H3C Fixed Port Campus Switches Configuration Examples-B70D022-6W100

HomeSupportConfigure & DeployConfiguration ExamplesH3C Fixed Port Campus Switches Configuration Examples-B70D022-6W100
Table of Contents
Related Documents
28-MLD Snooping Configuration Examples
Title Size Download
28-MLD Snooping Configuration Examples 148.84 KB

Introduction

This document introduces MLD snooping configuration examples.

Prerequisites

This document is not restricted to specific software or hardware versions.

The configuration examples in this document were created and verified in a lab environment, and all the devices were started with the factory default configuration. When you are working on a live network, make sure you understand the potential impact of every command on your network.

This document assumes that you have basic knowledge of MLD snooping.

Example: Configuring IPv6 multicast group policies

Network configuration

As shown in Figure 1:

·     Router A runs MLDv1 and acts as the MLD querier in VLAN 100.

·     Switch A runs MLDv1 snooping.

Configure IPv6 multicast group policies on Switch A so that Host A and Host B receive only the IPv6 multicast data addressed to IPv6 multicast group FF1E::101.

Figure 1 Network diagram

 

Analysis

To meet the network requirements, you must perform the following tasks:

·     To prevent Switch A from flooding MLDv1 packets in VLAN 100, specify MLD snooping version 2 in VLAN 100. By default, MLDv1 snooping runs on the device. MLDv1 snooping processes only MLDv1 packets and floods MLDv2 packets in a VLAN.

·     To prevent receiver hosts in VLAN 100 from receiving IPv6 multicast data addressed to other groups, enable dropping unknown IPv6 multicast data in VLAN 100.

·     To configure an IPv6 multicast group policy, specify an IPv6 basic ACL and create ACL rules to define the groups you want the receiver hosts to join.

Applicable hardware and software versions

The following matrix shows the hardware and software versions to which this configuration example is applicable:

 

Hardware

Software version

S6520XE-HI switch series

Supported in Release 11xx

S5560X-EI switch series

Supported in Release 111x

S5500V2-EI switch series

Supported in Release 111x

MS4520V2-30F switch

Supported in Release 111x

S5560S-EI switch series

S5560S-SI switch series

Supported in Release 612x

S5130S-HI switch series

S5130S-EI switch series

S5130S-SI switch series

S5130S-LI switch series

Supported in Release 612x

S5120V2-SI switch series

S5120V2-LI switch series

Supported in Release 612x

S3100V3-EI switch series

S3100V3-SI switch series

Supported in Release 612x

S5110V2 switch series

Supported in Release 612x

S5110V2-SI switch series

Supported in Release 612x

S5000V3-EI switch series

Supported in Release 612x

S5000E-X switch series

Supported in Release 612x

WAS6000 switch series

Supported in Release 612x

E128C switch

E152C switch

E500C switch series

E500D switch series

Supported in Release 612x

MS4520V2 switch series (except the MS4520V2-30F switch)

Supported in Release 612x

MS4320V2 switch series

MS4300V2 switch series

MS4320 switch series

MS4200 switch series

Supported in Release 612x

WS5850-WiNet switch series

Supported in Release 612x

WS5820-WiNet switch series

WS5810-WiNet switch series

Supported in Release 612x

 

Restrictions and guidelines

When you configure IPv6 multicast group polices, follow these restrictions and guidelines:

·     You must globally enable MLD snooping in system view before you enable MLD snooping for a VLAN in VLAN view.

·     IPv6 multicast group filtering denies all groups if the specified ACL does not exist or the ACL does not have any rules.

Procedures

1.     Assign an IPv6 address and prefix length to each interface on the routers in the IPv6 PIM-DM domain. (Details not shown.)

2.     Configure an IPv6 unicast routing protocol on the routers in the IPv6 PIM-DM domain. (Details not shown.)

3.     Enable IPv6 multicast routing globally on the routers in the IPv6 PIM-DM domain. (Details not shown.)

4.     Enable IPv6 PIM-DM for the interfaces through which routers connects with each other on the routers in the IPv6 PIM-DM domain. (Details not shown.)

