP28 fiber ports |
· QSFP28 transceiver module · QSFP28 DAC cable · QSFP28 AOC cable · QSFP28 to SFP28 DAC cable · QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ AOC cable |
LSUM2CQGS12SG0 |
12 |
12 × 40G QSFP+ fiber ports or 4 × 100G QSFP28 fiber ports |
· QSFP28 transceiver module · QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ to SFP+ DAC cable |
LSUM1CQGS12XSG0 |
12 |
12 × 40G QSFP+ fiber ports or 4 × 100G QSFP28 fiber ports |
· QSFP28 transceiver module · QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ to SFP+ DAC cable |
LSUM1CQGS32SF0 |
32 |
32 × 40GBASE-R-QSFP+ fiber ports or 16 × 100GBASE-R-QSFP28 fiber ports |
· QSFP28 transceiver module · QSFP+ transceiver module · QSFP+ DAC cable |
LSUM1CGS2FE0 |
2 |
2 × 100GBASE-R-QSFP28 fiber ports |
QSFP28 transceiver module |
LSUM2TGS32QSSG0 |
36 |
· 4 × 40GBASE-R-QSFP+ fiber ports · 32 × 10GBASE-R-SFP+ fiber ports |
· QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ to SFP+ DAC cable · 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSUM2QGS24RSG0 |
24 |
24 × 40G QSFP+ fiber ports |
· QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ to SFP+ DAC cable |
LSUM2QGS12SG0 |
12 |
12 × 40GBASE-R-QSFP+ fiber ports |
· QSFP+ transceiver module · QSFP+ DAC cable · QSFP+ to SFP+ DAC cable |
LSUM1QGS6EC0 |
6 |
6 × 40GBASE-R-QSFP+ fiber ports |
QSFP+ transceiver module |
LSUM1YGS48XSH0 |
48 |
48 × 25GBASE-R-SFP28 fiber ports |
· SFP28 transceiver module · 10-GE SFP+ transceiver module · GE SFP transceiver module · SFP28 DAC cable · 10-GE SFP+ DAC cable · SFP28 AOC cable |
LSUM2GT24PTSSE0 |
48 |
· 4 × 10GBASE-R SFP+/LC fiber ports · 20 × 1000BASE-X-SFP/LC fiber ports · 24 × 10/100/1000BASE-T-RJ-45 copper ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module · Category 5 twisted pair cable |
LSUM2GT24TSSE0 |
28 |
· 4 × 10GBASE-R SFP+/LC fiber ports · 24 × 10/100/1000BASE-T-RJ-45 copper ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module · Category 5 twisted pair cable |
LSUM1TGS48SH0 |
48 |
48 × 10GBASE-R-SFP+ fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module |
LSUM2TGS48SH0 |
48 |
48 × 10GBASE-R-SFP+ fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module |
LSUM1TGS48RSH0 |
48 |
48 × 10GBASE-R-SFP+ fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · GE SFP transceiver module |
LSUM1TGS48XSG0 |
48 |
48 × 10GBASE-R-SFP+ fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSUM2TGS48SG0 |
48 |
48 × 10GBASE-R-SFP+ fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSUM1GP40TS8FD0 |
48 |
· 8 × 10GBASE-R-SFP+ fiber ports · 40 × 1000BASE-X-SFP fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSUM2GP40TS8FD0 |
48 |
· 8 × 10GBASE-R-SFP+ fiber ports · 40 × 1000BASE-X-SFP fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSUM2GP44TSSE0 |
48 |
· 4 × 10GBASE-R SFP+/LC fiber ports · 44 × 1000BASE-X-SFP/LC fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSUM2GP24TSSE0 |
28 |
· 4 × 10GBASE-R SFP+/LC fiber ports · 24 × 1000BASE-X-SFP/LC fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSUM2GP24TSSA0 |
28 |
· 4 × 10GBASE-R/ SFP+/LC fiber ports · 24 × 1000BASE-X-SFP/LC fiber ports |
