- Table of Contents
-
- 01-Fundamentals Command Reference
- 00-Preface
- 01-CLI commands
- 02-RBAC commands
- 03-Login management commands
- 04-FTP and TFTP commands
- 05-File system management commands
- 06-Configuration file management commands
- 07-Multichassis configuration sync commands
- 08-Software upgrade commands
- 09-ISSU commands
- 10-GIR commands
- 11-Automatic configuration commands
- 12-Target configuration management commands
- 13-Device management commands
- 14-Tcl commands
- 15-Python commands
- 16-License management commands
- Related Documents
-
Title | Size | Download |
---|---|---|
09-ISSU commands | 319.09 KB |
ISSU commands
ISSU is available only for dual-chassis IRF fabrics. When the master reboots for an upgrade, the subordinate member takes over for service continuity.
MDC is supported only when the device operates in standalone mode. For more information about standalone mode, see IRF configuration in Virtual Technologies Configuration Guide. For more information about MDC and device models that support MDC, see MDC configuration in Virtual Technologies Configuration Guide.
display install active
Use display install active to display active software images.
In standalone mode:
display install active [ slot slot-number ] [ verbose ]
In IRF mode:
display install active [ chassis chassis-number slot slot-number ] [ verbose ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays information for all cards. (In standalone mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The chassis-number argument represents the member ID of the IRF member device. The slot-number argument represents the slot number of the card. If you do not specify a card, this command displays information for all cards. (In IRF mode.)
verbose: Displays detailed information. If you do not specify this keyword, the command displays only image names.
Examples
# (In standalone mode.) Display active software images.
<Sysname> display install active
Active packages on slot 1:
flash:/boot.bin
flash:/system.bin
flash:/feature1.bin
# (In IRF mode.) Display active software images.
<Sysname> display install active
Active packages on chassis 1 slot 1:
flash:/boot.bin
flash:/system.bin
flash:/patch1.bin
# (In standalone mode.) Display detailed information about active software images.
<Sysname> display install active verbose
Active packages on slot 1:
flash:/boot.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: boot
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu
[Component]
Component: boot
Description: boot package
flash:/system.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: system
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu
[Component]
Component: system
Description: system package
flash:/feature1.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: test
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu
[Component]
Component: test
Description: test package
# (In IRF mode.) Display detailed information about active software images.
<Sysname> display install active verbose
Active packages on chassis 1 slot 1:
flash:/boot.bin
[Package]
Vendor: H3C
Product:S7500XG
Service name: boot
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: boot
Description: boot package
flash:/system.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: system
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: system
Description: system package
flash:/patch1.bin
[Package]
Vendor: H3C
Product:S7500XG
Service name: test
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: test
Description: test package
Field |
Description |
[Package] |
Detailed information about the software image. |
Service name |
Image type: · boot—Boot image. · system—System image. · boot patch—Patch image for the boot image. · system patch—Patch image for the system image. · Any other value indicates a feature image. |
Supported board |
Hardware types supported by the software image: · mpu—MPU. · lpu—Service card. |
[Component] |
Information about components included in the image file. |
Related commands
install active
display install backup
Use display install backup to display backup startup software images.
Syntax
In standalone mode:
display install backup [ slot slot-number ] [ verbose ]
In IRF mode:
display install backup [ chassis chassis-number slot slot-number ] [ verbose ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays information for all cards. (In standalone mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The chassis-number argument represents the member ID of the IRF member device. The slot-number argument represents the slot number of the card. If you do not specify a card, this command displays information for all cards. (In IRF mode.)
verbose: Displays detailed information. If you do not specify this keyword, the command displays only image names.
Usage guidelines
Application scenarios
When the main boot or system image is missing or corrupt, the device uses the backup startup images to start the device. You can use this command to display backup startup software images. For more information, see Fundamentals Configuration Guide.
Restrictions and guidelines
To modify the backup startup image list, use the boot-loader file command.
Examples
# (In standalone mode.) Display the backup startup software images.
<Sysname> display install backup
Backup startup software images on slot 1:
flash:/boot.bin
flash:/system.bin
# (In IRF mode.) Display the backup startup software images.
<Sysname> display install backup
Backup startup software images on chassis 1 slot 1:
flash:/boot.bin
flash:/system.bin
# (In standalone mode.) Display detailed information about backup startup software images.
<Sysname> display install backup verbose
Backup startup software images on slot 1:
flash:/boot.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: boot
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu
[Component]
Component: boot
Description: boot package
flash:/system.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: system
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu
[Component]
Component: system
Description: system package
# (In IRF mode.) Display detailed information about backup startup software images.
<Sysname> display install backup verbose
Backup startup software images on chassis 1 slot 1:
flash:/boot.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: boot
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: boot
Description: boot package
flash:/system.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: system
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: system
Description: system package
Backup startup software images on chassis 2 slot 1:
flash:/boot.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: boot
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: boot
Description: boot package
flash:/system.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: system
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: system
Description: system package
For information about the command output, see Table 1.
Related commands
boot-loader file
display install committed
display install committed
Use display install committed to display main startup software images.
Syntax
In standalone mode:
display install committed [ slot slot-number ] [ verbose ]
In IRF mode:
display install committed [ chassis chassis-number slot slot-number ] [ verbose ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays information for all cards. (In standalone mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The chassis-number argument represents the member ID of the IRF member device. The slot-number argument represents the slot number of the card. If you do not specify a card, this command displays information for all cards. (In IRF mode.)
verbose: Displays detailed information. If you do not specify this keyword, the command displays only image names.
Usage guidelines
Application scenarios
Some install commands modify the current software image list but do not modify the main startup image list. For the software image changes to take effect after a reboot, you must execute the install commit command to update the main startup image list with the image changes. You can use the display install committed command to verify the operation results.
Restrictions and guidelines
Both the install commit and boot-loader file commands modify the main startup software image list.
Examples
# (In standalone mode.) Display the main startup software images.
<Sysname> display install committed
Committed packages on slot 1:
flash:/boot.bin
flash:/system.bin
flash:/feature1.bin
# (In IRF mode.) Display the main startup software images.
<Sysname> display install committed
Committed packages on chassis 1 slot 1:
flash:/boot.bin
flash:/system.bin
flash:/patch1.bin
# (In standalone mode.) Display detailed information about main startup software images.
<Sysname> display install committed verbose
Committed packages on slot 1:
flash:/boot.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: boot
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu
[Component]
Component: boot
Description: boot package
flash:/system.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: system
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu
[Component]
Component: system
Description: system package
flash:/feature1.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: feature1
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu
[Component]
Component: feature1
Description: feature1 package
# (In IRF mode.) Display detailed information about main startup software images.
<Sysname> display install committed verbose
Committed packages on chassis 1 slot 1:
flash:/boot.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: boot
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: boot
Description: boot package
flash:/system.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: system
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: system
Description: system package
flash:/patch1.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: patch1
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: patch1
Description: patch1 package
Committed packages on chassis 2 slot 1:
flash:/boot.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: boot
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: boot
Description: boot package
flash:/system.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: system
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: system
Description: system package
flash:/patch1.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: patch1
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: patch1
Description: patch1 package
For information about the command output, see Table 1.
Related commands
boot-loader file
display install backup
install commit
display install inactive
Use display install inactive to display inactive software images in the root directories of file systems.
Syntax
In standalone mode:
display install inactive [ slot slot-number ] [ verbose ]
In IRF mode:
display install inactive [ chassis chassis-number slot slot-number ] [ verbose ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays information for all cards. (In standalone mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The chassis-number argument represents the member ID of the IRF member device. The slot-number argument represents the slot number of the card. If you do not specify a card, this command displays information for all cards. (In IRF mode.)
verbose: Displays detailed information. If you do not specify this keyword, the command displays only image names.
Examples
# (In standalone mode.) Display brief information about inactive software images in the root directories of the file systems.