5.     Configure Switch A:

# Enable MLD snooping globally.

<SwitchA> system-view

[SwitchA] mld-snooping

[SwitchA-mld-snooping] quit

# Create VLAN 100, and assign GigabitEthernet 1/0/1 through GigabitEthernet 1/0/4 to this VLAN.

[SwitchA] vlan 100

[SwitchA-vlan100] port gigabitethernet 1/0/1 to gigabitethernet 1/0/4

# In VLAN 100, enable MLD snooping, specify MLD snooping version 2, and enable dropping unknown IPv6 multicast data.

[SwitchA-vlan100] mld-snooping enable

[SwitchA-vlan100] mld-snooping version 2

[SwitchA-vlan100] mld-snooping drop-unknown

[SwitchA-vlan100] quit

# Configure an IPv6 multicast group policy for VLAN 100 so that receiver hosts in this VLAN can join only IPv6 multicast group FF1E::101.

[SwitchA] acl ipv6 basic 2001

[SwitchA-acl-ipv6-basic-2001] rule permit source ff1e::101 128

[SwitchA-acl-ipv6-basic-2001] quit

[SwitchA] mld-snooping

[SwitchA–mld-snooping] group-policy 2001 vlan 100

[SwitchA–mld-snooping] quit

Verifying the configuration

# Send MLD reports from Host A and Host B to join IPv6 multicast groups FF1E::101 and FF1E::202. (Details not shown.)

# Send IPv6 multicast data from the source to IPv6 multicast groups FF1E::101 and FF1E::202. (Details not shown.)

# Display dynamic MLD snooping group entries for VLAN 100 on Switch A.

[SwitchA] display mld-snooping group vlan 100

Total 1 entries.

 

VLAN 100: Total 1 entries.

  (::, FF1E::101)

    Host slots (1 in total):

      3

    Host ports (2 in total):

      GE1/0/3         (00:03:23)

      GE1/0/4         (00:04:10)

The output shows that Host A and Host B have joined IPv6 multicast group FF1E::101 through member ports GigabitEthernet 1/0/4 and GigabitEthernet 1/0/3. Host A and Host B do not join IPv6 multicast group FF1E::202. The IPv6 multicast group policy has taken effect.

Configuration files

IMPORTANT

IMPORTANT:

The port link-mode bridge command is available only on the following switches:

·     S6520XE-HI switch series.

·     S5560X-EI switch series.

·     S5500V2-EI switch series.

·     MS4520V2-30F switch.

 

Switch A:

#

acl ipv6 number 2001

 rule 0 permit source FF1E::101/128

#

mld-snooping

 group-policy 2001 vlan 100

#

vlan 100

 mld-snooping enable

 mld-snooping version 2

 mld-snooping drop-unknown

#

interface GigabitEthernet1/0/1

 port link-mode bridge

 port access vlan 100

#

interface GigabitEthernet1/0/2

 port link-mode bridge

 port access vlan 100

#

interface GigabitEthernet1/0/3

 port link-mode bridge

 port access vlan 100

#

interface GigabitEthernet1/0/4

 port link-mode bridge

 port access vlan 100

#

Example: Configuring MLD snooping static ports

Network configuration

As shown in Figure 2:

·     All switches in VLAN 100 run MLD snooping.

·     Router A runs MLDv1 and acts as the MLD querier.

·     STP runs in VLAN 100. The direct route between Switch A and Switch B or the route from Switch A to Switch B with Switch C as the intermediate device is blocked to avoid loops.

Configure MLD snooping static ports to meet the following requirements:

·     IPv6 multicast data uninterruptedly flows to Host A and Host B after a link switchover occurs between Switch A and Switch B.

·     Host A and Host B permanently receive the IPv6 multicast data addressed to IPv6 multicast group FF1E::101.

Figure 2 Network diagram

 

Analysis

To meet the network requirements, you must perform the following tasks:

·     By default, when a link switchover occurs, multicast data can flow along the new link after a minimum of one MLD query-response cycle. Multicast delivery is interrupted during this process.

Configure GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3 on Switch A, GigabitEthernet 1/0/4 on Switch B, and GigabitEthernet 1/0/2 on Switch C as static router ports. Then, IPv6 multicast data will always be forwarded to these ports, and multicast delivery is uninterrupted.

·     Configure GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3 on Switch B as static member ports of IPv6 multicast group FF1E::101. Then, IPv6 multicast data for the group will always be forwarded out of these ports, and Host A and Host B can always receiver the data.