· 10-GE SFP+ transceiver module · FE/GE SFP transceiver module |
LSUM1TGS24FD0 |
24 |
24 × 10GBASE-R-SFP+ fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSUM1TGS16FD0 |
16 |
16 × 10GBASE-R-SFP+ fiber ports |
· 10-GE SFP+ transceiver module · 10-GE SFP+ DAC cable · FE/GE SFP transceiver module |
LSUM1TGS24EC0 |
24 |
24 × 10GBASE-R-SFP+ fiber ports |
· 10-GE SFP+ transceiver module · FE/GE SFP transceiver module |
LSUM1GP48FD0 |
48 |
48 × 1000BASE-X-SFP fiber ports |
FE/GE SFP transceiver module |
LSUM2GP48SA0 |
48 |
48 × 1000BASE-X-SFP/LC fiber ports |
FE/GE SFP transceiver module |
LSUM1TGT24FD0 |
24 |
10GBASE-T-RJ-45 copper port |
Category 6A/7 twisted pair cable |
LSUM1GT48FD0 |
48 |
48 × 10/100/1000BASE-T-RJ-45 copper ports |
Category 5 twisted pair cable |
LSUM2GT48SE0 |
48 |
48 × 10/100/1000BASE-T-RJ-45 copper ports |
Category 5 twisted pair cable |
LSUM2GT48SA0 |
48 |
48 × 10/100/1000BASE-T-RJ-45 copper ports |
Category 5 twisted pair cable |
OAA modules
Table 7-3 OAA module specifications
Model |
Description |
Ports |
Compatible transceiver modules |
LSUM1WCMX20RT |
Access controller module |
· 1 × console port · 1 × 100/1000BASE-T out-of-band management Ethernet port |
Category 5 twisted pair cable |
LSUM1WCMX40RT |
Access controller module |
· 1 × console port · 1 × 100/1000BASE-T out-of-band management Ethernet port |
Category 5 twisted pair cable |
LSUM1FWDEC0 |
Firewall module |
· 1 × console port · 1 × USB port (reserved) · 1 × GE copper port · 1 × hard disk slot |
Category 5 twisted pair cable |
LSUM1NSDEC0 |
NetStream module |
· 1 × console port · 1 × USB port (reserved) · 1 × GE copper port · 1 × hard disk slot |
Category 5 twisted pair cable |
LSUM1ACGDEC0 |
Application control gateway module |
· 1 × console port · 1 × USB port (reserved) · 1 × 10/100/1000BASE-T copper port · 1 × hard disk slot |
Category 5 twisted pair cable |
LSUM1EPSB0 |
EPS endpoint security module |
· 3 × USB 2.0 ports (used only by technical personnel for debugging) · 1 × VGA connector · 1 × 10/100/1000BASE-T management Ethernet port · 1 × console port (used only by technical personnel for debugging) |
Category 5 twisted-pair cable |
LSUM1SDNB0 |
SDN automation module |
· 3 × USB 2.0 ports (used only by technical personnel for debugging) · 1 × VGA connector · 1 × 10/100/1000BASE-T management Ethernet port · 1 × console port (used only by technical personnel for debugging) |
Category 5 twisted-pair cable |
LSUM1WBCZ720XRT |
Multiservice access controller module |
· 3 × USB 2.0 ports (only for debugging use) · 1 × VGA connector · 1 × 1000BASE-T management Ethernet port · 1 × console port |
Category 5 twisted-pair cable |
Switching fabric modules
CAUTION: · The console port on a switching fabric module is only for maintenance by H3C Support. Do not use the port if you have not been trained for that. · You must install switching fabric modules of the same model on the switch. |