<Sysname> display install inactive
Inactive packages on slot 1:
flash:/feature1.bin
# (In IRF mode.) Display brief information about inactive software images in the root directories of the file systems.
<Sysname> display install inactive
Inactive packages on chassis 1 slot 1:
flash:/patch1.bin
Inactive packages on chassis 2 slot 1:
flash:/patch1.bin
# (In standalone mode.) Display detailed information about inactive software images in the root directories of the file systems.
<Sysname> display install inactive verbose
Inactive packages on slot 1:
flash:/feature1.bin
[Package]
Vendor: H3C
Product:S7500XG
Service name: feature1
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu
[Component]
Component: feature1
Description: feature1 package
# (In IRF mode.) Display detailed information about inactive software images in the root directories of the file systems.
<Sysname> display install inactive verbose
Inactive packages on chassis 1 slot 1:
flash:/patch1.bin
[Package]
Vendor: H3C
Product:S7500XG
Service name: patch1
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: patch1
Description: patch1 package
Inactive packages on chassis 2 slot 1:
flash:/patch1.bin
[Package]
Vendor: H3C
Product:S7500XG
Service name: patch1
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
[Component]
Component: patch1
Description: patch1 package
For information about the command output, see Table 1.
Related commands
install deactivate
display install ipe-info
Use display install ipe-info to display the software images included in an .ipe file.
Syntax
display install ipe-info ipe-filename
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
ipe-filename: Specifies an .ipe file in the filesystemname/filename.ipe format. The file must be stored in the root directory of a file system on the device. The value string excluding the file system location section (if any) can have a maximum of 63 characters. For more information about specifying a file, see file system management in Fundamentals Configuration Guide.
Examples
# (In standalone mode.) Display information about .ipe file flash:/test.ipe.
<Sysname> display install ipe-info flash:/test.ipe
Verifying the file flash:/test.ipe on slot 1................Done.
H3C S7503X-G images in IPE:
boot.bin
system.bin
# (In IRF mode.) Display information about .ipe file flash:/test.ipe.
<Sysname> display install ipe-info flash:/test.ipe
Verifying the file flash:/test.ipe on chassis 1 slot 1................Done.
H3C S7503X-G images in IPE:
boot.bin
system.bin
Related commands
display install package
display install job
Use display install job to display ongoing ISSU activate, deactivate, and rollback operations.
Syntax
display install job
Views
Any view
Predefined user roles
network-admin
network-operator
Examples
# (In standalone mode.) Display ongoing ISSU activate, deactivate, and rollback operations.
<Sysname> display install job
JobID:5
Action:install activate flash:/feature1.bin on slot 1
The output shows that the device is executing the install activate flash:/feature1.bin slot 1 command.
# (In IRF mode.) Display ongoing ISSU activate, deactivate, and rollback operations.
JobID:5
Action:install activate flash:/patch1.bin on chassis 1 slot 1
The output shows that the device is executing the install activate flash:/patch1.bin chassis 1 slot 1 command.
display install log
Use display install log to display ISSU log information.
Syntax
display install log [ log-id ] [ verbose ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
log-id: Specifies a log entry by its ID. If you do not specify this argument, the command displays all ISSU log entries.
verbose: Displays detailed ISSU log information. If you do not specify this keyword, the command displays brief ISSU log information.
Usage guidelines
Operating mechanism
The device creates one log entry for each ISSU operation to track the ISSU process and operation result.
Restrictions and guidelines
The ISSU log can contain a maximum of 50 entries. The latest entry overwrites the oldest entry if the log is full.
A device reboot clears all ISSU log entries.
Examples
# (In standalone mode.) Display all ISSU log entries.
<Sysname> display install log
Install job 1 started by user root at 04/28/2001 08:39:29.
Job 1 completed successfully at 04/28/2001 08:39:30.
Install job 1 started by user root at 04/28/2001 08:39:29.
Install activate flash:/feature1.bin on slot 1
Job 1 completed successfully at 04/28/2001 08:39:30.
Install job 1 started by user root at 04/28/2001 08:39:29.
Job 1 completed successfully at 04/28/2001 08:39:30.
-----------------------------------------------------------
Install job 2 started by user root at 04/28/2001 08:40:29.
Job 2 completed successfully at 04/28/2001 08:40:30.
Install job 2 started by user root at 04/28/2001 08:40:29.
Install activate flash:/route.bin on slot 1
Job 2 completed successfully at 04/28/2001 08:40:30.
Install job 2 started by user root at 04/28/2001 08:40:29.
Job 2 completed successfully at 04/28/2001 08:40:30.
# (In IRF mode.) Displays detailed information about all ISSU log entries.
<Sysname> display install log
Install job 1 started by user root at 04/28/2001 08:39:29.
Job 1 completed successfully at 04/28/2001 08:39:30.
Install job 1 started by user root at 04/28/2001 08:39:29.
Install activate flash:/patch1.bin on chassis 1 slot 1
Job 1 completed successfully at 04/28/2001 08:39:30.
Install job 1 started by user root at 04/28/2001 08:39:29.
Job 1 completed successfully at 04/28/2001 08:39:30.
-----------------------------------------------------------
Install job 2 started by user root at 04/28/2001 08:40:29.
Job 2 completed successfully at 04/28/2001 08:40:30.
Install job 2 started by user root at 04/28/2001 08:40:29.
Install activate flash:/route.bin on chassis 1 slot 1
Job 2 completed successfully at 04/28/2001 08:40:30.
Install job 2 started by user root at 04/28/2001 08:40:29.
Job 2 completed successfully at 04/28/2001 08:40:30.
# (In standalone mode.) Displays detailed information about ISSU log entry 1.
<Sysname> display install log 1 verbose
Install job 1 started by user root at 04/28/2001 08:39:29.
Job 1 completed successfully at 04/28/2001 08:39:30.
Install job 1 started by user root at 04/28/2001 08:39:29.
Install activate flash:/feature1.bin on slot 1
Job 1 completed successfully at 04/28/2001 08:39:30.
Install job 1 started by user root at 04/28/2001 08:39:29.
Job 1 completed successfully at 04/28/2001 08:39:30.
Detail of activating packages on slot 1.
Get upgrade policy successfully.
Detail of activating packages on slot 1.
Uncompress package to system successfully.
Remove files from system successfully.
# (In IRF mode.) Displays detailed information about ISSU log entry 1.
<Sysname> display install log 1 verbose
Install job 1 started by user root at 04/28/2001 08:39:29.
Job 1 completed successfully at 04/28/2001 08:39:30.
Install job 1 started by user root at 04/28/2001 08:39:29.
Install activate flash:/patch1.bin on chassis 1 slot 1
Job 1 completed successfully at 04/28/2001 08:39:30.
Install job 1 started by user root at 04/28/2001 08:39:29.
Job 1 completed successfully at 04/28/2001 08:39:30.
Detail of activating packages on chassis 1 slot 1.
Get upgrade policy successfully.
Detail of activating packages on chassis 1 slot 1.
Uncompress package to system successfully.
Remove files from system successfully.
Table 2 Command output
Field |
Description |
Detail of xxx |
Detailed information about an ISSU operation. |
Get upgrade policy successfully. |
Obtained the upgrade policy. |
Uncompress package to system successfully. |
Decompressed the package successfully. |
Remove files from system successfully. |
Deleted files from the system successfully. |
Related commands
reset install log-history oldest
display install package
Use display install package to display software image file information.
Syntax
display install package { filename | all } [ verbose ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
filename: Specifies a .bin file in the filesystemname/filename.bin format. The file must be stored in the root directory of a file system on the device. The value string excluding the file system location section (if any) can have a maximum of 63 characters. For more information about specifying a file, see file system management in Fundamentals Configuration Guide.
all: Specifies all software image files in the root directories of the active MPU's file systems. (In standalone mode.)
all: Specifies all software image files in the root directories of the file systems on the global active MPU. (In IRF mode.)
verbose: Displays detailed information. If you do not specify this keyword, the command displays only basic software image information.
Examples
# Display information about system.bin.
<Sysname> display install package flash:/system.bin
flash:/system.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: system
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu
# Display detailed information about system.bin.
<Sysname> display install package flash:/system.bin verbose
flash:/system.bin
[Package]
Vendor: H3C
Product: S7500XG
Service name: system
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu
[Component]
Component: system
Description: system package
For information about the command output, see Table 1.
display install rollback
Use display install rollback to display rollback point information.