Applicable hardware and software versions

The following matrix shows the hardware and software versions to which this configuration example is applicable:

 

Hardware

Software version

S6520XE-HI switch series

Supported in Release 11xx

S5560X-EI switch series

Supported in Release 111x

S5500V2-EI switch series

Supported in Release 111x

MS4520V2-30F switch

Supported in Release 111x

S5560S-EI switch series

S5560S-SI switch series

Supported in Release 612x

S5130S-HI switch series

S5130S-EI switch series

S5130S-SI switch series

S5130S-LI switch series

Supported in Release 612x

S5120V2-SI switch series

S5120V2-LI switch series

Supported in Release 612x

S3100V3-EI switch series

S3100V3-SI switch series

Supported in Release 612x

S5110V2 switch series

Supported in Release 612x

S5110V2-SI switch series

Supported in Release 612x

S5000V3-EI switch series

Supported in Release 612x

S5000E-X switch series

Supported in Release 612x

WAS6000 switch series

Supported in Release 612x

E128C switch

E152C switch

E500C switch series

E500D switch series

Supported in Release 612x

MS4520V2 switch series (except the MS4520V2-30F switch)

Supported in Release 612x

MS4320V2 switch series

MS4300V2 switch series

MS4320 switch series

MS4200 switch series

Supported in Release 612x

WS5850-WiNet switch series

Supported in Release 612x

WS5820-WiNet switch series

WS5810-WiNet switch series

Supported in Release 612x

 

Restrictions and guidelines

You must globally enable MLD snooping in system view before you enable MLD snooping for a VLAN in VLAN view.

Procedures

1.     Assign an IPv6 address and prefix length to each interface on the routers in the IPv6 PIM-DM domain. (Details not shown.)

2.     Configure an IPv6 unicast routing protocol on the routers in the IPv6 PIM-DM domain. (Details not shown.)

3.     Enable IPv6 multicast routing globally on the routers in the IPv6 PIM-DM domain. (Details not shown.)

4.     Enable IPv6 PIM-DM for the interfaces through which routers connects with each other on the routers in the IPv6 PIM-DM domain. (Details not shown.)

5.     Configure Switch A:

# Enable MLD snooping globally.

<SwitchA> system-view

[SwitchA] mld-snooping

[SwitchA-mld-snooping] quit

# Create VLAN 100, assign GigabitEthernet 1/0/1 through GigabitEthernet 1/0/3 to this VLAN, and enable MLD snooping for this VLAN.

[SwitchA] vlan 100

[SwitchA-vlan100] port gigabitethernet 1/0/1 to gigabitethernet 1/0/3

[SwitchA-vlan100] mld-snooping enable

[SwitchA-vlan100] quit

# Configure GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3 as static router ports.

[SwitchA] interface gigabitethernet 1/0/2

[SwitchA-GigabitEthernet1/0/2] mld-snooping static-router-port vlan 100

[SwitchA-GigabitEthernet1/0/2] quit

[SwitchA] interface gigabitethernet 1/0/3

[SwitchA-GigabitEthernet1/0/3] mld-snooping static-router-port vlan 100

[SwitchA-GigabitEthernet1/0/3] quit

6.     Configure Switch B:

# Enable MLD snooping globally.

<SwitchB> system-view

[SwitchB] mld-snooping

[SwitchB-mld-snooping] quit

# Create VLAN 100, assign GigabitEthernet 1/0/1 and GigabitEthernet 1/0/4 to this VLAN, and enable MLD snooping for this VLAN.

[SwitchB] vlan 100

[SwitchB-vlan100] port gigabitethernet 1/0/1 gigabitethernet 1/0/4

[SwitchB-vlan100] mld-snooping enable

[SwitchB-vlan100] quit

# Configure GigabitEthernet 1/0/4 as a static router port.

[SwitchB] interface gigabitethernet 1/0/4

[SwitchB-GigabitEthernet1/0/4] mld-snooping static-router-port vlan 100

[SwitchB-GigabitEthernet1/0/4] quit

# Configure GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3 as static member ports for IPv6 multicast group FF1E::101 in VLAN 100.