IMPORTANT: Follow these restrictions and guidelines when you install switching fabric modules: · On an S10506X switch, populate switching fabric module slots 9 and 10 prior to slot 7. Populate slot 7 only when the switch requires three switching fabric modules. · On an S10508X or S10508X-V switch, populate switching fabric module slots 10 and 12 prior to other switching fabric module slots. Populate slot 11 only when the switch requires five switching fabric modules. · On an S10510X switch, populate switching fabric module slots 13 and 14 prior to slot 11. Populate slot 11 only when the switch requires three switching fabric modules. · Do not install both an LSUM1FAB10XE0 switching fabric module and an LSUM1MPUS10XEB0 MPU on an S10510X switch. · On an S10516X switch, populate switching fabric module slots 18 and 20 prior to other switching fabric module slots. Populate slot 19 only when the switch requires five switching fabric modules. |
Table 7-4 Compatibility between switching fabric modules and switch models
Switch model |
Compatible switching fabric modules |
Quantity |
S10506X |
· LSUM1FAB06XEC0 · LSUM1FAB06XEB0 |
0 to 3 |
S10508X |
· LSUM1FAB08XE0 · LSUM1FAB08XEB0 |
2 to 5 |
S10508X-V |
· LSUM1FAB08XE0 · LSUM1FAB08XEB0 |
2 to 5 |
S10510X |
· LSUM1FAB10XE0 · LSUM1FAB10XEA0 |
0 to 3 |
S10516X |
LSUM1FAB16XD0 |
2 to 5 |
All the switching fabric modules in Table 7-4 except the LSUM1FAB16XD0 each provide an RJ-45 console port.
Power system
Power modules
CAUTION: Do not install power modules of different models on the same switch. |
The LSUM1AC1200 and LSUM2AC2500 AC power modules and the LSUM1DC2400 DC power module are available for the switch.
Table 7-5 Power module specifications
Item |
LSUM1AC1200 |
LSUM1AC2500 |
LSUM1DC2400 |
Rated input voltage range |
100 VAC to 240 VAC @ 50/60 Hz |
100 VAC to 240 VAC @ 50/60 Hz |
–48 VDC to –60 VDC |
Rated output voltage |
12 VDC |
12 VDC |
12 VDC |
Maximum input current |
16 A |
16 A |
60 A |
Maximum output current |
100 A |
· 208 A (220 VAC) · 100 A (110 VAC) |
200 A |
Maximum output power |
1200 W |
· 1200 W (110 VAC) · 2500 W (220 VAC) |
2400 W |
Temperature requirements |
· Operating temperature: –10°C to +50°C (14°F to 122°F) · Storage temperature: –40°C to +70°C (–40°F to +185°F) |
· Operating temperature: –10°C to +50°C (14°F to 122°F) · Storage temperature: –40°C to +70°C (–40°F to +185°F) |
· Operating temperature: –10°C to +50°C (14°F to 122°F) · Storage temperature: –40°C to +70°C (–40°F to +185°F) |
Applicable switch models |
· S10506X · S10508X · S10508X-V · S10510X |
All S10500X models |
All S10500X models |
Quantity |
· S10506X: 1 to 4 · S10508X/S10508X-V/S10510X: 1 to 6 |
· S10506X: 1 to 4 · S10508X/S10508X-V/S10510X: 1 to 6 · S10516X: 1 to 16 |
· S10506X: 1 to 4 · S10508X/S10508X-V/S10510X: 1 to 6 · S10516X: 1 to 16 |
Make sure the total maximum output power of the ordered power modules is greater than the system power consumption. As a best practice, reserve 20% of the maximum output power.
|
NOTE: When the temperature of a power module exceeds the acceptable temperature range, the power module is automatically powered off. When the temperature returns to the acceptable temperature range, the power module is automatically powered on. |
Power cords
DC power cords
DC power cords are used for connecting DC power modules of the switch to the external DC power source.