Syntax
display install rollback [ point-id ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
point-id: Specifies a rollback point ID. If you do not specify a rollback point ID, the command displays all rollback points.
Usage guidelines
Application scenarios
Use this command to identify available rollback points during an ISSU that uses install commands.
Restrictions and guidelines
The system does not record rollback points during an ISSU that uses issu commands.
Examples
# (In standalone mode.) Display all rollback points.
<Sysname> display install rollback
Install rollback information 1 on slot 1:
Updating from flash:/route-1.bin
to flash:/route-2.bin.
Install rollback information 2 on slot 1:
Deactivating flash:/route-2.bin
# (In IRF mode.) Display all rollback points.
<Sysname> display install rollback
Install rollback information 1 on chassis 1 slot 1
Updating from flash:/route-1.bin
to flash:/route-2.bin.
Install rollback information 2 on chassis 1 slot 1
Deactivating flash:/route-2.bin
The output shows that the device has two rollback points.
· At rollback point 1, flash:/route-1.bin was upgraded to flash:/route-2.bin.
· At rollback point 2, flash:/route-2.bin was deactivated.
Related commands
install rollback
reset install rollback oldest
display install which
Use display install which to display all software image files that include a specific component or file.
Syntax
In standalone mode:
display install which { component name | file filename } [ slot slot-number ]
In IRF mode:
display install which { component name | file filename } [ chassis chassis-number slot slot-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
component name: Specifies a component name.
file filename: Specifies a file in the filename.extension format, a case-insensitive string of up to 63 characters. It cannot contain path information.
slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command displays information for all cards. (In standalone mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The chassis-number argument represents the member ID of the IRF member device. The slot-number argument represents the slot number of the card. If you do not specify a card, this command displays information for all cards. (In IRF mode.)
Usage guidelines
Application scenarios
When the system displays a component or file error, use this command to identify the image files that include the component or file. Then, you can use the install verify command to identify image file problems.
Operating mechanism
A component is a collection of features. The features of a component are installed or uninstalled at the same time. This command searches only the root directories of the file systems at the specified location.
Examples
# (In standalone mode.) Display the software image file that includes pkg_ctr.
<Sysname> display install which file pkg_ctr
Verifying the file flash:/system-t0001015.bin on slot 1..........................Done.
Found pkg_ctr in flash:/system-t0001015.bin on slot 1.
flash:/system-t0001015.bin
[Package]
Vendor: H3C
Product:S7500XG
Service name: system
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu
Verifying the file flash:/boot-d2601007.bin on slot 1.....Done.
# (In IRF mode.) Display the software image file that includes pkg_ctr.
<Sysname> display install which file pkg_ctr
Verifying the file flash:/system-t0001015.bin on chassis 1 slot 1...........Done.
Found pkg_ctr in flash:/system-t0001015.bin on chassis 1 slot 1.
flash:/system-t0001015.bin
[Package]
Vendor: H3C
Product:S7500XG
Service name: system
Platform version: 7.1.070
Product version: Test 0001015
Supported board: mpu lpu
Verifying the file flash:/boot-d2601007.bin on slot 1.....Done.
Table 3 Command output
Field |
Description |
Verifying the file |
The system was verifying the validity of the file. |
[Package] |
Detailed information about the software image. |
Service name |
Image type: · boot—Boot image. · system—System image. · patch—Patch image. · Any other value indicates a feature image. |
Supported board |
Hardware types supported by the software image: · mpu—MPU. · lpu—Service card. |
display issu rollback-timer
Use display issu rollback-timer to display automatic rollback timer information.
Syntax
display issu rollback-timer
Views
Any view
Predefined user roles
network-admin
network-operator
Usage guidelines
Change to the automatic rollback interval does not take effect on the ongoing ISSU process. The current remaining rollback time might be greater than the specified automatic rollback interval.
Examples
# Display automatic rollback timer information after the issu run switchover command is executed.
<Sysname> display issu rollback-timer
Rollback timer: Working
Rollback interval: 45 minutes
Rollback time remaining : 40 minutes
# Display automatic rollback timer information after the issu accept command is executed.
<Sysname> display issu rollback-timer
Rollback timer: Not working
Rollback interval: 30 minutes
# Display automatic rollback timer information when no ISSU process is taking place.
<Sysname> display issu rollback-timer
Rollback timer: Not working
Rollback interval: 45 minutes
Related commands
issu rollback-timer
display issu state
Use display issu state to display ISSU status information.
Syntax
display issu state
Views
Any view
Predefined user roles
network-admin
network-operator
Usage guidelines
Application scenarios
During an ISSU that uses issu commands, you can use this command to verify the ISSU status and determine what to do next.
Restrictions and guidelines
This command does not apply to an ISSU that uses install commands, because the ISSU state machine is not involved.
Examples
# (In IRF mode.) On a multichassis IRF fabric, display ISSU status information on the original master after the issu load command is completed.
ISSU state: Loaded
Compatibility: Incompatible
Work state: Independent active
Upgrade method: Chassis by chassis
Upgraded chassis:
chassis 2
Current upgrading chassis: None
Previous version list:
boot: 7.1.070, Test 0001015
system: 7.1.070, Test 0001015
patch1: 7.1.070, Test 0001015
Previous software images:
flash:/boot-t0001015.bin
flash:/system-t0001015.bin
flash:/patch1-t0001015.bin
Upgrade version list:
boot: 7.1.070, Test 0001016
system: 7.1.070, Test 0001016
patch1: 7.1.070, Test 0001016
Upgrade software images:
flash:/boot-t0001016.bin
flash:/system-t0001016.bin
flash:/patch1-t0001016.bin
Table 4 Command output
Field |
Description |
ISSU state |
ISSU status: · Init—The ISSU process has not started or has finished. · Loading—The system is executing the issu load command. · Loaded—The issu load command is completed. · Switching—The system is executing the issu run switchover command. · Switchover—The issu run switchover command is completed. · Accepted—The issu accept command is completed. · Committing—The system is executing the issu commit command. · Rollbacking—A rollback is in progress. · Unknown—An upgrade is in progress. This value might appear when you execute the command on an original standby MPU. |
Compatibility |
Version compatibility: · Compatible—Upgrade to a compatible version. · Incompatible—Upgrade to an incompatible version. · Unknown—No upgrade is in progress. |
Work state |
Operating status of the device: · Normal—The device is operating correctly. · Independent active—When you perform an ISSU to an incompatible version, the standby MPU that is upgraded first enters this state. In this state, the two MPUs of the device are running different software versions. |
Upgrade method |
Upgrade mode: · Card by card—MPUs are upgraded one by one. · Chassis by chassis ¡ For a compatible upgrade of a multichassis IRF fabric, one or more subordinate members are upgraded first, and then the original master and the remaining subordinate members are upgraded. ¡ For an incompatible upgrade of a multichassis IRF fabric, one subordinate member is upgraded first, and then the original master and the remaining subordinate members. |
Current version list |
Versions of currently running images. This field is displayed if no upgrade is taking place. |
Current software images |
File names of currently running images. This field is displayed if no upgrade is taking place. |
Previous version list |
Versions of the images that were running on the device before the ISSU. If you execute this command on an original standby MPU during an ISSU to an incompatible version, this field displays Unknown. |
Previous software images |
File names of the images that were running on the device before the ISSU. If you execute this command on an original standby MPU during an ISSU to an incompatible version, this field displays Unknown. |
Upgrade version list |
Versions of the upgrade images. If you execute this command on an original standby MPU during an ISSU to an incompatible version, this field displays Unknown. |
Upgrade software images |
File names of the upgrade images. If you execute this command on an original standby MPU during an ISSU for an incompatible version, this field displays Unknown. |
Related commands
issu accept
issu commit
issu load
issu rollback
display version comp-matrix file
Use display version comp-matrix file to display the recommended ISSU methods.
