- Table of Contents
-
- H3C SecPath M9000 Multi Service Security Gateway Series Installation Guides-6W106
- 00-Preface
- 01-Chapter 1 Chassis views
- 01-Chapter 1 Preparing for Installation
- 02-Chapter 2 Installing the Gateway
- 03-Chapter 3 Logging in to the Gateway and Configuring Basic Settings
- 04-Chapter 4 Troubleshooting
- 06-Chapter 6 Replacing FRUs
- 07-Appendix A FRUs and Compatibility Matrixes
- 08-Appendix B Technical Specifications
- 09-Appendix C LEDs
- 10-Appendix D Slot arrangement and interface numbering
- 11-Appendix E Cables
- 12-Appendix F Cabling Recommendations
- 13-Appendix G Repackaging the Gateway
- Related Documents
-
Title | Size | Download |
---|---|---|
10-Appendix D Slot arrangement and interface numbering | 557.66 KB |
Appendix D Slot arrangement and interface numbering
Card slot arrangement
Figure 1 Card slot arrangement of the M9006
Figure 2 Card slot arrangement of the M9010/M9010-GM/M9016-V (M9010 as an example)
Figure 3 Card slot arrangement of the M9014
Model |
Card slot arrangement |
Slot mark location |
M9006 |
· MPU slots: slots 0 and 1 · Slots for interface switch modules, interface modules, and service modules: slots 2 to 5 |
At the right edge of the slot |
M9010 M9010-GM M9016-V |
· MPU slots: slots 4 and 5 · Slots for interface switch modules, interface modules, and service modules: slots 0 to 3 and slots 6 to 9 |
At the top edge of the slot |
M9014 |
· MPU slots: slots 6 and 7 · Slots for interface switch modules, interface modules and service modules: slots 0 to 5 and slots 8 to 13 |
At the right edge of the slot |
|
NOTE: For the interface switch module slots, interface module slots, and service module slots, see the card manuals that come with the cards. |
Example
You can execute the display device command to view the slot arrangement on the device.
<Sysname> display device
Slot NO Brd Type Brd Status Subslot Sft Ver Patch Ver
0 NSQM2PUCO Master 0 M9006-9153P05 None
Interface numbering
The gateway provides many types of interfaces, including console, M-GigabitEthernet, GigabitEthernet, Ten-GigabitEthernet, Forty-GigabitEthernet, Hundred-GigabitEthernet, blade, aggregate, tunnel, Virtual-Template, and VLAN interfaces.
The numbering of the gateway interfaces varies by the gateway mode.
· Standalone mode—interface-type X/Y/Z.
· IRF mode—interface-type W/X/Y/Z.
Where,
· interface-type—Type of the interface such as GigabitEthernet interface.
· W—IRF member device ID.
· X—Number of the slot where the card resides. For more information about the slot number on the gateway, see Table 1.
· Y—Number of the slot where the subcard resides on the interface switch module. The value is 1 or 2.
· Z—Number of the port on the card. The number starts from 1 for each port type.
The management port is numbered M-GigabitEthernet0/0/0 when the gateway operates in standalone mode and M-GigabitEthernet1/0/0/0 when the gateway operates in IRF mode.
Example
· The gateway operates in standalone mode and has an interface module installed in slot 2. The interfaces on the interface module are numbered as shown in the output of the display interface GigabitEthernet brief command.
<Sysname> display interface GigabitEthernet brief
Brief information on interface(s) under route mode:
Link: ADM - administratively down; Stby - standby
Protocol: (s) - spoofing
Interface Link Protocol Main IP Description
GE2/0/1 DOWN DOWN 192.168.1.1/24
GE2/0/2 DOWN DOWN --
GE2/0/3 DOWN DOWN --
GE2/0/4 DOWN DOWN --
GE2/0/5 DOWN DOWN --
……
GE2/0/47 DOWN DOWN --
GE2/0/48 DOWN DOWN --
· The gateway operates in IRF mode and its IRF member device ID is 1. An interface module is installed in slot 2 of the gateway. The interfaces on the interface module are numbered as shown in the output of the display interface GigabitEthernet brief command.
<Sysname> display interface GigabitEthernet brief
Brief information on interface(s) under route mode:
Link: ADM - administratively down; Stby - standby
Protocol: (s) - spoofing
Interface Link Protocol Main IP Description
GE1/2/0/1 DOWN DOWN 192.168.1.1
GE1/2/0/2 DOWN DOWN --
GE1/2/0/3 DOWN DOWN --
GE1/2/0/4 DOWN DOWN --
GE1/2/0/5 DOWN DOWN --
……
GE1/2/0/47 DOWN DOWN --
GE1/2/0/48 DOWN DOWN --