- Table of Contents
- Related Documents
-
Title | Size | Download |
---|---|---|
03-LEDs | 499.66 KB |
3 LEDs
Routing and switching unit LEDs
RSU-300
Figure3-1 RSU-300 routing and switching unit LEDs
(1) System status LED (SYS) |
(2) Running status LED (RUN) |
(3) Active/standby status LED (ACT) |
|
(4) Management Ethernet port LED (MANAGEMENT) |
(5) Clock synchronization LED (SYNC) |
||
(6) High severity alarm LED (ALARM H) |
(7) Low severity alarm LED (ALARM L) |
||
Table3-1 RSU-300 routing and switching unit LED descriptions
LED |
Status |
Descriptions |
SYS |
Flashing green (eight times per second) |
· BIOS stage—BIOS is starting up. · BootWare stage—The system software image is being decompressed. |
Flashing yellow (once per second) |
· BIOS stage—The memory does not exist or system initialization has failed. · BootWare stage—The SDRAM has failed the POST. |
|
Flashing yellow (eight times per second) |
The extended segment does not exist (BIOS stage). |
|
Steady green |
· BootWare stage—The SDRAM is being tested. · Comware stage—The kernel is starting up. |
|
Flashing green (once per second) |
The Comware system is starting up or is operating correctly (Comware stage). |
|
Steady yellow |
The boot.bin file does not exist (BootWare stage). |
|
Off |
A system hardware failure has occurred. |
|
RUN |
Flashing green (once per second) |
BIOS has started up and BootWare is starting up. |
Flashing red (once per second) |
BIOS is starting up. |
|
Steady green |
The Comware system is starting up or is operating correctly. |
|
Off |
No power is present. |
|
ACT |
Steady green |
The routing and switching unit is in active mode. |
Flashing green (eight times per second) |
The routing and switching units are establishing active and standby roles. |
|
Off |
The routing and switching unit is in standby mode. |
|
MANAGEMENT |
Steady green |
A 100 Mbps link is present on the port. |
Flashing green |
The port is sending or receiving data at 100 Mbps. |
|
Off |
No link is present on the port. |
|
SYNC |
Steady green |
The system clock is in free-run mode and no clock source is specified for the system clock. |
Steady yellow |
The system clock is in traced mode and is tracing a clock source in the clock source priority list. |
|
Off |
The system clock is in locked mode, and the PTP clock is tracing a clock source. |
|
ALARM H |
Steady red |
A high severity alarm has occurred on the device. |
Off |
No high severity alarm has occurred on the device. |
|
ALARM L |
Steady yellow |
A low severity alarm has occurred on the device. |
Off |
No low severity alarm has occurred on the device. |
RSU-400
Figure3-2 RSU-400 routing and switching unit LEDs
(1) System status LED (SYS) |
(2) Running status LED (RUN) |
(3) Active/standby status LED (ACT) |
|
(4) Management Ethernet port LED (MANAGEMENT) |
(5) Clock synchronization LED (SYNC) |
||
(6) High severity alarm LED (ALARM H) |
(7) Low severity alarm LED (ALARM L) |
||
Table3-2 RSU-400 routing and switching unit LED descriptions
LED |
Status |
Descriptions |
SYS |
Flashing green (eight times per second) |
· BIOS stage—BIOS is starting up. · BootWare stage—The system software image is being decompressed. |
Flashing yellow (once per second) |
· BIOS stage—The memory does not exist or system initialization has failed. · BootWare stage—The SDRAM has failed the POST. |
|
Flashing yellow (eight times per second) |
The extended segment does not exist (BIOS stage). |
|
Steady green |
· BootWare stage—The SDRAM is being tested. · Comware stage—The kernel is starting up. |
|
Flashing green (once per second) |
The Comware system is starting up or is operating correctly (Comware stage). |
|
Steady yellow |
The boot.bin file does not exist (BootWare stage). |
|
Off |
A system hardware failure has occurred. |
|
RUN |
Flashing green (eight times per second) |
The routing and switching unit is collecting diagnostic information. |
Flashing green (once per second) |
BIOS has started up and BootWare is starting up. |
|
Flashing red (once per second) |
BIOS is starting up. |
|
Steady green |
The Comware system is starting up or is operating correctly. |
|
Off |
No power is present. |
|
ACT |
Steady green |
The routing and switching unit is in active mode. |
Flashing green (eight times per second) |
The routing and switching units are establishing active and standby roles. |
|
Off |
The routing and switching unit is in standby mode. |
|
MANAGEMENT |
Steady green |
A 100 Mbps link is present on the port. |
Flashing green |
The port is sending or receiving data at 100 Mbps. |