Syntax
display version comp-matrix file { boot filename | system filename | feature filename&<1-30> | patch filename&<1-30> } *
display version comp-matrix file ipe ipe-filename [ patch filename&<1-30> ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
boot: Specifies a boot image file.
system: Specifies a system image file.
feature: Specifies a space-separated list of up to 30 feature image files.
patch: Specifies a space-separated list of up to 30 patch image files.
filename: Specifies a .bin file in the filesystemname/filename.bin format. The file must be stored in the root directory of a file system on the device. The value string excluding the file system location section (if any) can have a maximum of 63 characters. For more information about specifying a file, see file system management in Fundamentals Configuration Guide.
ipe-filename: Specifies an .ipe file in the filesystemname/filename.ipe format. The file must be stored in the root directory of a file system on the device. The value string excluding the file system location section (if any) can have a maximum of 63 characters. For more information about specifying a file, see file system management in Fundamentals Configuration Guide.
If one or more images are incompatible, the incompatible upgrade method applies. The entire system needs to be rebooted during an incompatible upgrade.
Examples
# (In standalone mode.) Display the recommended ISSU methods. In this example, the specified image is compatible with the running images.
<Sysname> display version comp-matrix file feature flash:/feature1-t0001015.bin patch flash:/feature-patch1-t0001015.bin
Verifying the file flash:/feature1-t0001015.bin on slot 0.....Done.
Verifying the file flash:/feature-patch1-t0001015.bin on slot 0.....Done.
Slot Upgrade Way
0 Service Upgrade
1 Service Upgrade
2 Service Upgrade
Influenced service according to following table on slot 0:
flash:/feature1-t0001015.bin
Feature1
Influenced service according to following table on slot 2:
flash:/feature1-t0001015.bin
Feature1
Influenced service according to following table on slot 1:
flash:/feature1-t0001015.bin
Feature1
Field |
Description |
Verifying the file |
The system was verifying the validity of the file. |
Influenced service according to following table |
Services that will be affected by the upgrade. This field is displayed only for compatible versions. |
Incompatible upgrade |
You are upgrading the software to an incompatible version. |
Upgrade Way |
ISSU method: · File Upgrade. · Reboot. This field is displayed only for compatible versions. For more information about ISSU methods, see Fundamentals Configuration Guide. |
Related commands
issu load
install abort
Use install abort to abort an ongoing activate or deactivate operation.
Syntax
install abort [ job-id ]
Views
User view
Predefined user roles
network-admin
Parameters
job-id: Specifies the job ID of an ISSU operation. If you do not specify this argument, the command aborts all ongoing software image activate and deactivate operations.
Usage guidelines
Operating mechanism
When you abort an ongoing activate or deactivate operation, the system rolls back to the status it was in before the operation was started.
Restrictions and guidelines
The system creates a software image management job each time you use the install activate, install add, install commit, install deactivate, install remove, or install rollback to command. Each job represents one command and is assigned a unique job ID. To obtain the ID of a job, use the display install job command.
Examples
# Abort all ongoing software image activate and deactivate operations.
<Sysname> install abort
Related commands
display install job
install activate
Use install activate to activate software images, or identify the ISSU method and the possible impact on the device.
Syntax
In standalone mode:
install activate { boot filename | system filename | feature filename&<1-30> } * slot slot-number [ test ]
install activate patch filename { all | slot slot-number }
In IRF mode:
install activate { boot filename | system filename | feature filename&<1-30> } * chassis chassis-number slot slot-number [ test ]
install activate patch filename { all | chassis chassis-number slot slot-number }
Views
User view
Predefined user roles
network-admin
Parameters
boot: Specifies a boot image file.
system: Specifies a system image file.
feature: Specifies a space-separated list of up to 30 feature image files
patch: Specifies a patch image file. You can specify only one patch image file for the command at a time. However, you can execute the command multiple times to activate multiple patch image files. You can specify both incremental and non-incremental patch image files. The device can use a maximum of 30 incremental patch image files. Because the boot, system, and feature images each can have one non-incremental patch image file, the device can use a maximum of 16 non-incremental patch image files. For more information about incremental and non-incremental patch images, see software upgrade in Fundamentals Configuration Guide.
filename: Specifies a .bin file in the filesystemname/filename.bin format. The file must be stored in the root directory of a file system on the device. The value string excluding the file system location section (if any) can have a maximum of 63 characters. For more information about specifying a file, see file system management in Fundamentals Configuration Guide.
all: Specifies all cards. (In standalone mode.)
all: Specifies all cards. (In IRF mode.)
slot slot-number: Specifies a card by its slot number. (In standalone mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The chassis-number argument represents the member ID of the IRF member device. The slot-number argument represents the slot number of the card. (In IRF mode.)
test: Only identifies the ISSU method to be used for the upgrade. If you do not specify this keyword, the command activates the specified software images.
Before you use this command to activate a software image, read the release notes to identify the licensing requirements for the image. If the image requires a license, make sure the device has a valid license installed for the image.
At reboot, a subordinate device automatically synchronizes the master device's configuration and status data. You must wait for the synchronization to complete before using the install activate command on the subordinate device. To identify whether the synchronization is complete, use the display system stable state command. The synchronization is complete if the System State field displays Stable.
Restrictions and guidelines
The software images for the device are digitally signed. The system will verify the digital signatures of the specified software images for authenticity and integrity before it activates them. If the digital signature verification fails, the system will not activate the specified images and you will receive a digital signature verification failure message.
If you upgrade images other than patch images, the upgrade can succeed only if the boot, system, and feature images in the startup software image list are the same version after the upgrade.
To ensure a successful upgrade, maintain version consistency across the boot, system, and feature images. If you are upgrading some of the images, make sure the specified upgrade images are the same version as the images not to be upgraded in the startup software image list.
|
NOTE: Be aware that using this command to upgrade the boot, system, or feature image will cause the patch images (if any) to be deleted from the startup software image list. Install the patch images as needed if the upgrade software version has not removed the issues that are resolved by using the patches. |
If this command fails, perform the following tasks:
1. If some features are not needed anymore, disable the features and use the install deactivate command to uninstall the feature images.
2. Obtain the correct version of the images. Make sure all images in the startup software image list will be the same version after the upgrade.
3. Execute this command to activate the images.
Images run in memory immediately after they are activated. However, only patch images activated by using the install activate patch filename all command still run in memory after a reboot. For other images to take effect after a reboot, you must commit the software change by using the install commit command.
If the specified files are not stored on the MPU to be upgraded, the command copies the files to the MPU automatically.
(In standalone mode.) If you specify the active MPU for the slot slot-number option, the command takes effect on the active MPU and all LPUs. If you specify the standby MPU for the slot slot-number option, the command takes effect only on the standby MPU.
(In IRF mode.) If you specify the global active MPU for the chassis chassis-number slot slot-number option, the command takes effect on the global active MPU and all LPUs on the member device. If you specify a standby MPU for the chassis chassis-number slot slot-number option, the command takes effect on the standby MPU.
Examples
# (In standalone mode.) Identify the ISSU method for feature upgrade with feature1.bin on the standby MPU (in slot 1) and the upgrade impact.
<Sysname> install activate feature flash:/feature1.bin slot 1 test
Copying file flash:/feature1.bin to slot1#flash:/feature1.bin......Done.
Verifying the file flash:/feature1.bin on slot 1.....Done.
Upgrade summary according to following table:
flash:/feature1.bin
Running Version New Version
Test 0001015 Test 0001016
Slot Upgrade Way
1 Service Upgrade
Influenced service according to following table:
flash:/feature1.bin
Feature1
The output shows that a service upgrade is recommended. The Feature1 module will be rebooted during the upgrade.
# (In standalone mode.) Activate the system image in system.bin and the feature images in feature1.bin on the standby MPU (in slot 1).
<Sysname> install activate system flash:/system.bin feature flash:/feature1.bin slot 1
Copying file flash:/system.bin to slot1#flash:/system.bin......Done.
Verifying the file flash:/system.bin on slot 1.....Done.
Copying file flash:/feature1.bin to slot1#flash:/feature1.bin......Done.