[SwitchB] interface gigabitethernet 1/0/2

[SwitchB-GigabitEthernet1/0/2] mld-snooping static-group ff1e::101 vlan 100

[SwitchB-GigabitEthernet1/0/2] quit

[SwitchB] interface gigabitethernet 1/0/3

[SwitchB-GigabitEthernet1/0/3] mld-snooping static-group ff1e::101 vlan 100

[SwitchB-GigabitEthernet1/0/3] quit

7.     Configure Switch C:

# Enable MLD snooping globally.

<SwitchC> system-view

[SwitchC] mld-snooping

[SwitchC-mld-snooping] quit

# Create VLAN 100, assign GigabitEthernet 1/0/1 through GigabitEthernet 1/0/4 to this VLAN, and enable MLD snooping for this VLAN.

[SwitchC] vlan 100

[SwitchC-vlan100] port gigabitethernet 1/0/1 to gigabitethernet 1/0/4

[SwitchC-vlan100] mld-snooping enable

[SwitchC-vlan100] quit

# Configure GigabitEthernet1/0/2 as a static router port in VLAN 100.

[SwitchC] interface gigabitethernet 1/0/2

[SwitchC-GigabitEthernet1/0/2] mld-snooping static-router-port vlan 100

[SwitchC-GigabitEthernet1/0/2] quit

Verifying the configuration

# Display static router port information for VLAN 100 on Switch A.

[SwitchA] display mld-snooping static-router-port vlan 100

VLAN 100:

  Router ports (2 in total):

    GE1/0/2

    GE1/0/3

The output shows that GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3 on Switch A have become static router ports in VLAN 100.

# Display static MLD snooping group entries for VLAN 100 on Switch B.

[SwitchB] display mld-snooping static-group vlan 100

Total 1 entries.

 

VLAN 100: Total 1 entries.

  (::, FF1E::101)

    Host ports (2 in total):

      GE1/0/2

      GE1/0/3

The output shows that GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3 on Switch B have become static member ports of IPv6 multicast group FF1E::101 in VLAN 100.

# Display static router port information for VLAN 100 on Switch C.

[SwitchC] display mld-snooping static-router-port vlan 100

VLAN 100:

  Router ports (1 in total):

    GE1/0/2

The output shows that GigabitEthernet 1/0/2 on Switch C has become a static router port in VLAN 100.

Configuration files

IMPORTANT

IMPORTANT:

The port link-mode bridge command is available only on the following switches:

·     S6520XE-HI switch series.

·     S5560X-EI switch series.

·     S5500V2-EI switch series.

·     MS4520V2-30F switch.

 

·     Switch A:

#

mld-snooping

#

vlan 100

 mld-snooping enable

#

interface GigabitEthernet1/0/1

 port link-mode bridge

 port access vlan 100

#

interface GigabitEthernet1/0/2

 port link-mode bridge

 port access vlan 100

 mld-snooping static-router-port vlan 100

#

interface GigabitEthernet1/0/3

 port link-mode bridge

 port access vlan 100

 mld-snooping static-router-port vlan 100

#

·     Switch B:

#

mld-snooping

#

vlan 100

 mld-snooping enable

#

interface GigabitEthernet1/0/1

 port link-mode bridge

 port access vlan 100

#

interface GigabitEthernet1/0/2

 port link-mode bridge

 port access vlan 100

 mld-snooping static-group FF1E::101 vlan 100

#

interface GigabitEthernet1/0/3

 port link-mode bridge

 port access vlan 100

 mld-snooping static-group FF1E::101 vlan 100

#

interface GigabitEthernet1/0/4

 port link-mode bridge

 port access vlan 100

 mld-snooping static-router-port vlan 100

#

·     Switch C:

#

mld-snooping

#

vlan 100

 mld-snooping enable

#

interface GigabitEthernet1/0/1

 port link-mode bridge

 port access vlan 100

#

interface GigabitEthernet1/0/2

 port link-mode bridge

 port access vlan 100

 mld-snooping static-router-port vlan 100

#

interface GigabitEthernet1/0/3

 port link-mode bridge

 port access vlan 100

#

interface GigabitEthernet1/0/4

 port link-mode bridge

 port access vlan 100

#

  • Cloud & AI
  • InterConnect
  • Intelligent Computing
  • Security
  • SMB Products
  • Intelligent Terminal Products
  • Product Support Services
  • Technical Service Solutions
All Services
  • Resource Center
  • Policy
  • Online Help
All Support
  • Become A Partner
  • Partner Policy & Program
  • Global Learning
  • Partner Sales Resources
  • Partner Business Management
  • Service Business
All Partners
  • Profile
  • News & Events
  • Online Exhibition Center
  • Contact Us
All About Us
新华三官网