|
Off |
No link is present on the port. |
|
SYNC |
Steady green |
· The system clock is in free running mode and no clock source priority list is configured for the system clock. · The system clock is tracing a clock source in the clock source priority list. · The system clock is in time synchronization mode, and the PTP clock and system clock are tracing clock sources. |
Steady yellow |
All the clock sources except for the internal source have been lost, and system clock works in holdover or free running mode. |
|
Off |
The system is not powered on, or synchronization is not performed during the startup process of the module. |
|
ALARM H |
Steady red |
A high severity alarm has occurred on the device. |
Off |
No high severity alarm has occurred on the device. |
|
ALARM L |
Steady yellow |
A low severity alarm has occurred on the device. |
Off |
No low severity alarm has occurred on the device. |
RSU-400S
Figure3-3 RSU-400S routing and switching unit LEDs
(1) System status LED (SYS) |
(2) Running status LED (RUN) |
(3) Active/standby status LED (ACT) |
|
(4) Management Ethernet port LED (MANAGEMENT) |
(5) Clock synchronization LED (SYNC) |
||
(6) High severity alarm LED (ALARM H) |
(7) Low severity alarm LED (ALARM L) |
||
Table3-3 RSU-400S routing and switching unit LED descriptions
LED |
Status |
Descriptions |
SYS |
Flashing green (eight times per second) |
· BIOS stage—BIOS is starting up. · BootWare stage—The system software image is being decompressed. |
Flashing yellow (once per second) |
· BIOS stage—The memory does not exist or system initialization has failed. · BootWare stage—The SDRAM has failed the POST. |
|
Flashing yellow (eight times per second) |
The extended segment does not exist (BIOS stage). |
|
Steady green |
· BootWare stage—The SDRAM is being tested. · Comware stage—The kernel is starting up. |
|
Flashing green (once per second) |
The Comware system is starting up or is operating correctly (Comware stage). |
|
Steady yellow |
The boot.bin file does not exist (BootWare stage). |
|
Off |
A system hardware failure has occurred. |
|
RUN |
Flashing green (eight times per second) |
The routing and switching unit is collecting diagnostic information. |
Flashing green (once per second) |
BIOS has started up and BootWare is starting up. |
|
Flashing red (once per second) |
BIOS is starting up. |
|
Steady green |
The Comware system is starting up or is operating correctly. |
|
Off |
No power is present. |
|
ACT |
Steady green |
The routing and switching unit is in active mode. |
Flashing green (eight times per second) |
The routing and switching units are establishing active and standby roles. |
|
Off |
The routing and switching unit is in standby mode. |
|
MANAGEMENT |
Steady green |
A 100 Mbps link is present on the port. |
Flashing green |
The port is sending or receiving data at 100 Mbps. |
|
Off |
No link is present on the port. |
|
SYNC |
Steady green |
· The system clock is in free running mode and no clock source priority list is configured for the system clock. · The system clock is tracing a clock source in the clock source priority list. · The system clock is in time synchronization mode, and the PTP clock and system clock are tracing clock sources. |
Steady yellow |
All the clock sources except for the internal source have been lost, and system clock works in holdover or free running mode. |
|
Off |
The system is not powered on, or synchronization is not performed during the startup process of the module. |
|
ALARM H |
Steady red |
A high severity alarm has occurred on the device. |
Off |
No high severity alarm has occurred on the device. |
|
ALARM L |
Steady yellow |
A low severity alarm has occurred on the device. |
Off |
No low severity alarm has occurred on the device. |
Interface module LEDs
The router supports HRIC interface modules. For more information of the HRIC interface module LEDs, see H3C RA5300 Router Interface Module Manual.
Fan tray LEDs
FAN-60-6-A
Figure3-4 FAN-60-6-A fan tray LEDs
(1) Fan tray status LED (FAN) |
Table3-4 Fan tray LED descriptions
LED |
Status |
Descriptions |
FAN |
Steady green |
The fan tray is operating correctly. |
Steady red |
The fan tray is faulty. |
|
Off |
No power is present on the fan tray, or the fan tray is not in place. |
Power supply LEDs
Figure3-5 Power supply LEDs
(1) Power supply status LED (PWR) |
Table3-5 Power supply LED descriptions
LED |
Status |
Descriptions |
PWR |
Steady green |
The power supply is operating correctly. |
Off |
No power is present. |