Verifying the file flash:/feature1.bin on slot 1.....Done.
Verifying the file flash:/feature1.bin on slot 1.....Done.
Verifying the file flash:/system.bin on slot 1.....Done.
Upgrade summary according to following table:
flash:/system.bin
Running Version New Version
Test 0001015 Test 0001016
flash:/feature1.bin
Running Version New Version
None Test 0001015
Slot Upgrade Way
1 Service Upgrade
Upgrading software images to compatible versions. Continue? [Y/N]:y
This operation might take several minutes, please wait...Done.
# (In IRF mode.) Activate the patch image in patch1.bin on the global standby MPU in slot 1 of chassis 1.
<Sysname> install activate patch flash:/patch1.bin chassis 1 slot 1
Copying file flash:/patch1.bin to chassis1#slot1#flash:/patch1.bin......Done.
Verifying the file flash:/patch1.bin on chassis 1 slot 1.....Done.
This operation might take several minutes, please wait...Done.
Table 6 Command output
Field |
Description |
Verifying the file |
The system was verifying the validity of the file. |
Upgrade summary according to following table |
Upgrade summary. |
Running Version |
Version number of the running software. |
New Version |
Version number of the new software. |
Upgrade Way |
ISSU methods: · Service Upgrade. · File Upgrade. · Reboot. This field is displayed only for an upgrade to a compatible version. For more information about ISSU methods, see Fundamentals Configuration Guide. |
Influenced service according to following table |
Services influenced by the upgrade. |
Related commands
display install active
install commit
install deactivate
install add
Use install add to decompress an .ipe file.
Syntax
install add ipe-filename filesystem
Views
User view
Predefined user roles
network-admin
Parameters
ipe-filename: Specifies an .ipe file in the filesystemname/filename.ipe format. The file must be stored in the root directory of a file system on the device. The value string excluding the file system location section (if any) can have a maximum of 63 characters. For more information about specifying a file, see file system management in Fundamentals Configuration Guide.
filesystem: Specifies the destination file system for the software images, in the filesystemname format.
Usage guidelines
To use the install activate command to activate software images, you must use .bin image files. If the upgrade file is an .ipe file, use this command to decompress the .ipe file before you start the upgrade.
To identify software images that are included in an .ipe file, use the display install ipe-info command.
Examples
# Decompress all.ipe to the flash memory.
<Sysname> install add flash:/all.ipe flash:
Verifying the file flash:/all.ipe on slot 1...Done.
Decompressing file boot.bin to flash:/boot.bin.......................Done.
Decompressing file system.bin to flash:/system.bin.................................Done.
install commit
Use install commit to commit software changes.
Syntax
install commit
Views
User view
Predefined user roles
network-admin
Usage guidelines
Prerequisites
Before you use this command, read the release notes to identify software image licensing requirements. Make sure the device has valid licenses for all license-based images.
Application scenarios
You must execute this command after using the following commands:
· The install activate command in an incremental upgrade.
· The install deactivate command.
· The install rollback command.
Operating mechanism
This command adds the patch image file to the startup software image list that the device used at startup.
· If the device used the main startup software image list at startup, this command adds the patch image file to the main startup software image list.
· If the device used the backup startup software image list at startup, this command adds the patch image file to the backup startup software image list.
Both the install commit and boot-loader file commands modify the main startup software image list. However, the boot-loader file command can also modify the backup startup image list and add inactive images as main startup images.
For more information about main and backup startup software images, see Fundamentals Configuration Guide.
Restrictions and guidelines
In a reboot upgrade, the install activate command modifies both the current and startup software image lists. You do not need to commit software changes.
Examples
# (In standalone mode.) Commit software changes.
<Sysname> install commit
This operation will take several minutes, please wait...........................Done.
The current software images have been saved as the startup software images.
Current software images on slot 1:
flash:/boot.bin
flash:/system.bin
Current software images on slot 2:
flash:/boot.bin
flash:/system.bin
Related commands
install activate
install deactivate
install rollback
install deactivate
Use install deactivate to deactivate feature images and patch images.
Syntax
In standalone mode:
install deactivate feature filename&<1-30> slot slot-number
install deactivate patch filename { all | slot slot-number }
In IRF mode:
install deactivate feature filename&<1-30> chassis chassis-number slot slot-number
install deactivate patch filename { all | chassis chassis-number slot slot-number }
Views
User view
Predefined user roles
network-admin
Parameters
feature: Specifies a space-separated list of up to 30 feature image files.
patch: Specifies a patch image file. You can specify only one patch image file for the command at a time. However, you can execute the command multiple times to deactivate multiple patch image files.
filename: Specifies a .bin file in the filesystemname/filename.bin format. The value string can have a maximum of 63 characters. The file system name cannot contain file system location information. For more information about specifying a file, see file system management in Fundamentals Configuration Guide.
all: Specifies all cards on which the specified patch image file has been activated. (In standalone mode.)
all: Specifies all cards on which the specified patch image file has been activated. (In IRF mode.)
slot slot-number: Specifies a card by its slot number. (In standalone mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The chassis-number argument represents the member ID of the IRF member device. The slot-number argument represents the slot number of the card. (In IRF mode.)
Usage guidelines
Prerequisites
At reboot, a subordinate device automatically synchronizes the master device's configuration and status data. You must wait for the synchronization to complete before using the install deactivate command on the subordinate device. To identify whether the synchronization is complete, use the display system stable state command. The synchronization is complete if the System State field displays Stable.
Restrictions and guidelines
You can deactivate only active feature and patch images.
Images stop running in memory immediately after they are deactivated. However, only patch images deactivated by using the install deactivate patch filename all command do not run after a reboot. To prevent other deactivated images from running after a reboot, you must commit the software change by using the install commit command.
Examples
# (In standalone mode.) Deactivate the patch images in the route-patch.bin file for a slot.
<Sysname> install deactivate patch flash:/route-patch.bin slot 1
This operation might take several minutes, please wait...Done.
# (In IRF mode.) Deactivate the patch images in the route-patch.bin file for a card.
<Sysname> install deactivate patch flash:/route-patch.bin chassis 1 slot 1
This operation might take several minutes, please wait...Done.
Related commands
display install active
display install inactive
install remove
Use install remove to delete an inactive software image file.
Syntax
In standalone mode:
install remove [ slot slot-number ] { filename | inactive }
In IRF mode:
install remove [ chassis chassis-number slot slot-number ] { filename | inactive }
Views
User view
Predefined user roles
network-admin
Parameters
slot slot-number: Specifies a card by its slot number. If you do not specify a card, this command deletes inactive software images from all cards. (In standalone mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The chassis-number argument represents the member ID of the IRF member device. The slot-number argument represents the slot number of the card. If you do not specify a card, this command deletes inactive software images from all cards. (In IRF mode.)
filename: Specifies a .bin file in the filesystemname/filename.bin format. The value string can have a maximum of 63 characters. The file must be stored in the root directory of a file system on the device. The file system name cannot contain file system location information. For more information about specifying a file, see file system management in Fundamentals Configuration Guide.
inactive: Deletes all inactive software image files in the root directories of the specified file systems.
Usage guidelines
This command permanently deletes the image files from the device. You cannot use the install rollback to command to revert the operation, or use the install abort command to abort the operation.
Examples
# Delete inactive software image file flash:/feature1.bin.
<Sysname> install remove flash:/feature1.bin
install rollback to
Use install rollback to to roll back the software to an earlier rollback point.
Syntax
install rollback to { point-id | original }
Views
User view
Predefined user roles
network-admin
Parameters
point-id: Specifies a rollback point ID. This option is supported only when there are two or more rollback points. To identify available rollback points, use the display install rollback command.
original: Rolls back to the status before any activate or deactivate operations were performed.
Restrictions and guidelines
During an incremental upgrade, the system creates a rollback point for each activate or deactivate operation of a boot, system, or feature image. The device supports a maximum of 50 rollback points. The earliest rollback point is deleted if this limit has been reached when a rollback point is created.
During a reboot upgrade, the system does not create rollback points. After the upgrade, you can roll back the software only to the status before any activate or deactivate operations were performed.