Table 7-6 DC power cords available for S10500X switches
Chassis model |
DC power cord quantity |
Cord code and length |
Remarks |
S10506X |
1 to 4 pairs |
· 0404A0E1, 3 m (9.84 ft) · 0404A0E2, 15 m (49.21 ft) |
|
S10508X |
1 to 6 pairs |
· 0404A0E1, 3 m (9.84 ft) · 0404A0E2, 15 m (49.21 ft) |
Used for connecting the LSUM1DC2400 power module to a DC power source |
S10508X-V |
1 to 6 pairs |
· 0404A0E1, 3 m (9.84 ft) · 0404A0E2, 15 m (49.21 ft) |
|
S10510X |
1 to 6 pairs |
· 0404A0E1, 3 m (9.84 ft) · 0404A0E2, 15 m (49.21 ft) |
|
S10508X-V |
1 to 16 pairs |
· 0404A0E1, 3 m (9.84 ft) · 0404A0E2, 15 m (49.21 ft) |
AC power cords
An AC power cord is used to connect an AC power module of the switch to the external AC power supply system.
To select an AC power cord for an AC power module, consider the following items:
· Power capacity of the power module.
· Current-carrying capacity of the power cord.
· Region-and country-specific plug type.
The AC power modules available for the switch require a 16A AC power cord. Table 7-7 describes the region-and country-specific plug types for 16A AC power cords.
Table 7-7 16A AC power cords used in different countries or regions
1 |
Plug type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||
I type |
04043396 (3 m, or 9.8 ft) |
Mainland China |
N/A |
N/A |
|||
Plug outline |
Power cord outline |
Connector outline |
|||||
2 |
Plug type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||
C20 type |
0404A0C2 (3 m, or 9.8 ft) |
Mainland China |
N/A |
N/A |
|||
Plug outline |
Power cord outline |
Connector outline |
|||||
3 |
Plug type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||
B type |
0404A063 (3 m, or 9.8 ft) |
Canada and U.S.A |
Mexico, Argentina, Brazil, Columbia, Venezuela, Thailand, Peru, Philippine, and A6 countries or regions |
N/A |
|||
Plug outline |
Power cord outline |
Connector outline |
|||||
4 |
Plug type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||
F type |
0404A061 (3 m, or 9.8 ft) |
Holland, Denmark, Sweden, Finland, Norway, Germany, France, Austria, Belgium, and Italy |
Indonesia, Turkey, Russia, and CIS |
N/A |
|||
Plug outline |
Power cord outline |
Connector outline |
|||||
5 |
Plug type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||
B type |
0404A062 (3 m, or 9.8 ft) |
Japan |
N/A |
N/A |
|||
Plug outline |
Power cord outline |
Connector outline |
|||||
6 |
Plug type |
Code (Length) |
Countries or regions where the type of power cords conforms to local safety regulations and can be used legally |
Other countries or regions using this type of power cords |
Countries or regions seldom using this type of power cords |
||
I type |
0404A01A (3 m, or 9.8 ft) |
Australia |
N/A |
N/A |
|||
Plug outline |
Power cord outline |
Connector outline |
|||||
|
NOTE: The connector outline figures shown in the table are C19 straight connectors. |
Fan trays
The S10506X, S10508X, S10508X-V, and S10510X switches come with a fan tray installed in the FAN0 slot. You can install a fan tray in the FAN1 slot as required. The S10516X switch comes with a fan tray installed in each fan tray slot.
If a fan tray fails, purchase a fan tray compatible with the switch to replace the failed one.
Table 7-8 Fan tray specifications
Fan tray |
Number of fans |
Fan diameter |
Maximum air flow rate |
S10506X master fan tray |
6 |
120 mm (4.72 in) |
680 CFM |
S10506X standby fan tray |
2 |
120 mm (4.72 in) |
200 CFM |
S10508X master fan tray |
8 |
120 mm (4.72 in) |
920 CFM |
S10508X standby fan tray |
2 |
120 mm (4.72 in) |
200 CFM |
S10508X-V fan tray |
12 |
120 mm (4.72 in) |
840 CFM |
S10510X master fan tray |
10 |
120 mm (4.72 in) |
980 CFM |
S10510X standby fan tray |
2 |
120 mm (4.72 in) |
260 CFM |
S10516X fan tray |
2 |
80 mm (3.15 in) |
350 CFM |