For a rollback to take effect after a reboot, you must perform a commit operation to update the main startup software image list.
After a commit operation is performed, you cannot perform a rollback.
Patch images do not support rollback.
Examples
# Roll back the software to rollback point 1.
<Sysname>install rollback to 1
This operation might take several minutes, please wait...Done.
# Roll back the software to the original software versions and observe the change made by the rollback.
<Sysname> display install active
Active packages on slot 1:
flash:/boot-t0001015.bin
flash:/system-t0001015.bin
flash:/feature1-t0001015.bin
<Sysname> display install rollback
Install rollback information 1 on slot 1:
Updating from no package
to flash:/feature1-t0001015.bin.
The output shows that currently three image files are active but only two of them are confirmed. Image file flash:/feature1-t0001015.bin is not confirmed yet.
<Sysname> install rollback to original
This operation might take several minutes, please wait...Done.
<Sysname> display install active
Active packages on slot 1:
flash:/boot-t0001015.bin
flash:/system-t0001015.bin
<Sysname> display install committed
Committed packages on slot 1:
flash:/boot-t0001015.bin
flash:/system-t0001015.bin
The output shows the SSH feature has been rolled back to the original software version. The image file flash:/feature1-t0001015.bin has been removed.
Related commands
display install rollback
install verify
Use install verify to verify the software change commit status, image integrity, and image consistency.
Syntax
install verify
Views
User view
Predefined user roles
network-admin
Usage guidelines
Application scenarios
If a software image fails the verification, perform the following tasks to resolve the problem:
· To ensure software integrity, download and install the software images again.
· To guarantee software image consistency or change software commit status, use the install activate, install deactivate, and install commit commands as appropriate.
Operating mechanism
To ensure a successful ISSU and make sure that the system can start up and operate correctly after an ISSU, execute this command to verify the following items:
· Integrity—Verify that the boot, system, and feature images are integral.
· Consistency—Verify that the same active images are running across the entire system.
· Software commit status—Verify that the active images are committed as needed.
Examples
# (In standalone mode.) Verify the software change confirmation status and software image integrity and consistency.
<Sysname> install verify
Active packages on slot 1 are the reference packages.
Packages will be compared with the reference packages.
This operation will take several minutes, please wait...
Verifying packages on slot 0:
Start to check active package completeness.
Verifying the file flash:/boot-t0001015.bin on slot 0.....................Done.
flash:/boot-t0001015.bin verification successful.
Verifying the file flash:/system-t0001015.bin on slot 0.....................Done.
flash:/system-t0001015.bin verification successful.
Start to check active package consistency.
Active packages are consistent with committed packages on their own board.
Active packages are consistent with the reference packages.
Verifying packages on slot 1:
Start to check active package completeness.
Verifying the file flash:/boot-t0001015.bin on slot 1.....................Done.
flash:/boot-t0001015.bin verification successful.
Verifying the file flash:/system-t0001015.bin on slot 1.....................Done.
flash:/system-t0001015.bin verification successful.
Start to check active package consistency.
Active packages are consistent with committed packages on their own board.
Active packages are consistent with the reference packages.
Verification is done.
# (In IRF mode.) Verify the software change confirmation status and software image integrity and consistency.
<Sysname> install verify
Active packages on chassis 1 slot 1 are the reference packages.
Packages will be compared with the reference packages.
This operation will take several minutes, please wait...
Verifying packages on chassis 1 slot 1:
Start to check active package completeness.
Verifying the file flash:/boot-t0001015.bin on chassis 1 slot 1.....................Done.
flash:/boot-t0001015.bin verification successful.
Verifying the file flash:/system-t0001015.bin on chassis 1 slot 1.....................Done.
flash:/system-t0001015.bin verification successful.
Start to check active package consistency.
Active packages are consistent with committed packages on their own board.
Active packages are consistent with the reference packages.
Verifying packages on chassis 2 slot 1:
Start to check active package completeness.
Verifying the file flash:/boot-t0001015.bin on chassis 2 slot 1.....................Done.
flash:/boot-t0001015.bin verification successful.
Verifying the file flash:/system-t0001015.bin on chassis 2 slot 1.....................Done.
flash:/system-t0001015.bin verification successful.
Start to check active package consistency.
Active packages are consistent with committed packages on their own board.
Active packages are consistent with the reference packages.
Verification is done.
issu accept
Use issu accept to accept the upgrade to a compatible version and delete the automatic rollback timer.
Syntax
issu accept
Views
User view
Predefined user roles
network-admin
Usage guidelines
Operating mechanism
The system cannot perform automatic rollback for the ISSU process after you execute this command. However, you can use the issu rollback command to perform a manual rollback.
Restrictions and guidelines
The issu accept command does not apply to an ISSU to an incompatible version.
Examples
# Accept the upgrade to a compatible version.
<Sysname> issu accept
Related commands
issu load
issu run switchover
issu commit
(In standalone mode.) Use issu commit to upgrade the original active MPU to a compatible version and complete the ISSU.
(On a dual-MPU single-chassis IRF fabric.) Use issu commit to upgrade the original active MPU to a compatible version and complete the ISSU.
(On a multichassis IRF fabric.) Use issu commit to upgrade the original master and the subordinate members that have not been upgraded and complete the ISSU upgrade.
Syntax
In standalone mode:
issu commit slot slot-number
In IRF mode (single-chassis):
issu commit chassis chassis-number slot slot-number
In IRF mode (multichassis):
issu commit chassis chassis-number
Views
User view
Predefined user roles
network-admin
Parameters
slot slot-number: Specifies the slot number of the original active MPU. (In standalone mode.)
chassis chassis-number slot slot-number: Specifies the member ID and slot number of the original active MPU. (On a single-chassis IRF fabric.)
chassis chassis-number: Specifies the member ID of the original master or a subordinate member that has not been upgraded. (On a multichassis IRF fabric.)
Usage guidelines
Prerequisites
At reboot, a subordinate device automatically synchronizes the master device's configuration and status data. You must wait for the synchronization to complete before using the issu commit command on the subordinate device. To identify whether the synchronization is complete, use the display system stable state command. The synchronization is complete if the System State field displays Stable.
Restrictions and guidelines
(In standalone mode.) (In IRF mode.) On a standalone device or a single-member IRF fabric, this command ends the ISSU process. When this command is completed, the ISSU status changes to Init, and the ISSU process cannot be rolled back.
On a multichassis IRF fabric, use this command to upgrade the original master and the subordinate members that have not been upgraded, one by one. After all members are upgraded, the ISSU status changes to Init, and the ISSU process ends and cannot be rolled back. You must wait for one upgraded subordinate member to start up again and join the IRF fabric before upgrading another subordinate member.
Examples
# (In IRF mode.) Upgrade the members that have not been upgraded during an ISSU to a compatible version. In this example, the IRF fabric has four members, and only the member with the ID 2 has been upgraded.
<Sysname> issu commit chassis 3
Copying file flash:/feature1.bin to chassis3#slot1#flash:/feature1.bin...Done.
Verifying the file flash:/feature1.bin on chassis 3 slot 1..............Done.
Upgrade summary according to following table:
flash:/feature1.bin
Running Version New Version
Test 0001015 Test 0001016
Chassis Slot Upgrade Way
3 0 Service Upgrade
3 1 Service Upgrade
3 2 Service Upgrade
3 3 Service Upgrade
3 4 Service Upgrade
Upgrading software images to compatible versions. Continue? [Y/N]:y
This operation might take several minutes, please wait...Done.
<Sysname> issu commit chassis 4
Copying file flash:/feature1.bin to chassis4#slot0#flash:/feature1.bin...Done.
Verifying the file flash:/feature1.bin on chassis 4 slot 0..............Done.
Copying file flash:/feature1.bin to chassis4#slot1#flash:/feature1.bin...Done.
Verifying the file flash:/feature1.bin on chassis 4 slot 1..............Done
Upgrade summary according to following table:
flash:/feature1.bin
Running Version New Version
Test 0001015 Test 0001016
Chassis Slot Upgrade Way
4 0 Service Upgrade
4 1 Service Upgrade
4 2 Service Upgrade
4 3 Service Upgrade
4 4 Service Upgrade
Upgrading software images to compatible versions. Continue? [Y/N]:y
This operation might take several minutes, please wait...Done.
<Sysname> issu commit chassis 1
Copying file flash:/feature1.bin to chassis1#slot0#flash:/feature1.bin...Done.
Verifying the file flash:/feature1.bin on chassis 1 slot 0..............Done.
Copying file flash:/feature1.bin to chassis1#slot1#flash:/feature1.bin...Done.
Verifying the file flash:/feature1.bin on chassis 1 slot 1..............Done.
Upgrade summary according to following table:
flash:/feature1.bin
Running Version New Version
Test 0001015 Test 0001016
Chassis Slot Upgrade Way
1 0 Service Upgrade
1 1 Service Upgrade
1 2 Service Upgrade
1 3 Service Upgrade
1 4 Service Upgrade
Upgrading software images to compatible versions. Continue? [Y/N]:y
This operation might take several minutes, please wait...Done.
# (In IRF mode.) Upgrade the original active MPU to a compatible version. (In this example, the IRF fabric has a single member and the member has two MPUs.)
<Sysname> issu commit chassis 1 slot 0
Verifying the file flash:/feature1.bin on chassis 1 slot 1..............Done.
Upgrade summary according to following table:
flash:/feature1.bin
Running Version New Version
Test 0001015 Test 0001016
Chassis Slot Upgrade Way
1 0 Service Upgrade
Upgrading software images to compatible versions. Continue? [Y/N]:y
This operation might take several minutes, please wait...Done.
# (In IRF mode.) Finish the upgrade to a compatible version. (In this example, the IRF fabric has a single member and the member has only one MPU.)
<Sysname> issu commit chassis 1 slot 0
For information about the command output, see Table 5.
Related commands
issu accept
issu load
issu run switchover
issu load
(On a standalone device or single-chassis IRF fabric.) Use issu load to upgrade the standby MPU and configure the new images as main startup software images for the MPU.
(On a multichassis IRF fabric.) Use issu load to upgrade subordinate members and configure the new images as main startup software images for those members.
Syntax
In standalone mode:
issu load file { boot filename | system filename | feature filename&<1-30> | patch filename&<1-30> } * slot slot-number [ reboot ]
issu load file ipe ipe-filename slot slot-number [ patch filename&<1-30> ] [ reboot ]
In IRF mode (single-chassis):
issu load file { boot filename | system filename | feature filename&<1-30> | patch filename&<1-30> } * chassis chassis-number slot slot-number [ reboot ]
issu load file ipe ipe-filename [ patch filename&<1-30> ] chassis chassis-number slot slot-number [ reboot ]
In IRF mode (multichassis):
issu load file { boot filename | system filename | feature filename&<1-30> | patch filename&<1-30> } * chassis chassis-number&<1-3> [ reboot ]
issu load file ipe ipe-filename [ patch filename&<1-30> ] chassis chassis-number&<1-3> [ reboot ]
Views
User view
Predefined user roles
network-admin
Parameters
boot: Specifies a boot image file.
system: Specifies a system image file.
feature: Specifies a space-separated list of up to 30 feature image files.
patch: Specifies a space-separated list of up to 30 patch image files. You can specify both incremental and non-incremental patch image files. The device can have a maximum of 30 incremental patch image files. Because the boot image, system image, and feature images each can have only one non-incremental patch image file, the device can have a maximum of 16 non-incremental patch image files. For more information about incremental and non-incremental patch images, see software upgrade in Fundamentals Configuration Guide.
filename: Specifies a .bin file in the filesystemname/filename.bin format. The file must be stored in the root directory of a file system on the active MPU (in standalone mode) or global active MPU (in IRF mode). The value string excluding the file system location section (if any) can have a maximum of 63 characters. For more information about specifying a file, see file system management in Fundamentals Configuration Guide.
ipe-filename: Specifies an .ipe file in the filesystemname/filename.ipe format. The file must be stored in the root directory of a file system on the active MPU (in standalone mode) or global active MPU (in IRF mode). The value string excluding the file system location section (if any) can have a maximum of 63 characters. For more information about specifying a file, see file system management in Fundamentals Configuration Guide.
slot slot-number: Specifies the slot number of the standby MPU. If the device has only one MPU, enter the slot number of the MPU to upgrade the entire device. (In standalone mode.)
chassis chassis-number slot slot-number: Specifies the member ID and slot number of the standby MPU. If the member has only one MPU, enter the member ID and slot number of the MPU to upgrade the entire fabric. (On a single-chassis IRF fabric.)
chassis chassis-number: Specifies the member ID of a subordinate member. For a compatible upgrade, you can specify only one member ID. For an incompatible upgrade, you can specify a space-separated list of up to three member IDs. (On a multichassis IRF fabric.)
reboot: Uses the reboot method for the upgrade. For an incremental upgrade, specify this keyword if you want to use the reboot upgrade method. If you do not specify this keyword, the recommended upgrade method is used.
Usage guidelines
Prerequisites
At reboot, a subordinate device automatically synchronizes the master device's configuration and status data. You must wait for the synchronization to complete before using the issu load command on the subordinate device. To identify whether the synchronization is complete, use the display system stable state command. The synchronization is complete if the System State field displays Stable. (In IRF mode.)
Operating mechanism
(Standalone device or single-chassis IRF fabric.) This command performs the following operations:
· Checks the version compatibility.
· Identifies the upgrade method.
· Loads the new images to upgrade the specified MPU.
· Sets the new images as the main startup software images for the specified MPU so the upgrade can survive a reboot.
(Multichassis IRF fabric.) This command performs the following operations:
· Checks the version compatibility.
· Identifies the upgrade method.
· Loads the new images to upgrade the specified member devices.
· Sets the new images as the main startup software images for the specified member devices so the upgrade can survive a reboot.
Restrictions and guidelines
The software images for the device are digitally signed. The system verifies the digital signatures of the specified software images for authenticity and integrity before it sets or loads them as main startup images. If the digital signature verification fails, the system will not set or load the specified images as main startup images and you will receive a digital signature verification failure message.
If you upgrade images other than patch images, the upgrade can succeed only if the boot, system, and feature images in the startup software image list are the same version after the upgrade.
To ensure a successful upgrade, maintain version consistency across the boot, system, and feature images. If you are upgrading some of the images, make sure the specified upgrade images are the same version as the images not to be upgraded in the startup software image list.
|
NOTE: Be aware that using this command to upgrade the boot, system, or feature image will cause the patch images (if any) to be deleted from the startup software image list. Install the patch images as needed if the upgrade software version has not removed the issues that are resolved by using the patches. |
If this command fails, perform the following tasks:
1. If some features are not needed anymore, disable the features and use the install deactivate command to uninstall the feature images.
2. Obtain the correct version of the images. Make sure all images in the startup software image list will be the same version after the upgrade.
3. Execute this command to activate the images.
Examples
# (In IRF mode.) Upgrade subordinate member 2 with image file flash:/version.ipe, and install a patch image file for the feature image.
<Sysname> issu load file ipe flash:/version-t0001015.ipe patch flash:/system-patch1.bin chassis 2
This operation will delete the rollback point information for the previous upgrade and maybe get unsaved configuration lost. Continue? [Y/N]:y
Verifying image file flash:/version-t0001015.ipe on chassis 2 slot 0.................Done.
Verifying image file flash:/version-t0001015.ipe on chassis 2 slot 1.................Done.
Decompressing file BOOT-T0001015.bin to flash:/BOOT-E1133.bin.............Done.
Decompressing file SYSTEM-T0001015.bin to flash:/SYSTEM-E1133.bin...........Done.
Decompressing file system-patch1.bin to flash:/system-patch1.bin...........Done.
Decompression completed.
Do you want to delete flash:/version-t0001015.ipe now? [Y/N]:n
Upgrade summary according to following table:
flash:/BOOT-T0001015.bin
Running Version New Version
Test 0001015 Test 0001016
flash:/SYSTEM-E1133.bin
Running Version New Version
Test 0001015 Test 0001016
flash:/system-patch1.bin
Running Version New Version
None Test 0001016
Chassis Slot Upgrade Way
2 0 Reboot
2 1 Reboot
Upgrading software images to compatible versions. Continue? [Y/N]:y
This operation might take several minutes, please wait...Done.
Table 7 Command output
Field |
Description |
Verifying the file |
The system was verifying the validity of the file. |
Copying file |
(In IRF mode.) The system was copying the upgrade file to a global standby MPU. This field is displayed if you specified a global standby MPU for the command. |
Upgrade Way |
ISSU method: · Service Upgrade. · File Upgrade. · Reboot. This field is displayed only for an upgrade to a compatible version. For more information about ISSU methods, see Fundamentals Configuration Guide. |
issu quit
Use issu quit to terminate the ongoing ISSU process forcibly.
Syntax
issu quit
Views
System view
Predefined user roles
network-admin
Usage guidelines
Application scenarios
Use this command to terminate the ISSU process if one of the following exceptions occurs and you cannot perform an upgrade or rollback:
· The ISSU status is not Init but the upgrade has stopped.
· The ISSU status is Init but the upgrade has not completed.
Restrictions and guidelines
After using this command to terminate the ISSU process, identify whether the requirements for an ISSU are met. If yes, use boot-loader or install commands as needed to restore the device to the state prior to the terminated ISSU and then try an ISSU again. If the ISSU fails again, contact the technical support.
Examples
# Terminate the ongoing ISSU process forcibly.
<Sysname> system-view
[Sysname] issu quit
This command stops the ongoing ISSU process. Execute this command only under the guidance of the technical support. Continue? [Y/N]:y
Succeeded.
Related commands
install activate
issu load
issu rollback
Use issu rollback to cancel the ISSU and roll back to the original software versions.
Syntax
issu rollback
Views
User view
Predefined user roles
network-admin
Application scenarios
The device supports automatic rollback and manual rollback. This command performs a manual rollback.
You can perform a manual rollback while an ISSU is in one of the following states:
· Loaded.
· Switching (during an upgrade to a compatible version).
· Switchover (during an upgrade to a compatible version).
· Accepted.
Restrictions and guidelines
(In IRF mode.) In Switching state, a rollback during a reboot upgrade and an automatic rollback during an incompatible upgrade can result in the following situations:
· The upgraded subordinate members reboot.
· The master might also reboot because of a master/subordinate switchover, resulting in service outage.
· After the rollback, the member devices run the software that they run before the upgrade, but their master/subordinate roles might not be the same as before.
As a best practice, make sure the automatic rollback timer is long enough, and do not perform a rollback while an ISSU is in Switching state.
Examples
# Roll back to the original software versions.
<Sysname> issu rollback
This command will quit the ISSU process and roll back to the previous version. Continue? [Y/N]:y
Related commands
issu accept
issu commit
issu load
issu run switchover
issu rollback-timer
Use issu rollback-timer to set the automatic rollback timer.
Use undo issu rollback-timer to restore the default.
Syntax
issu rollback-timer minutes
undo issu rollback-timer
Default
The automatic rollback timer is set to 45 minutes.
Views
System view
Predefined user roles
network-admin
Parameters
minutes: Specifies the automatic rollback interval, in the range of 0 to 120 minutes. Setting it to 0 disables automatic rollback.
Usage guidelines
Application scenarios
The automatic software version rollback feature is complicated. As a best practice, disable this feature before performing an ISSU.
Restrictions and guidelines
The system starts the automatic rollback timer when you execute the issu run switchover command in a scenario where automatic rollback is supported. If you do not execute the issu accept or issu commit command before the timer expires, the system automatically rolls back to the software version used before the ISSU.
Change to the automatic rollback interval does not take effect on the ongoing ISSU process.
Examples
# Set the automatic rollback timer to 50 minutes.
<Sysname> system-view
[Sysname] issu rollback-timer 50
Related commands
issu rollback
issu run switchover
Use issu run switchover to perform an ISSU switchover.
Syntax
issu run switchover
Views
User view
Predefined user roles
network-admin
Usage guidelines
Prerequisites
At reboot, a subordinate device automatically synchronizes the master device's configuration and status data. You must wait for the synchronization to complete before using the issu run switchover command on the subordinate device. To identify whether the synchronization is complete, use the display system stable state command. The synchronization is complete if the System State field displays Stable.
Operating mechanism
Use this command only on a multichassis IRF fabric or a dual-MPU single-member IRF fabric.
· (On a dual-MPU single-chassis IRF fabric.) The function of this command is as follows:
¡ For a compatible upgrade, this command performs operations depending on the ISSU method.
- Incremental upgrade—Performs a process-level active/standby switchover for the processes to be upgraded, and upgrades the LPUs and switching fabric modules.
- Reboot upgrade or ISSU upgrade—Reboots the current active MPU with the old software version and upgrades the LPUs and switching fabric modules. The upgraded MPU then becomes the new active MPU.
¡ For an incompatible upgrade, this command reboots the current active MPU, the LPUs, and the switching fabric modules to use the new software version. After the reboot, the following operations take place in turn:
- The upgraded MPU becomes the new active MPU.
- The original active MPU, the LPUs, and the switching fabric modules are upgraded.
- The ISSU process ends.
· (On a multichassis IRF fabric.) The function of this command is as follows:
¡ For a compatible upgrade, this command performs operations depending on the ISSU method.
- Incremental upgrade—Performs a process-level master/subordinate switchover for the processes to be upgraded.
- Reboot upgrade—Reboots the current master with the old software version to cause the upgraded subordinate member to become the new master.
¡ For an incompatible upgrade, the issu load command splits the IRF fabric into two fabrics, with the upgraded members forming a new fabric. The issu run switchover command reboots the old IRF fabric's members with the upgrade images to join the new IRF fabric as subordinate members.
Restrictions and guidelines
When you execute the issu run switchover command during an ISSU to a compatible version, the system starts the automatic rollback timer. If you do not execute the issu accept or issu commit command before the timer expires, the system automatically rolls back to the original software versions.
During a reboot upgrade to a compatible version, the LPUs and switching fabric modules reboot to load the new software from the upgraded MPU. A transient service outage occurs on the cards.
Examples
# (In IRF mode.) Perform a switchover.
<Sysname> issu run switchover
Upgrade summary according to following table:
flash:/boot-t0001015.bin
Running Version New Version
Test 0001015 Test 0001016
flash:/system-t0001015.bin
Running Version New Version
Test 0001015 Test 0001016
Chassis Slot Switchover Way
2 1 Global active standby MPU switchover
Upgrading software images to compatible versions. Continue? [Y/N]:y
This operation might take several minutes, please wait...Done.
Table 8 Command output
Field |
Description |
Switchover Way |
Switchover method: · Active standby process switchover—Switch from the active process to the standby process. · (In IRF mode.) Global active standby MPU switchover—Switch from the global active MPU to a global standby MPU. |
For more information about the command output, see Table 5.
Related commands
issu load
reset install log-history oldest
Use reset install log-history oldest to clear ISSU log entries.
Syntax
reset install log-history oldest log-number
Views
User view
Predefined user roles
network-admin
Parameters
log-number: Specifies the number of ISSU log entries to be deleted.
Usage guidelines
This command clears the specified number of log entries, beginning with the oldest log entry.
Examples
# Clear the two oldest ISSU log entries.
<Sysname> reset install log-history oldest 2
Related commands
display install log
reset install rollback oldest
Use reset install rollback oldest to clear ISSU rollback points.
Syntax
reset install rollback oldest point-id
Views
User view
Predefined user roles
network-admin
Parameters
point-id: Specifies a rollback point by its ID.
Usage guidelines
CAUTION: This command clears the specified rollback point and all rollback points earlier than the specified rollback point. |
Examples
# Clear rollback point 2 and all rollback points older than rollback point 2.
<Sysname> reset install rollback oldest 2
Related commands
display install rollback